Manuals and User Guides for Fukuda Denshi FCP-2155. We have
1
Fukuda Denshi FCP-2155 manual available for free PDF download: Service Manual
Fukuda Denshi FCP-2155 Service Manual (136 pages)
Interpretive Electrocardiograph
Brand:
Fukuda Denshi
| Category:
Medical Equipment
| Size: 3 MB
Table of Contents
Chapter 2 Circuit Description
16
Table of Contents
16
Introduction
17
Floating Input Circuit
19
Buffer Amplifier
19
Middle Amplifier
21
Amplifier Control and Interface
23
Peripheral A/D Converter Circuit 2-S
24
Clock & Backup Memory
24
Serial Port
25
Motor Control Circuit
26
Sensor Circuit
27
CPU·GA Circuit
27
LCD Control Circuit
28
Thermal Print Head Control Circuit
28
Power Supply Circuit with Charging Circuit
29
Outline of the System
29
Rectifier/Smoothing and On/Off Control Circuits
29
AC Operation
29
On/Off Control Circuit
29
And + 5VA Generator
30
5VA Generator
30
Generator
31
Isolated Power Circuit
32
S Charging Circuit
33
Chapter 3 Troubleshooting
36
Internal Power Supplies
37
Faulty Power Supplies Vs. Effects
38
No Specified Power Supplies Are Available in AC Operation
39
No Specified Power Supplies Are Available in DC Operation
39
Troubles and Countermeasures
39
Floating 5VFD Is Not Output
40
Is Not Output
40
Floating 5VFB Are Not Output
41
Floating ± 5VFA Are Not Output
41
Troubles in Charging Operation
41
LCD Does Not Operate Normally
43
No Key Operation Is Available
43
Chart Paper Is Not Driven or Driven Abnormally
44
Mark on Z-Fold Paper Is Not Detected
44
Buzzer Does Not Sound
45
No Waveform and Alphanumeric Data Are Recorded
45
Paper End Is Not Detected or "PAPER END" Alarm Is Always on Display
45
Programmed Settings Change (Clock Goes Wrong)
45
All 12-Lead Waveforms Are Recorded as Baselines
46
Lead-Off Detection Is Not Available for All Leads
46
No DC Input Waveform Is Recorded
46
Some Lead Waveform Is Recorded as Baseline
46
Lead-Off Detection Is Not Available for some Specific Lead
47
System Error (Code 24) Is Generated at Power-Up
47
Chapter 5 Periodical Inspection
59
Checking Lead Cable and Power Cord
60
Cleaning the Equipment
60
Periodical Inspection
60
Self-Test and Total Function Check
60
Visual Inspection
60
Battery Check
61
Measuring Leakage Current
61
Safety Inspection
61
Measuring Protective Grounding Resistance
64
Remarks
65
Chapter 9 Structural Diagrams
116
Fcp·2155 (Ce)
119
PCB-6410 Assembly 424-3584
119
Main PC Board Assembly 423-3585
120
Upper Case Assembly 423-3586
121
Lower Case Assembly
124
Overall Assembly
125
External Appearance
126
External Appearance (1) 413-0876
126
Upper Case Assembly 423-3322
128
Lower Case Assembly (1) 423-3323
129
Lower Case Assembly (2) 422-3324
130
Lower Case Assembly (3) 422-3325
131
Overall Assembly
132
External Appearance
133
Advertisement
Advertisement
Related Products
Fukuda Denshi FCP-7101
Fukuda Denshi CARDIMAX FX-7202
Fukuda Denshi FX-2111
Fukuda Denshi FX-7102
Fukuda Denshi CardiMax FX-8322
Fukuda Denshi CardiMax FX-8322R
Fukuda Denshi FX-7302
Fukuda Denshi FX-9800
Fukuda Denshi FX-7542
Fukuda Denshi FC101
Fukuda Denshi Categories
Medical Equipment
Monitor
Transmitter
Measuring Instruments
Control Unit
More Fukuda Denshi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL