Sign In
Upload
Manuals
Brands
IDEC Manuals
Control Unit
SmartRelay FL1B-M08B2R2
IDEC SmartRelay FL1B-M08B2R2 Module Manuals
Manuals and User Guides for IDEC SmartRelay FL1B-M08B2R2 Module. We have
2
IDEC SmartRelay FL1B-M08B2R2 Module manuals available for free PDF download: User Manual, Manual
IDEC SmartRelay FL1B-M08B2R2 User Manual (336 pages)
Brand:
IDEC
| Category:
Control Unit
| Size: 4.57 MB
Table of Contents
Table of Contents
6
1 Getting Started with IDEC Smartrelay
11
2 IDEC Smartrelay Installation and Wiring
23
Modular IDEC Smartrelay Setup
27
Maximum Setup
27
Setup with Different Voltage Classes
28
Installing/Removing IDEC Smartrelay
29
DIN Rail Mounting
30
Wall-Mounting
34
Wiring IDEC Smartrelay
36
Connecting the Power Supply
37
Connecting IDEC Smartrelay Inputs
39
Connecting Outputs
50
Connecting the as Interface Bus
54
Putting into Operation
56
Switching on the IDEC Smartrelay/Power on
56
Operating States
60
3 Programming IDEC Smartrelay
62
Connectors
64
Blocks and Block Numbers
67
The Way to IDEC Smartrelay, Starting with the Circuit Diagram
70
The Four Golden Rules for Operating IDEC Smartrelay
73
Overview of IDEC Smartrelay Menus
75
Writing and Starting the Circuit Program
76
Select Programming Mode
76
The First Circuit Program
78
Circuit Program Input
79
Assigning a Circuit Program Name
85
Password
86
Switching IDEC Smartrelay to RUN Mode
91
Second Circuit Program
94
Deleting a Block
101
Deleting Block Groups
102
Correcting Programming Errors
103
Selecting Analog Output Values for RUN/STOP Transition
103
Deleting the Circuit Program
105
Summertime/Wintertime Conversion
106
Synchronization
111
Memory Space and Circuit Dimensions
112
4 IDEC Smartrelay Functions
118
Constants and Connectors - Co
119
Basic Functions List - GF
122
And
124
AND with Edge Detection
125
NAND (Not AND)
126
NAND with Edge Detection
127
NOR (Not OR)
129
XOR (Exclusive OR)
130
NOT (Negation, Inverter)
130
Basics on Special Functions
131
Designation of the Inputs
132
Time Response
133
Backup of the Real-Time Clock
134
Retentivity
134
Parameter Protection
134
Calculating the Gain and Offset of Analog Values
135
Special Functions List - SF
138
On-Delay
142
Off-Delay
146
On-/Off-Delay
148
Retentive On-Delay
150
Interval Time-Delay Relay / Pulse Output
152
Edge-Triggered Interval Time-Delay Relay
154
Asynchronous Pulse Generator
157
Random Generator
159
Stairwell Light Switch
161
Dual-Function Switch
164
Seven-Day Time Switch
167
Twelve-Month Time Switch
172
Up/Down Counter
175
Operating Hours Counter
179
Frequency Trigger
184
Analog Trigger
187
Analog Differential Trigger
190
Analog Comparator
194
Analog Value Monitoring
199
Analog Amplifier
202
Latching Relay
205
Current Impulse Relay
206
Message Texts
209
Softkey
216
Shift Register
220
Analog Multiplexer
223
Analog Ramp Control
227
PI Controller
232
5 Configuring IDEC Smartrelay
239
Selecting Parameter Assignment Mode
240
Parameters
242
Selecting the Parameters
243
Modifying Parameters
244
Setting the Default Values for IDEC Smartrelay
247
Setting the Time-Of-Day and Date (FL1D-H12RC
247
Setting the Display Contrast
249
Setting the Start Screen
250
6 IDEC Smartrelay Memory Cartridge (Card)
251
Security Function (Copyprotect)
253
Inserting and Removing the Memory Cartridge (Card)
256
Copying Data from the IDEC Smartrelay to the Memory Cartridge (Card)
258
Copying Data from the Memory Cartridge (Card) to IDEC Smartrelay
260
7 IDEC Smartrelay Software
262
Connecting IDEC Smartrelay to a PC
265
8 Applications
267
Stairway or Corridor Lighting
269
Requirements for a Stairway Lighting System
269
Previous Solution
269
Lighting System with IDEC Smartrelay
270
Special Features and Expansion Options
272
Automatic Door
273
Requirements of an Automatic Door
273
Conventional Solution
274
Door Control System with IDEC Smartrelay
274
Special Features and Expansion Options
277
Extended Solution with FL1D-H12RCC
277
Air-Conditioning System
280
Requirements for an Air-Conditioning System
280
Advantages of Using IDEC Smartrelay
283
Factory Door
285
Requirements for a Gate Control System
285
Previous Solution
286
Extended IDEC Smartrelay Solution
288
Centralized Control and Monitoring of Several Factory Doors
289
Requirements for a Gate Control System
290
Luminous Rows
293
Requirements for a Lighting System
293
Previous Solution
294
Luminous Row Control System with FL1D-H12RCC
295
Service Water Pump
297
Requirements for a Control System of a Service Water Pump
298
Previous Solution
298
Service Water Pump System with FL1D-H12RCC
299
Special Features and Expansions
300
Benefits of IDEC Smartrelay
301
A Technical Data
303
General Technical Data
303
Technical Data: FL1D-H12RCC/FL1D-B12RCC and FL1B-M08C2R2
305
Technical Data: FL1D-H12SND and FL1B-M08B1S2
308
Technical Data: FL1D-H12RCA/FL1D-B12RCA and FL1B-M08D2R2
311
Technical Data: FL1D-H12RCE/FL1D-B12RCE and FL1B-M08B2R2
314
Switching Capacity and Service Life of the Relay Outputs308
318
Technical Data: FL1B-J2B2
319
Technical Data: FL1D-K2B2
320
B Determining the Cycle Time
321
CIDEC Smartrelay Without Display
323
DIDEC Smartrelay Menu Structure
326
E Type Numbers
328
Index
330
Advertisement
IDEC SmartRelay FL1B-M08B2R2 Manual (297 pages)
Brand:
IDEC
| Category:
Control Unit
| Size: 2.86 MB
Table of Contents
Preface
2
Table of Contents
5
1 Getting Started with IDEC Smartrelay
11
2 IDEC Smartrelay Installation and Wiring
21
Setup of the Modular IDEC Smartrelay
23
Maximum Setup
23
Setup with Different Voltage Classes
24
Installing/Removing IDEC Smartrelay
25
Wall-Mounting
30
Wiring the IDEC Smartrelay
32
Connecting the Power Supply
32
Connecting IDEC Smartrelay Inputs
34
Connecting Outputs
42
Switching on the IDEC Smartrelay /Power on
45
3 Programming IDEC Smartrelay
49
Connectors
51
Blocks and Block Numbers
54
The Way to IDEC Smartrelay, Starting with the Circuit Diagram
57
The 4 Golden Rules for the Operation of IDEC Smartrelay
60
Overview of the IDEC Smartrelay Menus
62
Writing and Starting the Circuit Program
63
Select Programming Mode
63
The First Circuit Program
65
Circuit Program Input
66
Assigning a Circuit Program Name
72
Password
73
Switching IDEC Smartrelay to RUN Mode
78
Second Circuit Program
80
Deleting a Block
86
Deleting Block Groups
87
Correcting Typing Errors
88
Deleting the Circuit Program
89
Summertime/Wintertime Conversion
90
Synchronization
95
Memory Space and Circuit Dimensions
96
4 IDEC Smartrelay Functions
102
Constants and Connectors - Co
103
Basic Functions List - GF
106
And
108
AND with Edge Detection
109
Nand (Not And)
110
NAND with Edge Detection
111
Nor (Not Or)
113
XOR (Exclusive OR)
114
NOT (Negation, Inverter)
114
Basics on Special Functions
115
Designation of the Inputs
116
Time Response
117
Backup of the Real-Time Clock
118
Retentivity
118
Parameter Protection
119
Calculating the Gain and Offset of Analog Values
119
Special Functions List - SF
122
On-Delay
126
Off-Delay
130
On-/Off-Delay
132
Retentive On-Delay
134
Interval Time-Delay Relay / Pulse Output
136
Edge-Triggered Interval Time-Delay Relay
138
Asynchronous Pulse Generator
141
Random Generator
143
Stairwell Light Switch
145
Dual-Function Switch
148
Seven-Day Time Switch
151
Twelve-Month Time Switch
156
Up/Down Counter
159
Operating Hours Counter
163
Frequency Trigger
168
Analog Trigger
171
Analog Differential Trigger
174
Analog Comparator
178
Analog Value Monitoring
183
Analog Amplifier
186
Latching Relay
188
Current Impulse Relay
189
Message Texts
192
Softkey
199
Shift Register
203
5 Configuring IDEC Smartrelay
206
Selecting Parameter Assignment Mode
207
Parameters
209
Selecting the Parameters
210
Modifying Parameters
211
Setting the Time-Of-Day and Date (FL1C-12RC
214
6 IDEC Smartrelay Memory Cartridge (Card)
215
Security Function (Copyprotect)
217
Inserting and Removing the Memory Cartridge (Card)
220
Copying Data from the IDEC Smartrelay to the Memory Cartridge (Card)
222
Copying Data from the Memory Cartridge (Card) to IDEC Smartrelay
224
7 IDEC Smartrelay Software
226
Connecting the IDEC Smartrelay to a PC
228
8 Applications
230
Stairway or Corridor Lighting
232
Requirements for a Stairway Lighting System
232
Previous Solution
232
Lighting System with IDEC Smartrelay
233
Special Features and Expansion Options
235
Automatic Door
236
Requirements of an Automatic Door
236
Conventional Solution
237
Door Control System with IDEC Smartrelay
237
Special Features and Expansion Options
240
Extended Solution with FL1C-H12RCC
240
Air-Conditioning System
243
Requirements for an Air-Conditioning System
243
Advantages of Using IDEC Smartrelay
246
Factory Door
248
Requirements for a Gate Control System
248
Previous Solution
249
Extended IDEC Smartrelay Solution
251
Centralized Control and Monitoring of Several Factory Doors
252
Requirements for a Gate Control System
253
Luminous Rows
256
Requirements for a Lighting System
256
Previous Solution
257
Luminous Row Control System with FL1C-H12RCC
258
Service Water Pump
260
Requirements for a Control System of a Service Water Pump
261
Previous Solution
261
Service Water Pump System with FL1C-H12RCC
262
Special Features and Expansions
263
Benefits of IDEC Smartrelay
264
A Technical Data
266
General Technical Data
266
Technical Data: FL1C
268
Technical Data: FL1C-H12SND and FL1B-M08B1S2
271
Technical Data: FL1C
274
Technical Data: FL1C
277
Switching Capacity and Service Life of the Relay Outputs
280
Technical Data: FL1B-J2B2
281
B Determining the Cycle Time
282
CIDEC Smartrelay Without Display
284
DIDEC Smartrelay Menu Structure
287
E Type Numbers
289
Index
291
Advertisement
Related Products
IDEC SmartRelay FL1B-M08B1S2
IDEC SmartRelay FL1B-M08D2R2
IDEC SmartRelay FL1B-M08C2R2
IDEC SmartRelay FL1B-J2B2
IDEC SmartRelay FL1C-H12SND
IDEC SmartRelay FL1C-H12RCE
IDEC SmartRelay FL1C-B12RCE
IDEC SmartRelay FL1C-H12RCA
IDEC SmartRelay FL1D-H12RCC
IDEC SmartRelay FL1D-H12RCE
IDEC Categories
Switch
Controller
Control Unit
Relays
Power Supply
More IDEC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL