Sign In
Upload
Manuals
Brands
Gantner Manuals
Measuring Instruments
Q.bloxx A111
Gantner Q.bloxx A111 Manuals
Manuals and User Guides for Gantner Q.bloxx A111. We have
1
Gantner Q.bloxx A111 manual available for free PDF download: Manual
Gantner Q.bloxx A111 Manual (150 pages)
Brand:
Gantner
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Table of Contents
3
1 Safety Information
9
Intended Use
9
Checking for Damage in Transit
9
Personnel
9
Special Risks
10
Siting Locations
10
Modifications
10
Servicing and Cleaning
10
Disposal
11
General Hazards Due to Non-Observance of the Safety Information
11
2 Labels and Warning Information
13
Warning Information
13
Labels on the Modules
13
Labels in this Manual
14
3 Introduction
15
The Documentation in the Q.bloxx Range
16
About this Manual
16
System Description
17
Operating the Modules Via Q.gate
17
Operating the Modules Via Q.pac
19
Operating the Modules Without Test Controller
20
4 Connecting the Modules
21
Connecting the Base
21
Hot Swap (Factory Setting)
22
Setting the Address (Optional)
23
Activating the Terminating Resistances
24
Mounting/Removing Bases
25
Q.bloxx Extension Socket QES
26
Connecting the Power Supply
28
Fitting and Removal of Modules from Bases
30
Connecting Interfaces
31
Connecting Modules to Q.gate
31
Connecting Modules to Q.pac
32
Connecting Q.gate/Q.pac Via Ethernet to a PC/PLC
34
Using the RS-232 Interface of Q.gate or Q.pac
35
Connecting Modules Directly to a PC/PLC
36
Synchronization of Several Systems
38
Connection of a Radio Receiver for Time Signals
41
Connection of a GPS Receiver
41
Module Flashing Frequency
42
SOS, Configuration Error
42
Firmware Download
42
Activating the Firmware Download
42
Problems During Data Transmission
43
LED Displays in Normal Operation
43
The Modules and Their Connection Options
44
Q.bloxx A101: Connecting Sensors and I/O
46
Voltage
46
Current
47
Potentiometer
47
Resistance, Pt100, Pt1000
47
Thermocouple
48
Full and Half-Bridge Transducers
48
Strain-Gauge Quarter Bridges
49
IEPE/ICP ® Sensor
49
Digital Input and Output
50
Q.bloxx A102: Connecting Sensors and I/O
51
Voltage
51
Current
52
Full and Half-Bridge Transducers
52
Strain-Gauge Quarter Bridges
53
IEPE/ICP ® Sensor
53
Analog Output
53
Digital Input and Output
54
Q.bloxx A103: Connecting Sensors and I/O
55
Voltage
55
Current
56
Digital Input and Output
56
Q.bloxx A104: Connecting Sensors
57
Voltage
57
Thermocouple
58
Q.bloxx A105: Connecting Sensors
59
Resistance, Pt100, Pt1000
59
Q.bloxx A106: Connecting Sensors and I/O
61
Full and Half-Bridge Transducers
61
Strain-Gauge Quarter Bridge
62
Inductive Full and Half Bridges
62
Lvdt, Rvdt
63
Analog Output
63
Digital Input and Output
64
Q.bloxx A107: Connecting Sensors
65
Voltage
65
Current
66
Potentiometer
66
Resistance, Pt100, Pt1000
66
Thermocouple
67
Full-Bridge Transducer
67
Strain-Gauge Half and Quarter Bridges
68
Q.bloxx A108: Connecting Sensors and I/O
69
Voltage
69
Current
70
Digital Input and Output
70
Q.bloxx A109: Connecting I/O and Outputs
71
Digital Input and Output, Plug 1
71
Analog Output, Plug 2
72
Q.bloxx A111: Connecting Sensors and I/O
73
Voltage
73
IEPE/ICP ® Sensor
74
Q.bloxx A116: Connecting Sensors
75
Full and Half-Bridge Transducers
78
Strain-Gauge Quarter Bridge
79
Activating the Shunt Resistance
81
Q.bloxx A123: Connecting Sensors
83
Voltage
84
Current
84
Q.bloxx A124: Connecting Sensors
85
Voltage
86
Thermocouple
86
Q.bloxx A127: Connecting Sensors
87
Voltage
88
Current
88
Q.bloxx A128: Connecting Sensors
89
Voltage
90
Q.bloxx D101: Connecting I/O
91
Digital Input and Output
91
Q.bloxx D104: Connecting Digital Inputs
94
Digital Input
94
Q.bloxx D105: Connecting Digital Outputs
96
Digital Output
96
Q.bloxx D107: Connecting Digital Inputs
97
Digital Input
97
5 Configuration
101
Installing the Test.commander
102
Using Test.commander
103
Linking Test.commander Via Ethernet (TCP/IP)
103
Test.commander and the Serial (Service) Interface
105
Creating a Project for Configuration
106
Configuring Analog Inputs
107
Setting Sensor Parameters
107
Carrier Frequency Synchronization (Q.bloxx A106)
109
Zero Balancing/Taring the Sensor
110
Sensor Scaling over Several Points (Table)
112
Specifying Digital Inputs/Outputs
114
Configuring Analog Outputs
116
Defining Computations
118
Specifying the Alarm Monitoring
119
Q.gate and Q.pac Settings
121
Module Interface
121
Host Interface
122
Settings
122
Storage Settings (Only Q.pac)
125
System Variable
125
Virtual Variable
126
Online Tools
129
Read Data Buffer (with Measurements)
129
Displaying Measurements
129
Reading Module Information
130
Reading Status Information
131
Firmware Update
132
Firmware Update for Test Controller
132
Firmware Update for Modules
133
6 Functional Procedures
135
Using Serial Interfaces
135
Interface Converter
135
Bus Termination on the Q.bloxx Modules
136
Connection Technology
136
Network Topologies
137
Ethernet on the PC
138
Finding the IP Address and Subnet Mask of the PC
138
Setting the IP Address on the PC
139
Allowing Access to Network Devices (Firewall)
141
Connecting Sensors with Sensing Leads
143
Sensor Scaling
144
Scaling of Voltage Signals and Strain-Gauge Bridges
144
Scaling Strain Gauges
145
Current Measurement with an External Shunt
147
Measuring with Thermocouples
148
7 International Sales and Service
149
Advertisement
Advertisement
Related Products
Gantner Q.bloxx A102
Gantner Q.bloxx A105
Gantner Q.bloxx A124
Gantner Q.bloxx A127
Gantner Q.bloxx A123
Gantner Q.bloxx A101
Gantner Q.bloxx A104
Gantner Q.bloxx A107
Gantner Q.bloxx A106
Gantner Q.bloxx A108
Gantner Categories
Locks
Control Unit
Touch terminals
IP Access Controllers
Measuring Instruments
More Gantner Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL