H2Scan HY-OPTIMA 2720 Operating Manual (45 pages)
HY-OPTIMA 2700 Series Explosion Proof In-line Hydrogen Process Analyzer
Brand:
H2Scan
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
Chapter 1: Model Specifications and Certifications
6
Description
6
Models
6
Model 2710
6
Model 2720
6
Model 2730
7
Model 2740
7
Specifications
8
Performance Specifications
8
Operating Specifications
8
Analyzer Certifications
9
Dimensions
10
Chapter 2: Installation
11
Opening the Analyzer
11
Wiring
13
AC Power Wiring
15
Relay Wiring
15
Pressure Sensor Wiring (Optional)
15
4-20Ma Interface Wiring
16
Serial Interface Wiring
16
Relays
16
Analyzer Mounting
17
Startup
18
Models 2710, 2730, 2740
18
Model 2720
18
Shutdown
18
Chapter 3: Operation and Configuration
19
Optimum Analyzer Performance
19
Effect of Pressure
19
Calibration Gas Bottle Accuracy
19
Pressure Sensor (Optional)
19
Pressure Sensor Installation
20
Pressure Sensor Configuration
20
Pressure Sensor Installation Troubleshooting
22
Cleaning
22
Analog Output
22
Serial Communication
23
Serial Commands Summary
23
A Command (Relays)
24
CI Command (Calibrate Analog Output)
25
D Commands (Display Product Information)
25
G Command (Go, Stream Data)
25
H Command (Modify H2 Reporting Range)
26
I Command (Modify Analog Output)
26
PS Command (Configure Pressure Sensor)
27
SV Command (User Selectable Averaging)
27
T Command (Data Log)
28
Command (Clear Field Cal)
29
F Command (Perform Field Cal)
29
Display Menus
29
Intrinsically Safe Infrared Remote Control
29
Intrinsically Safe Requirements
29
Navigating the Display Menus
31
Chapter 4: Field Calibration
32
Calibration Interval
32
Calibration Gases
32
Background Gases
32
Calibration Procedure
33
Procedure Using the Remote Control
33
Procedure Using the Serial Interface
36
Clear Field Calibration (Restore Factory Calibration)
36
Chapter 5: Supplemental Information and Troubleshooting
37
Storage
37
Storage Oxidation & Offsets
37
Expected Oxidation Time and Recovery Time
37
Conditioning to Remove an Oxidation Offset
37
Avoiding a Storage Oxidation Offset
38
Sensor Behavior
38
H2 Measurement
38
Inert Backgrounds
38
H2 Detection
38
Diurnal Effect
38
General Troubleshooting
39
Command Terminal Messages
40
Serial Communication Troubleshooting
40
Connections
41
COM Port Number
41
USB Adaptor Device Driver
41
Rebooting
41
Terminal Program
42
Analyzer Command Line
42
Analog Output Troubleshooting
42
Verify the Hydrogen Values
42
Verify the H2 Range
42
Verify the Analog Output
43
Verify the SCADA Analog Input
43
Calibrate the Analog Output
43
Appendix A: Spare Parts
44
Appendix B: Foxterm Setup
45
Advertisement
Advertisement
Related Products
H2Scan HY-OPTIMA 2710
H2Scan HY-OPTIMA 2730
H2Scan HY-OPTIMA 2740
H2Scan HY-OPTIMA 1730
H2Scan HY-OPTIMA 1740
H2Scan HY-OPTIMA 1720
H2Scan HY-OPTIMA 5330 Series
H2Scan HY-OPTIMA 5331
H2Scan HY-OPTIMA 5332
H2Scan HY-OPTIMA 5333
H2Scan Categories
Measuring Instruments
Control Unit
Security Sensors
Remote Control
I/O Systems
More H2Scan Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL