Sign In
Upload
Manuals
Brands
GeminiBio Manuals
Laboratory Equipment
ORFLO Moxi V
User Manuals: GeminiBio ORFLO Moxi V Equipment
Manuals and User Guides for GeminiBio ORFLO Moxi V Equipment. We have
1
GeminiBio ORFLO Moxi V Equipment manual available for free PDF download: User Manual
GeminiBio ORFLO Moxi V User Manual (108 pages)
Brand:
GeminiBio
| Category:
Medical Equipment
| Size: 23 MB
Table of Contents
Table of Contents
3
Introduction
6
About the User Guide
6
Conventions Used in the User Guide
7
Safety Precautions
7
Electrical Safety
7
Laser Safety
8
Biological Safety
8
Moxi V™ System Overview
10
Moxi Vtm Accessories
12
Getting Started
13
General Guidelines
13
Additional Materials Required
14
Using the Moxi V
15
Home (Start) Screen
16
Settings
17
Fluorescence Gain
17
Date and Time
17
Auto Noise-Find
18
Auto Gate Settings
18
Idle Shutdown Timer
18
Password Expiration
18
Secure Mode
18
Sample Preparation Considerations
18
Running a Test
20
Instructions - Cell Count (Size + Viability), PBMC Check, CAR T Expansion Tests
20
Inserting a Cassette
20
System Calibration
20
Loading a Sample
21
"Cell Qc" Test
23
Cell QC - Single Run
24
Cell QC - Start Batch
25
Cell QC - Initial Test Output (both Single Run and Batch)
26
Cell QC - Test Output - Continuing Batch Testing
28
Cell QC - Batch Run - Saved Data and .CSV Summary File
29
Cell QC - "Add to Existing Batch
30
Test Results
30
Recorded Channels
30
Data Display Formats - General Output Types
31
Fluorescence Vs Size Scatter Plot
32
Histograms
34
Reading Raw Data Output (Conc., Size, MFI, and %)
36
Fluorescence Vs. Size Scatter (Dot) Plot
36
Single Channel Histogram Plot
37
Simplified Output and Auto-Gating Overview
37
"Pbmc Check" Output
38
"CAR-T Expansion" Output
40
Cell QC" - Output (both Single Run and Batch)
41
Analyzing/Gating the Data
43
(General) Recommended Post-Test Workflow
44
Re-Scaling the X Axis (Size Range)
44
Gating the Data
45
Overview
45
Size Gating of Scatter (Dot) Plots
47
Fluorescent Gating of Scatter (Dot) Plots
48
Noise Gating of Scatter (Dot) Plots
49
Store and Recall of Gate Settings
50
Histogram Overlays on Fluorescence Vs Size Scatter Plots
51
"Size Histogram" Assay
51
Changing Display Axis for Tests (Fluorescence Vs Size, Histogram Only Views)
54
File/Test Operations
56
Test Naming and Renaming Tests
56
Saving and Deleting Data/Tests
56
Exporting Data Screenshots
57
Editing Saved Tests
58
Compare/Overlay Saved Tests
60
Exporting Data - Connecting Via USB (USB On-The-Go)
63
Connect The Moxi V
63
TM to a Computer
63
Put the Moxi V TM in USB Connect Mode
64
Safely Disconnect Moxi V
66
TM from the Computer
66
Moxi Vtm Help and System Information
66
Moxi Vtm Apps
67
Cfr Part 11 Operation ("Secure Mode")
69
Overview
69
Activating Secure Mode (21 CFR, Part 11 Compliant Mode)
69
Secure Mode - Key Settings
71
Idle Shutdown Timer
72
Password Expiration
72
Secure Mode
72
System Login
72
User Administration
73
Adding a User
73
User Roles
75
Modifying Users
76
Deleting Users
77
Running Tests - Secure Mode
78
Saving Data
78
Electronic Signature
78
File Save Formats
80
FCS Data
80
BMP File
80
Reviewing Data - Secure Mode
81
System Event Logging - Secure Mode
84
Log File Naming
85
Logged System Events
85
Backing up / Transferring Data - Secure Mode
86
Test-Files Directory
86
Users Directory
86
Instrument Firmware and Software Upgrades
87
Upgrade Instructions
87
DATA (Μsd) DISK FORMAT (STRONGLY RECOMMENDED)
88
Moxi V - Tray Insert Replacement Procedure
91
Background
91
Ordering Information
91
Removing an Existing Insert
91
Installing an Insert
92
Troubleshooting
94
Maintenance and Storage
99
Specifications for the Moxi V
102
And Cassettes
102
Ordering Information
104
Technical and Customer Service
104
Warranty
105
Applicable Patents
106
Advertisement
Advertisement
Related Products
GeminiBio Orflo Moxi GO II
GeminiBio MXG102
GeminiBio MXG402
GeminiBio Categories
Laboratory Equipment
Medical Equipment
More GeminiBio Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL