Manuals and User Guides for Genesis GEN3t. We have
1
Genesis GEN3t manual available for free PDF download: User Manual
Genesis GEN3t User Manual (1124 pages)
Portable Data Recorder
Brand:
Genesis
| Category:
Data Loggers
| Size: 58.82 MB
Table of Contents
Table of Contents
5
About this Manual
19
Symbols Used in this Manual
19
Manual Conventions
20
Introduction
21
Safety Messages
21
FCC and General
24
Grounding
25
Instrument Symbols
27
Categories in Accordance with IEC 61010-2-030:2010
28
Basic Insulation Versus Reinforced
30
Measurement Categories
28
Protection and Isolation
28
Additional Means of Protection for Single Fault Conditions
31
Protection
32
Overvoltage/Current Protection
33
Isolation
33
Environment
34
Laser Safety
35
Manual Handling of Loads
36
International Safety Warnings
37
Operation of Electrical Installations
53
Normative Documents and Declarations
54
Electrical
54
Electrostatic Discharge (ESD)
54
Electro-Magnetic Compatibility (EMC)
55
Environment
57
Environmental Protection
57
CE Declaration of Conformity
58
FCC Class a Notice
59
Batteries
60
Packaging
57
WEEE - Waste Electrical and Electronic Equipment
57
General
60
Removal and Replacement
61
Remove/Replace the Battery from the Backplane
62
Remove/Replace the Battery from the PC Section
64
Recharging
67
Disposal
68
Mains Power
69
Power and Frequency Requirements
69
Connecting Power
70
Fuse Requirements and Protection
72
Fuse Replacement
73
Introducing Gen3T
75
Introduction
75
Mainframe Overview
76
Mainframe Feature Comparison
77
Hardware
79
PCI-E/Cpci Backplane
79
Input Cards
80
Master/Slave Support
80
Thermal Protection
80
Acquisition
82
Statstream
82
Signal Conditioning
84
Data Storage
85
Interface/Controller Section
86
Gen3T Connections
87
Setting up the Gen3T
87
Connecting the GEN Series to a Network
88
Connecting the GEN Series Directly to a PC
89
Default Network Settings
89
Connecting the GEN Series to a Company Network
90
Note on IP Address and DHCP
90
Network Testing and Troubleshooting
92
Restore Default Network Settings
93
Removing and Installing Input Cards
94
Removing Cards
94
Installing Cards
95
Handle
97
Turning the Handle
98
Feet
101
To Turn the Feet out
101
To Turn the Feet in
101
Probe Calibration
102
DC Power Output
104
Digital Event/Timer/Counter
106
Isolated Event Adapter
110
Torque/Rpm Adapter
111
Getting Started
114
Gen3T Control
114
Connecting Gen3T to Perception
116
Acquisition and Storage
121
Introduction
121
Recording
122
Storage
123
More on Sweeps
124
Pre-Trigger Sweeps
125
More on Continuous Data Storage
127
Real-Time Sampling and Time Base
129
Time Base
129
Time Base Settings for Ffts
130
Additional Information
132
10 Digital Trigger Modes
133
Introduction
133
Digital Trigger Detector
134
Understanding Digital Triggering
134
Valid Trigger Conditions
136
Trigger Modes
138
Basic Trigger Mode
138
Dual Trigger Mode
139
Window Trigger Mode
140
Dual-Window Trigger Mode
141
Sequential Trigger Mode
142
Trigger Qualifier
143
Trigger Add-Ons
144
Slope Detector
144
Pulse Detector
145
Hold off
146
Interval Timer
147
Interval Timer - Less
147
Interval Timer - more
148
Interval Timer - between
149
Interval Timer - Notbetween
150
Event Counter
151
Recorder and System Trigger
152
Channel Alarm
154
11 Interface/Controller
155
Introduction
155
Communication and Control
156
Network Protocols and Ports
157
Using the 1 Gbit Option Connections
158
Master/Slave Synchronization
159
Connecting Multiple Mainframes Using the Master/Slave Card
163
Connecting the Master/Slave Synchronization Connector
163
Setting the Master/Slave Operating Modes
166
Setting the Master/Slave Trigger
168
Synchronizing a Master/Slave Setup to External Time Sources
171
I/O Connector
172
I/O Connector Input Overvoltage Protection
173
I/O Connector Functions and Connector Pinning
174
Network Attached Storage (NAS) Using Iscsi
178
Introduction: Iscsi NAS with GEN DAQ Network
178
External Storage Setup Dialog - Perception
179
TCP/IP Connection to a NAS
179
GEN Data Acquisition System
180
Iscsi Host
181
Iscsi Target
181
Target Name (IQN)
182
What Is CHAP
182
How to Format the Iscsi
184
Status Messages/ Troubleshooting
184
Set up an Iscsi NAS Connected through an Ethernet Switch
185
Set up an Iscsi NAS Connected Without an Ethernet Switch
189
Set up an Iscsi NAS Connected to a Corporate Network - Basic Setup
193
Set up an Iscsi NAS Connected to a Corporate Network - Advanced Setup
197
Option - Solid State Drive (SSD) 1-G073-2
202
Option - Optical 1 Gbit Ethernet Interface
208
Option - 10 Gbit Ethernet Interface
210
Installing a 1 Gbit SFP/10 Gbit SFP+ Module
217
Introduction
217
Warnings
217
Installation Steps
219
Option - IRIG and IRIG/GPS Time Synchronization
223
GPS Antenna System Rules
224
Rule 1: Antenna Placement
224
Rule 2: Is a GPS Line Amplifier Needed
225
Rule 3: Lightning Arrestors
225
Rule 4: Interconnect Cables
226
Option - Ethercat
227
Ethercat® Generic Principles
228
Ethercat® Slave Stack
229
Data Link Layer
230
Physical Layer
230
Application Layer
232
Real-Time Formula Database
234
Setting up Ethercat® Channels in Genesis
234
Selecting the Appropriate Ethercat® Configuration
235
Static Mode
236
Dynamic Mode
238
Coe Object Layout
239
Ethercat® Timing Aspects
240
More Ethercat® Timing Aspects
241
Aligning Ethercat® Latencies over Multiple Mainframes
242
Ethercat® Interfacing
243
Supported Ethercat Masters
243
Troubleshooting
246
12 Input Cards
247
Available Input Cards
247
Acquisition Card Feature Comparison
250
Isolated 1Kv Input Cards
251
GN610B, Isolated 1Kv 2Ms/S Input Card with Real-Time Formula Database
251
GN611B, Isolated 1Kv 200Ks/S Input Card with Real-Time Formula Database
252
GN610, Isolated 1Kv 2Ms/S Input Card
253
GN611, Isolated 1 Kv 200Ks/S Input Card
254
Using the GN610/GN611 and GN610B/GN611B
255
Understanding the GN610/GN611 and GN610B/GN611B Category Rating
259
Understanding the GN610/GN611 and GN610B/GN611B Input
260
Using the High Precision Differential Probe
262
Measuring Currents
264
GN610/GN611, GN610B/GN611B Isolation and Type Testing
265
Channel to Chassis Isolation Test
267
Channel to Channel Isolation Test
269
High Potential Test
271
Engineering Tests
273
GN610/GN611 and GN610B/GN611B Input Overload Protection
274
GN610/GN611, GN610B/GN611B Protection Mechanisms
274
Overvoltage and Current Protection
274
Thermal Monitor of the Input Channels
276
Thermal Shutdown in Critical Conditions
277
Restore Range Selected by User Automatically
278
Isolated Basic/Iepe Cards
279
GN815, Isolated Basic/Iepe 2Ms/S Input Card
279
GN816, Isolated Basic/Iepe 200Ks/S Input Card
280
Using the GN815 and GN816
281
Understanding the GN815 and GN816 Isolation
283
Understanding the GN815 and GN816 Input
284
Characteristics Per Channel
285
Using Probes
285
GN815 and GN816 Input Overload Protection
286
Restore Range Selected by User Automatically
287
Thermal Monitor of the Input Channels
287
Thermal Shutdown in Critical Conditions
288
GN410 and GN411 Bridge Input Cards
289
Bridge Amplifier Configuration
289
Bridge Completion
291
Input Connectors
291
Shunt Calibration
291
Shielding and Driven Guard
292
Various Bridge Configurations
293
Bridge Connector Reference Card
296
Bridge Completion
297
Configuring and Using the Bridge Amplifier
297
Bridge Completion - Full (4/4) Bridge
298
Bridge Completion - Half (1/2 or 2/4) Bridge
299
Bridge Completion - Quarter (1/4) Bridge
301
Excitation
303
Shunt Verification - Setup
307
Shunt Verification - Procedure
309
Bridge Balance
311
GN440 and GN441 Universal Amplifier Input Cards
313
GN412 and GN413 High Speed - Differential Input Cards
314
High Resolution Universal Input Card
315
GN840/GN1640 Universal 500 Ks/S 8/16 Channel Input Cards
315
Basic Mode and Cabling
317
Supported Sensor Modes
317
Bridge Mode and Cabling
318
Basic Sensor and Cabling
320
Integrated Electronic Piezoelectric (IEPE) Mode and Cabling
321
Piezoelectric (Charge) Mode and Cabling
322
Resistive Temperature Detectors (RTD) Mode and Cabling
323
Current Loop Mode and Cabling
324
Thermocouple Mode and Cabling
325
DIN Rail Breakout
326
Flexible Wiring
329
High Resolution IEPE and Charge Input Cards
330
GN3210 IEPE and Charge 250 Ks/S Input Card
330
GN3211 Basic 20 Ks/S Input Card
331
GN401 Optical Fiber Isolated 100 Ms/S Input Card
333
Binary Marker Cards
334
GN6470 Binary Marker Card
334
GN4070 Binary Marker HV Card
335
Connector Pinning GN6470 and GN4070
336
GN6470 and GN4070 Input Block Diagram
337
GN6470 and GN4070 Counter Mode Pinning
338
GN6470 and GN4070 Frequency (RPM) Mode Pinning
339
GN6470 and GN4070 Quadrature (Position) Mode Pinning
340
Configure the Timer/Counters in Perception
342
To Activate Channel 8 or Channel 9 in Perception
342
GN4070 Connectors and Pinning
346
13 Option Cards
347
Option Carrier Card (OCC)
347
Option Cards Supported
348
Integration Card
349
14 GEN Series Synchronization Methods
356
Architecture
356
Ptp
356
PTP Technology Background(1)
356
PTP Protocol Details
357
Best Master Clock Algorithm (BMC)
358
PTP Switch Types
360
Switches Using Boundary Clocks
361
End-To-End Transparent Clocks
362
One-Step and Two-Step Clock Synchronization
362
Transparent Clock Switch Synchronization
364
Peer-To-Peer Transparent Clocks
362
Switches Using Transparent Clocks
362
Message-Based Synchronization
364
Switch Delays
367
Common Terms Used in IEEE
368
GEN Series Synchronization Methods Compared
370
Signal Phase Shift Synchronization
370
Trigger Synchronization
371
Absolute Time of Day Synchronization
373
Start/Stop Synchronization
374
Synchronization Specification Overview
376
15 Understanding Inputs and Usage of Probes
378
GEN Series Inputs
378
Single-Ended Input
379
Balanced Differential Input
381
Isolated Single-Ended or Isolated Unbalanced Differential Input
382
Isolated Balanced Differential Input
384
GEN Series Voltage Probe Types
386
Passive, Single-Ended Voltage Probes
387
Passive, Single-Ended Isolated Voltage Probes
390
High Accuracy Passive, Single-Ended Isolated Voltage Probes
392
Passive, Differential Matched Isolated Voltage Probes
394
Active Differential Voltage Probes
396
LDS Probe Part Number Reference Table
397
Probe Accessories
398
Probes Master List
399
Probe Bandwidth Calibration
400
Probes
400
Probes
402
Probes and Differential Measurements
403
Current Shunt Measurements
404
A Specifications
405
B3772-3.1 en (Gen3T Portable Data Recorder)
405
B2629-2.1 en (GEN Series GN401)
423
A.2 B2629–2.1 en (GEN Series GN401)
423
B2633-2.1 en (GEN Series GN410)
440
A.3 B2633–2.1 en (GEN Series GN410)
440
B2639-2.1 en (GEN Series GN411)
458
A.4 B2639–2.1 en (GEN Series GN411)
458
B2627-2.1 en (GEN Series GN412)
477
B4160-1.1 en (GEN Series GN413)
492
B2631-2.0 en (GEN Series GN440)
506
B2631-2.0 en (GEN Series GN441)
521
B3618-4.2 en (GEN Series GN610)
537
B4374-1.2 en (GEN Series GN610B)
560
B3716-4.2 en (GEN Series GN611)
589
B4375-1.1 en (GEN Series GN611B)
611
B3997-1.1 en (GEN Series GN815)
638
B3998-1.1 en (GEN Series GN816)
657
B4170-1.0 en (GEN Series GN840B, GN1640B)
675
B3240-3.1 en (GEN Series GN3210)
718
B3264-3.1 en (GEN Series GN3211)
743
B3246-1.0 en (GEN Series GN4070)
761
B3245-1.0 en (GEN Series GN6470)
765
B Options, to be Ordered Separately
768
Batteries and Battery Chargers
768
Rechargeable Li-Ion SM202 Battery
768
Li-Ion Battery Charger
769
Breakout Cables and Panels
770
Breakout Cables
770
B.2.2 Breakout Panels
772
Breakout Panels
772
DIN Rail Breakouts
773
16 Pin LEMO Connector Pack
775
B.3 Bridge Articles
775
Bridge Articles
775
Bridge Completion Pack
775
B.4 Burden Resistor
776
Burden Resistor
776
High Precision Burden Resistor
776
Artificial Star Adapter
777
B.5 Card Adapters
777
Card Adapters
777
Artifical Star Adapter Wiring Diagram
778
BNC to Banana Adapter
778
Master Output Card
779
Option Carrier Card Extensions
779
Option Carrier Card
781
IRIG and GPS Card
782
10Gbit Ethernet Card, Optical
784
10Gbit Ethernet Card, Electrical
785
B.6.6 Ethercat® Card
786
Ethercat® Card
786
AC/DC Current Clamp I30S
787
B.7 Current Clamps
787
Current Clamps
787
AC Current Clamp SR661
789
AC Current Clamp M1V-20-2
791
Current Transducers
792
Current Transducers and Accessories
792
Connection Cable LEM CT to MCTS
793
Power Supply for Current Transducer
794
Current Transducer (CT) Wire Diagram
795
Fiber Optic Cables and Sfps
796
Heavy Duty Fiber Optic Duplex Cable
796
Standard Fiber Optic Duplex Cable
796
Heavy Duty Fiber Optic Duplex Patch Cable
797
Standard Zipcord Fiber Optic Duplex Multi Mode Patch Cable
798
Standard Zipcord Fiber Optic Duplex Single Mode Patch Cable
799
Heavy Duty Fiber Optic Duplex Single Mode Cable
800
Gbit Optical Network SFP Module 1310 Nm
801
Gbit Optical Network SFP Module 850 Nm
801
10 Gbit Optical Network SFP Module 1310 Nm
802
Local Storage
803
B.10 Local Storage
803
Mainframe Adapters
804
B.11 Mainframe Adapters
804
G070A Torque/Rpm Adapter
804
G072 Isolated Digital Event Adapter
817
Isolated Digital Event Adapter to Marker Card Cable
827
Measurement Cables
828
B.12 Measurement Cables
828
Shielded 2 Wire 600 V RMS CAT II Cable
828
Test Leads and Clips
829
Rack Mount Kit
830
Removable Solid State Drive (SSD)
831
Solid State Drive
831
B.15 Shipping Case
832
Shipping Case
832
B.16 Software
833
Software
833
Voltage Probes
834
Free Viewer
833
Instrument Panel Languages
833
Perception Professional
833
Perception Standard Software
833
PNRF Free Viewer
833
B.17 Voltage Probes
834
Passive, Single-Ended Voltage Probes
834
Passive, Single-Ended Isolated Probes
839
Passive, Differential Matched Isolated Voltage Probes
840
Active, Differential Voltage Probe
843
High Precision Differential Probe
844
C Maintenance
846
Preventive Maintenance
846
Preventive Drive Replacement
847
Hard Disk Drive
847
Solid State Drive (SSD)
847
Cleaning
849
C.3 Cleaning
849
D Service Information
850
General - Service Information
850
Calibration/Verification
851
D.2 Calibration/Verification
851
E Trouble Shooting
852
Gen3T Is Not Detected
852
Embedded Software Upgrades
857
Boot Recovery Switch
857
Unexpected Mainframe Shutdown
860
The Master/Slave Connection Does Not Synchronize
861
The IRIG/GPS Does Not Synchronize
862
Optical Network (SFP)
863
Master/Slave Synchronization Verification Procedure
864
F Rack Mount Instructions
867
Mount Gen3T in a 19-Inch Rack
867
GPTP Synchronisation
869
Mainframe PTP Connections
869
Gen2I and Gen5I (no PTP Support)
869
Gen7T and Gen16T
869
Gen7I
870
G.1.3 Gen7I
870
Gen7Ta
871
G.1.4 Gen7Ta
871
Gen3I and Gen3T
872
Gen17Ta
873
G.1.6 Gen17Ta
873
Perception Settings
874
Gen7T/Gen16T - Perception Settings
874
G.2 Perception Settings
874
Gen3I, Gen7I, Gen3T, Gen7Ta and Gen17Ta - Perception Settings
875
Synchronizing GEN Series and Quantumx Using PTP
876
Gen3I/Gen7I with Single Quantumx "B" Version Module
876
Gen3I/Gen7I with Single Somatxr "B" Version Module
877
Gen3I/Gen7I with up to Three Quantumx "B" Version Modules
878
Background Network Details
878
G.3.4 Gen3I/Gen7I with Standard Network Switch and Four or more of Quantumx "B" Version Modules
879
Gen3I/Gen7I with PTP Network Switch and Four or more of Quantumx "B" Version Modules
881
Gen3T/Gen7Ta/Gen17Ta with Single Quantumx "B" Version Module
882
Gen7Ta with Multiple Quantumx "B" Version Modules
883
Gen7T/Gen16T with Single Quantumx "B" Version Module
884
Gen7T with Multiple Quantumx "B" Version Modules
885
Genesis and Quantumx Setup Using IRIG-To-PTP Bridge
886
G.3.11 PTP Grandmasters
887
GPS to PTP Bridge
887
IRIG or GPS to PTP Bridge
887
PTP Grandmasters
887
PTP Capable Switch
888
Using PTP and Master/Slave in Combined Setup
889
PTP Configuration Errors
890
H Application Specific Usage
891
Rotational External Clock
891
GEN DAQ Settings Explained
891
Memory and Time Base
893
Mainframe
893
Calculation Example
895
Perception Display Settings Explained
896
Cylinder Pressure Analysis Option Package
898
Cylinder Pressure Analysis Customer Evaluation
899
Cylinder Pressure Analysis and TDC Settings
899
Dy/Dt Triggering
900
H.2 Dy/Dt Triggering
900
External Start/Stop on Digital Event/Timer/Counter Connector
904
Calculating Maximum Fiber Cable Length
908
Wake on LAN Support (WOL)
910
Locating Gen3I and Gen7I Mac/Physical Address
912
Locating Gen3T, Gen7Ta and Gen17Ta Mac/Physical Address
914
Configuring an Encoder with Direction and Reset
916
From Encoder to Level Converter
916
From Level Converter to Digital I/O Connector on the Mainframe
919
Activate Digital I/O Channels with Perception
919
External Clock Divider
895
Calculating Sample Limits for External Time Base Use
895
Recorder/Time Base Groups
895
To Activate Channel 8 or Channel 9 in Perception
922
I Disk Storage Technology
928
Most Used RAID Modes
928
RAID 0 - Striping
930
I.1.1 RAID 0 – Striping
930
RAID 1 - Mirroring
931
I.1.2 RAID 1 – Mirroring
931
RAID 5 - Striping with Parity
932
I.1.3 RAID 5 – Striping with Parity
932
RAID Level 10 - Combining RAID 0 & RAID
933
Setting up the Iscsi Target Using Synology® NAS
934
JBE3200 USB to Optical RS232 Convertor
948
Re-Programming of the USB-RS232 (Opt. 650Nm) Converter to Work with BE3200
948
K Legacy Information - Input Cards
950
Basic Amplifier Non-Isolated Input Cards
950
GN810 Basic 200Ks/S Input Card
950
GN811 Basic 1Ms/S Input Card
951
GN812 Basic ISO 1Ms/S Input Card
952
Basic Extended Isolated Amplifier Card
953
GN813 Basic XT ISO 1 Ms/S Input Card
953
GN814 Basic XT ISO 200Ks/S Input Card
954
Optional G041 1Kv DC Probe
955
Optional G042 1Kv AC Probe
957
High Resolution IEPE and Charge Input Cards
960
GN1610 250 Ks/S Input Card
960
GN1611 Basic 20 Ks/S Input Card
962
Master/Slave Card (G040)
964
Master/Slave Card Operations
965
LED Indicators
967
Installing and Removing the Master/Slave Card
970
Connecting the Master/Slave Card
978
Example of a Master/Slave Configuration (Legacy)
979
Using Legacy and New Mainframes in Master/Slave Setup
980
Connecting Multiple Mainframes Using the Master/Slave Card (Legacy)
980
L Legacy Information - Specifications
984
B2632-3.1 en (GEN Series GN810)
984
B2640-3.1 en (GEN Series GN811)
999
B2634-3.1 en (GEN Series GN812)
1014
B2635-4.1 en (GEN Series GN813)
1030
B2889-5.1 en (GEN Series GN814)
1046
B3240-3.1 en (GEN Series GN1610)
1061
B3264-3.1 en (GEN Series GN1611)
1085
M Rohs Compliance Overview
1105
GEN DAQ Mainframes - Restriction of Hazardous Substances Directive (Rohs) Status
1105
GEN DAQ Acquisition Cards - Restriction of Hazardous Substances Directive (Rohs) Status
1107
GEN DAQ Optical Cables - Restriction of Hazardous Substances Directive (Rohs) Status
1109
GEN DAQ Probes - Restriction of Hazardous Substances Directive (Rohs) Status
1110
GEN DAQ Current Clamps - Restriction of Hazardous Substances Directive (Rohs) Status
1111
Advertisement
Advertisement
Related Products
Genesis Gen 750
Genesis GENAIO10
Genesis GENAIO15
Genesis GENAIO25
Genesis GEN2AIO10
Genesis GEN2AIO20
Genesis GEN2AI025
Genesis GEN2AIO30
Genesis GenWatch3 GW RSP25
Genesis Categories
Automobile
Keyboard
Mouse
Speakers
Headsets
More Genesis Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL