Harvard Bioscience 80-6000-51 User Manual (130 pages)
AMINO ACID ANALYSER
Brand:
Harvard Bioscience
| Category:
Laboratory Equipment
| Size: 4 MB
Table of Contents
1 Safety and Regulation
9
Warranty and Liability
6
Table of Contents
9
Intended Use
10
Technical Specification
10
Analytical Performance Characteristics
12
Clinical Performance Characteristics
13
Manufacturer's Details
13
Authorised Representative
14
Electrical Safety
14
Electrical Supply and Fuse Rating
14
Input and Output Connections
14
Installation Requirement
15
Lifting and Carrying
16
Replaceable Parts
16
Warning Signs Used on the Instrument
16
Ventilation
16
Special Considerations
16
Environmental Consideration
16
Chemicals Hazard
17
First Aid
17
Device and Waste Disposal
18
Cleaning and General Care
18
Serious Incidents
18
Basic Operating Principles
18
2 Functional Description
20
Control System
21
Introduction
21
Buffer Supply
23
Fluidics System
23
Ninhydrin Supply
23
Reaction Coil
23
Nitrogen Supply
24
Use of Buffer System
24
3 Fluidics Systems
25
Autosampler
26
Buffer Storage Area
26
Fluidics System
26
General Description
26
Introduction
26
Ninhydrin Reservoir
26
Injection Modes
27
Analytical Column
28
Buffer and Ninhydrin Filters
29
Dual Piston Pumps
29
Pump Assembly
29
Automatic Piston Wash System
30
Buffer Solenoid Valves
30
Back Pressure Valve
31
Coil Flush Device
31
Photometer and Reaction Coil Unit
31
Pre-Wash Column
31
Pressure Transducers
31
Reaction Coil
31
Back Pressure Valve
32
Mixing Manifold
32
Photometer
32
Reaction Coil Pressure Transducer
32
Tubing and Connectors
32
4 Instrument Controls
33
Biosys Control and Data Handling
34
Overview of System Operation
34
Running Biosys Setup
35
Operation Tab
41
Settings Tab
42
About Tab
43
Service Mode Tab
43
Minimized Window
44
The Manual Operation Window
45
The Biosys Programmer Window
47
The Biosys Editor Window
51
The Biosys Fluidics Window
55
The Biosys Utilities
60
Additional Checks before the Start-Up Procedure
62
Automatic Operation
62
Operating the Biosys Software
62
Autosampler Setup
64
Start up Preparation
65
Starting the Sample List
69
Access During the Run
70
Run and Sample Logs
72
Reagent Management System
74
Using the Reagent Management System
74
Standby and Holiday Programs
75
5 Operating Instructions
77
Equipment and Sample Preparation
78
Installation of the Buffers
78
Operating Instructions
78
Initial Buffer Line Bleeding
79
Buffer Change During Routine Operations
81
Bleeding the Buffer Pump
82
Controlling the Nitrogen Pressure into the Buffer Bottles
82
Bleeding the Ninhydrin Pump
83
Pressure Transducers
84
Setting the Buffer and Ninhydrin Flow Rates
84
Bio 30+ Flow Rate Calibration
85
Calibration Procedure
86
Preparing the Ultra Ninhydrin Reagent
87
Ninhydrin Filter Cartridge Replacement
88
Replacing the Ninhydrin Reagent Bottle
88
Photometer
90
Reaction Coil
90
Recorder (Optional)
90
Sample Preparation for Physiological Fluid Analysis
90
Autosampler Operation
91
Bio 30+ Safety Systems
91
Biochrom Physiological Standard
91
Standard Amino Acid Solutions: Preparation
91
Analytical Procedures
92
Initial Checks
92
Setting the Chart Recorder (Optional)
92
Shut-Down Procedure
93
6 Maintenance
95
Daily Checks
96
Preventive Maintenance Schedule
96
Analytical Column
97
Maintenance Procedures
97
Monthly Checks
97
Analytical Column Maintenance
98
Column Headspace
98
Prewash Column
98
Photometer and Reaction Coil
99
Prewash Column Maintenance
99
Flowcell Cleaning
100
Photometer Lamp Maintenance
102
Reaction Coil Cleaning
102
Flangeless Connectors
103
PEEK Fingertight Connectors
103
Tubing and Connectors
103
In-Line Buffer Filter Replacement
104
Ninhydrin Bottle Filter Replacement
104
Replacing the Buffer and Ninhydrin Filters
104
Cleaning the Check Valves
105
In-Line Ninhydrin Filter Replacement
105
Pump Maintenance
105
Replacing Check Valves
106
7 Troubleshooting Chart
108
Analyser Errors
109
Error Messages
109
Introduction
109
Openlab/Ezchrom Errors
111
Reagent Management Errors
111
Autosampler Errors
113
Hardware Errors
113
Fault Conditions
115
Part Number Description
120
Spare Parts
120
APPENDIX A: Buffer Storage
123
APPENDIX B: Standard Programs
123
APPENDIX C: Chart Recorder
124
APPENDIX D: Use of an Integrator
125
APPENDIX E: Optimisation of Chromatography
126
Advertisement
Advertisement
Related Products
Harvard Bioscience 80-6000-50
Harvard Bioscience 80-6000-52
Harvard Bioscience 80-6000-53
Harvard Bioscience 80-6000-53EZ
Harvard Bioscience 80-6000-54
Harvard Bioscience 80-6000-55
Harvard Bioscience 80-6000-56
Harvard Bioscience 80-6000-57
Harvard Bioscience 80-6000-58
Harvard Bioscience 800 2770
Harvard Bioscience Categories
Laboratory Equipment
Medical Equipment
Portable Generator
Amplifier
Racks & Stands
More Harvard Bioscience Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL