Test Equipment
METRAHIT IM XTRA
Gossen MetraWatt METRAHIT IM XTRA Manuals
Manuals and User Guides for Gossen MetraWatt METRAHIT IM XTRA. We have
2
Gossen MetraWatt METRAHIT IM XTRA manuals available for free PDF download: Operating Instructions Manual
Gossen MetraWatt METRAHIT IM XTRA Operating Instructions Manual (56 pages)
Insulation Tester, Milliohmmeter, TRMS Multimeter, Short-Circuited Coil Tester
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
Addresses
4
Product Support
4
Recalibration Service
4
Repair and Replacement Parts Service Calibration Center* and Rental Instrument Service
4
Safety Features and Precautions
5
Use for Intended Purpose
6
Meanings of Danger Symbols
6
Meanings of Acoustic Warning Signals
6
Operating Overview
7
Connections, Keys, Rotary Switch, Symbols
7
Symbols Used in the Digital Display
7
Symbols Used for Rotary Switch Positions
8
User Interface Symbols in the Following Sections
8
Symbols on the Instrument
8
Initial Startup
9
Battery Pack
9
Mains Module
9
Switching the Instrument on
9
Querying or Setting Operating Parameters - General Setup
9
Info > Version - Check Current Software Version
9
Language >German/English - Selecting the User Interface Language
9
System > Date/Time - Setting Date and Time
9
System > Brightness - Digital Display Brightness
9
System > Display Zeros
10
System > Change Password
10
System > Display Profile - Digital Display View
10
System > Default Settings
11
Switching the Instrument off
11
System > Auto-OFF - Automatic Shutdown
11
Control Functions
12
Help
12
Selecting Measuring Functions and Measuring Ranges
13
Automatic Range Selection
13
Manual Range Selection
13
Quick Measurements
13
Zero Offset / Relative Measurements
13
Display (TFT)
14
Digital Display
14
Analog Display
14
Measured Value Storage - Data Function (Auto-Hold/Compare)
15
Saving Minimum and Maximum Values - "Minmax
16
Measured Value Memory - STORE Function
16
Remote Read-Out and Storage Via the Z270S Probe
16
Remote Read-Out and Storage Via the PC - PUSH/PRINT Function
16
Measurement Data Recording
17
Measurements
20
Enabling Parameter Changes
20
Insulation Resistance Measurement - RISO Function
20
Preparing for Measurement
20
Performing Insulation Measurement
21
Ending the Measurement and Discharging
21
Short-Circuited Coil Measurement - COIL Function
22
Preparing for Measurement
22
Conducting the Short-Circuited Coil Measurement
23
Ending the Measurement and Discharging
24
Absorption Index Measurement - DAR
25
Polarization Index Measurement - PI
26
Voltage Measurement
27
Alternating Voltage and Frequency Measurement V AC and Hz with Selectable Low-Pass Filter
28
Duty Cycle Measurement - Duty AC
29
RPM Measurement - RPM AC
29
Direct and Pulsating Voltage Measurement, V DC and V (AC+DC)
30
Resistance Measurement
31
6.7 Resistance Measurement “”
32
6.6.4 Direct and Pulsating Voltage Measurement, V DC and V (AC+DC)
32
Capacitance Measurement F
32
6.8 Capacitance Measurement F
33
Temperature Measurement with Resistance Thermometer - Temp RTD
33
Temperature Measurement with Thermocouple - Temp TC
34
6.11 Continuity Test
35
6.10 Temperature Measurement with Thermocouple - Temp TC. 34
35
Continuity Test
35
Diode Testing with Constant Current of 1 Ma
35
6.12 Diode Testing with Constant Current of 1 Ma
36
Milliohm Measurement - Rlo (2-Wire Measurement)
36
6.14 Milliohm Measurement - M/4 (4-Wire Measurement)
37
6.13 Milliohm Measurement - Rlo (2-Wire Measurement)
37
Milliohm Measurement - M/4 (4-Wire Measurement)
37
Compensation of Cable Resistance
37
Thermovoltage Compensation
37
Milliohm Measurement with 200 Ma or 20 Ma DC [M]
38
Milliohm Measurement with 1 a Pulsating Measuring Current (Automatic Thermovoltage Correction at 3 300 M)
38
Current Measurement
39
6.15 Current Measurement
40
Direct and Pulsating Current Measurement, Direct Connection, - a DC and a (AC+DC)
40
Alternating Current and Frequency Measurement, Direct Connection, - AAC and Hz
41
Direct and Pulsating Current Measurement with Current Clamp Sensor - ADC and a (AC+DC)
42
Alternating Current Measurement with Current Clamp Sensor - AAC and Hz
43
Measuring Sequences
44
7.1 Bluetooth Interface
46
6.16 Measuring Sequences
46
Interface Operation
46
Bluetooth Interface
46
Wifi Interface
46
Characteristic Values
47
9.1 Displays - Error Messages
51
Maintenance and Calibration
51
Displays - Error Messages
51
Battery Pack
51
9.5 Measurement Cables
52
9.3 Fuse
52
9.2 Battery Pack
52
Fuse
52
Housing Maintenance
52
Measurement Cables
52
Returns and Environmentally Sound Disposal
52
10.1 General
53
9.8 Manufacturer's Guarantee
53
9.7 Recalibration
53
Recalibration
53
Manufacturer's Guarantee
53
Accessories
53
General
53
Technical Data for Measurement Cables (Included with KS17-2 Cable Set and Z270S Probe)
53
Index
54
Advertisement
Gossen MetraWatt METRAHIT IM XTRA Operating Instructions Manual (24 pages)
Brand:
Gossen MetraWatt
| Category:
Multimeter
| Size: 0 MB
Advertisement
Related Products
Gossen MetraWatt METRAHIT Cal
Gossen MetraWatt METRAHIT IM E-DRIVE
Gossen MetraWatt METRALINE RCD CHECK
Gossen MetraWatt METRISO XTRA
Gossen MetraWatt METRISO PRIME+
Gossen MetraWatt METRALINE PAT
Gossen MetraWatt METRACELL BT PRO
Gossen MetraWatt METRALINE MF
Gossen MetraWatt M525B
Gossen MetraWatt M522P
Gossen MetraWatt Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Controller
More Gossen MetraWatt Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL