Sign In
Upload
Manuals
Brands
Hettich Manuals
Accessories
HettCube 600 R
Hettich HettCube 600 R Manuals
Manuals and User Guides for Hettich HettCube 600 R. We have
2
Hettich HettCube 600 R manuals available for free PDF download: Operating Manual
Hettich HettCube 600 R Operating Manual (174 pages)
Brand:
Hettich
| Category:
Laboratory Equipment
| Size: 7.24 MB
Table of Contents
Table of Contents
3
Introduction
7
Symbols
7
Symbol on the Shipping Carton Label
10
Personal Protective Equipment
11
Personnel Qualification
11
Intended Use
11
Replacement Parts/Consumable Material
12
Scope of Delivery
12
Return Shipments
13
Safety Information
14
Device Description
16
Standard Device
16
Options
18
Glass Door
18
Additional Device Access Port
19
Independent Pt100 Temperature Sensor with 4-20 Ma Analogue Output
20
Switchboard
20
Continuous Cooling (Option)
20
Passive Dehumidification
21
Accessories
21
Transport and Storage
24
Commissioning
27
Unpacking the Incubator
27
Setting Up, Connecting and Switching on the Incubator
30
Installing the Incubator
30
Incubator Connection
31
Initial Commissioning
35
Inserting and Removing the Slide-In Modules
38
Standard Slide-In Modules
38
Telescopic Slide-In Modules
39
Operation
41
Operating Elements
43
Loading
43
Door Locking Mechanism
44
Fixing the Mechanical Display Protection of the Control Panel
45
Standard Check before Every Use
45
Switching on the Incubator
46
Initialization
46
Operating Modes
47
Functional Description of Standstill Mode
47
Functional Description of Manual Mode
48
Functional Description of Program Mode
49
Main Screen
50
Process Flow Information
52
Manual Mode
54
Manual Mode Settings
54
Starting Manual Mode
66
Manual Mode Changes During Running Operation
67
Program Mode
69
Program Mode Settings
69
Creating a Program
70
Editing a Program
78
Copying and Deleting a Program
81
Program Mode - Start Settings
84
Program Mode Overview
90
Device Settings
93
About
95
Date & Time
95
Temperature
96
Tolerance Band
97
Temperature Guard
98
Control Contact (Option)
101
Language
105
Sound
105
Door
106
Screen
106
Power Failure
108
Failure Alarm
109
Export
109
Import
112
Hours of Operation
114
Logbook
114
System Information
115
Admin Access
115
Service Dashboard
118
Heat Compensation
118
Cleaning, Disinfection and Maintenance
120
Cleaning
121
Disinfection
123
Removal of Radioactive Contaminants
123
Autoclaving
124
Maintenance
124
Troubleshooting
125
Activating the Automatic Circuit Breaker
125
Warnings and Error Messages
126
Door Warning
131
Event Overview
132
Tolerance Band Alarm
132
Temperature Protection, Class 3.1 / 3.2
132
Technical Data
133
Hettcube 200
133
Hettcube 200 R
134
Hettcube 400
136
Hettcube 400 R
137
Hettcube 600
139
Hettcube 600 R
141
Definition of the Utilized Space
143
Type Plate
144
Dimensions
145
Disposal
147
Free and Open Source Software
148
Index
149
13 Appendix
153
A Software Symbols
155
B Examples
159
Temperature Drop During the Entire Weekend (Friday Afternoon to Monday Morning)
159
Temperature Drop over One Day (Sunday)
160
Temperature Drop with Holiday Function (Using Wednesday as an Example)
160
Temperature Drop on the Weekend with Start Delay
161
Temperature Drop on the Weekend Including the Passive Dehumidification Option
162
External Devices Are Integrated in Program Mode, E.g. DAY/NIGHT Simulation
163
Combination of Standstill Mode with Incubation Mode (Energy-Saving Mode)
164
Incubator Is Always Cleaned on Wednesdays Due to the Laboratory Routine (SOP) (Standstill Mode)
165
C Accessory Overview
167
D Declaration of Conformity
171
E List of Standards
173
Advertisement
Hettich HettCube 600 R Operating Manual (173 pages)
Brand:
Hettich
| Category:
Accessories
| Size: 7.28 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Symbols
7
Symbol on the Shipping Carton Label
10
Personal Protective Equipment
11
Personnel Qualification
11
Intended Use
12
Replacement Parts/Consumable Material
13
Scope of Delivery
13
Return Shipments
13
2 Safety Information
14
3 Device Description
16
Standard Device
16
Options
18
Glass Door
18
Additional Device Access Port
19
Independent Pt100 Temperature Sensor with 4-20 Ma Analogue Output
20
Switchboard
20
Continuous Cooling (Option)
20
Passive Dehumidification
21
Accessories
21
4 Transport and Storage
24
5 Commissioning
27
Unpacking the Incubator
27
Setting Up, Connecting and Switching on the Incubator
30
Installing the Incubator
30
Incubator Connection
31
Initial Commissioning
35
Inserting and Removing the Slide-In Modules
38
Standard Slide-In Modules
38
Telescopic Slide-In Modules
39
6 Operation
41
Operating Elements
43
Loading
43
Door Locking Mechanism
44
Fixing the Mechanical Display Protection of the Control Panel
45
Standard Check before Every Use
45
Switching on the Incubator
46
Initialization
46
Operating Modes
47
Functional Description of Standstill Mode
47
Functional Description of Manual Mode
48
Functional Description of Program Mode
49
Main Screen
50
Process Flow Information
52
Manual Mode
54
Manual Mode Settings
54
Starting Manual Mode
66
Manual Mode Changes During Running Operation
67
Program Mode
69
Program Mode Settings
69
Creating a Program
70
Editing a Program
78
Copying and Deleting a Program
81
Program Mode - Start Settings
84
Program Mode Overview
90
Device Settings
93
About
95
Date & Time
95
Temperature
96
Tolerance Band
97
Temperature Guard
98
Control Contact (Option)
101
Language
105
Sound
105
Door
106
Screen
106
Power Failure
108
Failure Alarm
109
Export
109
Import
112
Hours of Operation
114
Logbook
114
System Information
115
Admin Access
115
Service Dashboard
118
Heat Compensation
118
7 Cleaning, Disinfection and Maintenance
120
Cleaning
121
Disinfection
123
Removal of Radioactive Contaminants
123
Autoclaving
124
Maintenance
124
8 Troubleshooting
125
Activating the Automatic Circuit Breaker
125
Warnings and Error Messages
126
Door Warning
131
Event Overview
132
Tolerance Band Alarm
132
Temperature Protection, Class 3.1 / 3.2
132
9 Technical Data
133
Hettcube 200
133
Hettcube 200 R
134
Hettcube 400
136
Hettcube 400 R
137
Hettcube 600
139
Hettcube 600 R
141
Definition of the Utilized Space
143
Type Plate
144
Dimensions
145
10 Disposal
147
11 Free and Open Source Software
148
12 Index
149
13 Appendix
153
A Software Symbols
155
B Examples
159
Temperature Drop During the Entire Weekend (Friday Afternoon to Monday Morning)
159
Temperature Drop over One Day (Sunday)
160
Temperature Drop with Holiday Function (Using Wednesday as an Example)
160
Temperature Drop on the Weekend with Start Delay
161
Temperature Drop on the Weekend Including the Passive Dehumidification Option
162
External Devices Are Integrated in Program Mode, E.g. DAY/NIGHT Simulation
163
Combination of Standstill Mode with Incubation Mode (Energy-Saving Mode)
164
Incubator Is Always Cleaned on Wednesdays Due to the Laboratory Routine (SOP) (Standstill Mode)
165
C Accessory Overview
167
D Declaration of Conformity
171
E List of Standards
173
Advertisement
Related Products
Hettich HettCube 600
Hettich HettCube 200
Hettich HettCube 200 R
Hettich HettCube 400
Hettich HettCube 400 R
Hettich HettCube 60
Hettich 64000-01
Hettich 64005-01
Hettich Steelforce Pro Highline 670 SLS
Hettich 61201-20
Hettich Categories
Laboratory Equipment
Indoor Furnishing
Door Opening System
DC Drives
Drill
More Hettich Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL