Sign In
Upload
Manuals
Brands
HyQuest Solutions Manuals
Data Loggers
iRIS 350FX
HyQuest Solutions iRIS 350FX Manuals
Manuals and User Guides for HyQuest Solutions iRIS 350FX. We have
2
HyQuest Solutions iRIS 350FX manuals available for free PDF download: User Manual
HyQuest Solutions iRIS 350FX User Manual (109 pages)
Brand:
HyQuest Solutions
| Category:
Data Loggers
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Declaration of Conformity
9
2 Introduction
10
About this Basic User Guide
10
Support
10
3 Overview
11
Introduction
11
Features
11
Typical Applications
11
Table 1 - Feature Summary
11
Key Features
12
Terminal Diagnostics
12
Wireless IP Connectivity
12
Alternative Wireless Connectivity (SMS or FTP)
12
Power Management
12
Data Logging
13
Logged Data Array Identification
14
Alarm Processing
14
Real Time Clock & Calendar
14
Security
15
Gateway Communication
15
4 Iris 350X and Iris 350FX Comparison
16
5 Installation
17
Opening / Closing the Housing
17
Removing / Fitting the SIM Card
17
I/O Connector
17
Internal Battery
18
Internal/External 12V Battery Supply
19
External (Charger) Power Supply
19
Analogue I/O
19
Digital I/O
20
6 Configuration
24
Terminal Connection
24
Terminal Security Code
24
Configuration Menus
25
General
25
Power
27
Comms
29
I/O Configuration
37
Table 2 - Digital Output Modes
37
Table 3 - Digital Output Polarity
38
Devices
40
Sensor Configuration
41
Table 4 - Standard Sensor Sources
42
Alarm Configuration
45
Camera Configuration
46
SMS Numbers
47
User Configuration
48
User Messages
49
Lookup Tables
49
Terminal Menus
51
Main Menu
51
7 Operation
54
LED Indicators
54
Status LED
54
Diagnostic Leds
54
LCD & Keypad
54
LCD Operation
54
Table 5 - Status LED Indication Modes
54
Status Icons
55
Display Menu Structure
56
Keypad Buttons
57
Primary LCD Display Screens
57
Sensor Related Screens
59
Totaliser Related Screens
61
Comms Related Screens
62
SMS Communication
65
SMS Text Commands
65
General Hints
66
8 Sensor Connection Examples
67
Introduction to Connection Examples
67
Connecting a Flow Meter or Rain Gauge
67
Connecting a 0-5V Pressure Transducer
69
Connecting a 2-Wire Loop-Powered 4-20Ma Sensor
70
Connecting an Up/Down Water Level Instrument
71
Connecting a Unidata High-Speed Serial Instrument
72
Connecting Analogue Wind Instruments
73
Connecting SDI-12 Instruments
74
Connecting Quadrature Encoders
76
Connecting a Vaisala Wxt5X0 Weather Transmitter
77
Configuration
77
Vaisala Configuration Software Settings
78
Iris Sensor Configuration
79
9 Analogue Input Scaling
80
Example: a 4-20Ma Water Level Sensor
80
10 RS232 Interface Telemetry / Gateway Comms
81
Overview
81
RS232 Port Telemetry
81
RS232 Only Telemetry Mode
81
Table 6 - RS232 Port Telemetry Control
81
Table 7 - RS232 Telemetry Mode Indications
81
Non-Dedicated RS232 Telemetry Mode
82
Gateway Communication
82
Aliased Gateway Explained
83
Gateway Example
83
11 Using Modbus Slave Mode
85
Configuring Iris 350FX to Use Modbus
85
Enabling RS232 Modbus Operation Using Keypad/Lcd
87
12 Troubleshooting
88
Can't Connect to the Iris Via the RS232 Port
88
Iris will Not Start When the Battery Is First Connected
88
Pulse Lost When Iris Connected to Other Equipment
88
Unable to Connect to an IP Network
88
Iris will Not Respond to SMS Requests
88
Iris 350FXV Answers a Voice Call, but no Sound Is Heard
88
Unable to Access Terminal Menu
89
Digital Output Activates When User Is Logged on
89
Sensors Log a "Nan" Value
89
Sensor Values Not Included in SMS Reply to "RQ
89
External 12V Battery Not Charging as Expected
89
13 Appendix A - Specific Information
90
General Characteristics
90
Technical Specifications
91
Antenna Connection
92
Mounting
93
14 Appendix B - Voice Annunciation (Iris 350FXV)
94
Table 8 Voice Partition Details
94
Loading Wave Files into the Iris
95
Audio File Settings
96
Audio Script Settings
96
Uploading Audio Files over a Remote Connection
98
15 Appendix C - Using an Iris-CAM Camera
98
Overview
98
Specifications
98
Mounting
99
Connecting the Iris-CAM
99
Installing PC Based Software & USB Drivers
100
Connecting to the PC
101
Focusing
102
Iris Configuration
102
Installing Iris Software for Camera Support
102
Configure the Camera on the Iris
102
16 Appendix D - Upgrading Firmware/Software
103
Overview
103
File Naming Conventions
103
Iris Executive Firmware
103
Iris Application Software
103
Module Openat
104
Iris Automated Upgrade Procedure (Software/Firmware)
104
Iris Manual Upgrade Procedure (Software/Firmware)
105
17 Appendix E - Sdi-12
107
What Is SDI-12
107
Advantages of SDI-12
107
Electrical Interface
108
Serial Data Line
108
Ground Line
108
Volt-Line
108
18 User Notes
109
Advertisement
HyQuest Solutions iRIS 350FX User Manual (117 pages)
Brand:
HyQuest Solutions
| Category:
Data Loggers
| Size: 10 MB
Table of Contents
Table of Contents
2
I Disclaimer
5
Safety Instructions
6
2 II Safety Instructions
7
Part I Introduction
7
About this Manual
8
Features
8
Typical Applications
9
Key Features
9
Terminal Diagnostics
9
Wireless IP Connectivity
9
Alternative Wireless Connectivity (SMS or FTP)
9
Power Management
10
Data Logging
10
Logged Data Array Identification
11
Alarm Processing
11
Real Time Clock
12
Security
12
Gateway Communication
12
Iris 350X and Iris 350FX Comparison
12
Support
14
Installation
15
Part II
15
Mounting
15
Opening / Closing the Housing
16
Removing / Fitting the SIM Card
16
Antenna Connection
17
I/O Connector
17
Internal Battery
18
Internal / External 12V Battery Supply
18
External (Charger) Power Supply
18
Analogue I/O
18
Digital I/O
20
Sensor Connection Examples
22
Connecting a Flow Meter or Rain Gauge
22
Connecting a 0 - 5 V Pressure Transducer
23
Connecting a 2-Wire Loop-Powered 4 - 20 Ma Sensor
24
Connecting an up / down Water Level Instrument
25
Connecting Analogue Wind Instruments
26
Connecting SDI-12 Instruments
27
Connecting Quadrature Encoders
28
Configuration
30
Part III
30
Terminal Connection
30
Terminal Security Code
31
Configuration Menus
31
General
32
Power
33
Comms
34
I/O Configuration
41
Devices
45
Sensor Configuration
45
Alarm Configuration
51
Camera Configuration
52
SMS Numbers
53
3.3.10 User Configuration
54
3.3.11 User Messages
55
3.3.12 Lookup Tables
55
Terminal Menus
57
Main Menu
57
Using Ilink 2012'S Sensor Configuration Tool
60
Iris Sensor Configuration Example
60
Upgrading Firmware / Software
64
Overview
64
File Naming Conventions
64
Iris Automated Upgrade Procedure (Software/Firmware)
65
Iris Manual Upgrade Procedure (Software / Firmware)
66
Converting Iris 350X to an Iris 350FX
67
Using Modbus Slave Mode
69
Configuring Iris 350FX to Use Modbus
70
Enabling RS232 Modbus Operation Using Keypad / LCD
71
Operation
73
Part IV
73
General Hints
73
LED Indicators
73
Status LED
73
Diagnostic Leds
74
LCD & Keypad
74
LCD Operation
74
Status Icons
75
Keypad
76
Display Menu Structure
76
Keypad Buttons
77
Primary LCD Display Screens
77
Sensor Related Screens
81
Totaliser Related Screens
83
Comms Related Screens
84
SMS Communication
88
SMS Text Commands
88
Analog Input Scaling
89
Example: a 4 - 20 Ma Flow Meter
90
RS232 Interface Telemetry / Gateway Comms
90
Overview
91
RS232 Port Telemetry
91
Gateway Communication
92
Part V Repair
95
Part VI Technical Data
96
Part VII Obligations of the Operator and Disposal
97
Obligations of the Operator
97
Dismantling / Disposal
97
Appendices
99
Part VIII
100
Declaration of Conformity
100
Voice Annunciation (Iris 350FXV)
101
Loading Wave Files into the Iris
102
SMS Control of Digital Outputs
104
Overview
104
Configuration
105
Configuration Example
105
Iridium Satellite Variant
108
Overview
108
Using an Iris-CAM Camera
109
Overview
109
Specifications
109
Mounting
110
Connecting the Iris-CAM
110
Installing PC Based Software & USB Drivers
111
Connecting to the PC
112
Focusing
113
Iris Configuration
113
What Is SDI-12
114
Advantages of SDI-12
114
SDI-12 Electrical Interface
114
Advertisement
Related Products
HyQuest Solutions iRIS 270
HyQuest Solutions iRIS Under Cover
HyQuest Solutions iRIS 150FX
HyQuest Solutions iLevel-GW
HyQuest Solutions ML-IoT/C
HyQuest Solutions ML-IoT/C-IP66
HyQuest Solutions ML-IoT/C-IP66LP
HyQuest Solutions ML-IoT/N
HyQuest Solutions ML-IoT/N-IP66
HyQuest Solutions ML-IoT/N-IP66LP
HyQuest Solutions Categories
Measuring Instruments
Data Loggers
Industrial Equipment
Media Converter
Winches
More HyQuest Solutions Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL