Sign In
Upload
Manuals
Brands
Gantner Manuals
Data Loggers
Q.brixx A109
Gantner Q.brixx A109 Manuals
Manuals and User Guides for Gantner Q.brixx A109. We have
2
Gantner Q.brixx A109 manuals available for free PDF download: Manual, Quick Start Manual
Gantner Q.brixx A109 Manual (106 pages)
Brand:
Gantner
| Category:
Control Unit
| Size: 5.06 MB
Table of Contents
Table of Contents
3
1 Safety Information
7
Intended Use
7
Checking for Damage in Transit
7
Personnel
7
Special Risks
8
Siting Locations
8
Modifications
8
Servicing and Cleaning
9
Disposal
9
General Hazards Due to Non-Observance of the Safety Information
9
2 Labels and Warning Information
10
Warning Information
10
Labels on the Modules
10
Labels in this Manual
11
3 Introduction
13
The Documentation in the Q.brixx Family
14
About this Manual
14
System Description
15
4 Connection
17
Connecting the Power Supply
17
Connecting Interfaces
18
Connecting Q.gate Via Ethernet to a PC/PLC
18
Using the RS-232 Interface of Q.gate
19
Synchronization of Several Systems
21
Connection of a Radio Receiver for Time Signals
23
Connection of a GPS Receiver
24
Module Flashing Frequency
24
Sos
24
Firmware Download
24
FPGA Download
25
Problems During Data Transmission
25
LED Displays in Normal Operation
25
The Modules and Their Connection Options
26
Q.brixx A101: Connecting Sensors and I/O
28
Voltage
28
Current
29
Potentiometer
29
Resistance, Pt100, Pt1000
29
Thermocouple
30
Full and Half-Bridge Transducers
30
Strain-Gauge Quarter Bridges
31
IEPE/ICP ® Sensor
31
Digital Input and Output
32
Q.brixx A102: Connecting Sensors and I/O
33
Voltage
33
Current
34
Full and Half-Bridge Transducers
34
Strain-Gauge Quarter Bridges
35
IEPE/ICP ® Sensor
35
Analog Output
35
Digital Input and Output
36
Q.brixx A104: Connecting Sensors
37
Voltage
38
Thermocouple
38
Q.brixx A106: Connecting Sensors and I/O
39
Full and Half-Bridge Transducers
39
Strain-Gauge Quarter Bridges
40
Inductive Full and Half Bridges
40
Lvdt, Rvdt
41
Analog Output
41
Digital Input and Output
42
Q.brixx A107: Connecting Sensors
43
Voltage
44
Current
45
Potentiometer
45
Resistance, Pt100, Pt1000
45
Thermocouple (Only with Terminal Version)
46
Full-Bridge Transducer
46
Strain-Gauge Half and Quarter Bridges
47
Q.brixx A108: Connecting Sensors and I/O
49
Voltage
50
Current
50
Digital Input and Output
50
Q.brixx A109: Connecting I/O and Outputs
51
Digital Input and Output, Plug 1
51
Analog Output, Plug 2
52
Q.brixx A123: Connecting Sensors
53
Voltage
54
Current
54
Q.brixx A124: Connecting Sensors
55
Voltage
56
Thermocouple
56
Q.brixx A128: Connecting Sensors
57
Voltage
58
Q.brixx D101: Connecting I/O
59
Digital Input and Output
59
Q.brixx S104: Supply Module
62
Replacing a Module
63
Replacing/Changing the Module Type
64
5 Configuration
67
Installing the Test.commander
68
Using Test.commander
69
Linking Test.commander Via Ethernet (TCP/IP)
69
Test.commander and the Serial (Service) Interface
70
Creating a Project for Configuration
71
Setting Sensor Parameters
73
Specifying Digital Input/Outputs
76
Defining Analog Outputs
78
Defining Computations
80
Specifying the Alarm Monitoring
81
Q.gate Settings
82
Slave Interface
83
Host Interface
83
Settings
84
System Variable
86
Virtual Variable
87
Online Tools
90
Read Data Buffer (with Measurements)
90
Displaying Measurements
90
Reading Module Information
91
Reading Status Information
92
Firmware Update
93
Firmware Update for a Test Controller
93
Firmware Update for Modules
94
6 Functional Procedures
95
Ethernet on the PC
95
Finding the IP Address and Subnet Mask of the PC
95
Setting the IP Address on the PC
96
Allowing Access to Network Devices (Firewall)
98
Connecting Sensors with Sensing Leads
100
Sensor Scaling
101
Scaling of Stress Signals and Strain-Gauge Bridges
101
Scaling of Strain Gauges
102
Current Measurement with an External Shunt
103
Measuring with Thermocouples
104
Advertisement
Gantner Q.brixx A109 Quick Start Manual (77 pages)
Brand:
Gantner
| Category:
Data Loggers
| Size: 4.24 MB
Table of Contents
Table of Contents
1
System Preparation
4
Introduction
4
Software Requirements
4
Software Downloads
4
PC Requirements
4
Accessories
4
System Assembly (Q.brixx 1)
5
Description
5
Assembling the Modules
7
DIP Switch Configuration
12
Power Supply
15
Sensor Connections
16
Standard Terminal Blocks
16
Special Connectors
16
Special Terminal Blocks
17
Synchronizing Multiple Q.brixx Controllers
18
Q.brixx Controllers
19
Connections
19
System Assembly (Q.brixx2)
21
PC Configuration
24
Firewall
25
IP Address
25
Starting Test.commander
27
Applying the License & New Project
27
Slave Setup
29
Firmware Updates
32
Connecting to the Hardware
36
Configuring a Controller
38
Controller's Sample Rate (Q.station)
38
Controller's Sample Rate (Q.gate)
40
PAC Functionality Activation/Deactivation
42
UART Configuration
43
Life Signal (Q.station Only)
44
Interfaces (Q.station)
45
Synchronization Source
45
Channel Configuration
48
Real Variables
48
Virtual Variables
55
Naming Variables in Batches
61
Data Logger Configuration - Q.station
66
Rules
66
Sample Rate Assignment
67
Apply Sample Rate to Measurement Modules
69
Accessing Logger Configuration
69
Project Verification
70
System Check
70
Viewing & Saving Live Data
72
Exporting Projects
75
Contact Information
77
Advertisement
Related Products
Gantner Q.brixx A101
Gantner Q.brixx A104
Gantner Q.brixx A103
Gantner Q.brixx A108
Gantner Q.brixx A107
Gantner Q.brixx A116
Gantner Q.brixx A106
Gantner Q.brixx A128
Gantner Q.brixx Series
Gantner Q.brixx1
Gantner Categories
Locks
Control Unit
Touch terminals
IP Access Controllers
Measuring Instruments
More Gantner Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL