FPI CEMS-2000 Series Gas Analyzer manual available for free PDF download: User Manual
FPI CEMS-2000 Series User Manual (133 pages)
Gas Analysis System
Brand:
FPI
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Important Notice
2
General Infomation
2
Standards
2
Caution and Warning Information
3
Delivery and Transportation
3
Warranty and Maintenance
4
Technical Support
4
Declaration
4
Table of Contents
5
Compliance and Safety Information
14
Compliance Information
14
Product Safety
14
Immunity
14
Emissions
15
Safety Information
16
Overview
16
Conventions Used
16
General Requirements
17
Electricity Safety
18
High Voltage
18
Power Cable
19
Tools
19
Drilling
20
Thunderstorm
20
Electrostatic
21
Fuse
21
Ultraviolet Light
21
Hot Surface
22
Miscellaneous
22
Lifting Heavy Objects
22
Sharp Objects
22
Binding Signal Lines
22
System Introduction
23
Standards
23
System Features
23
Main System Parameters
24
System Composition
27
Fig 2-1 CEMS-2000 System Architecture (On-Site Mode)
28
Fig 2-2 CEMS-2000 System Architecture (Extraction Mode)
28
Gaseous Pollutants Monitoring Sub-System
29
Sampling Pre-Processing System
29
OMA-2000 Spectroscopic Gas Analyzer
30
Fig 2-3 CEMS-2000 System Sampling Process
30
Fig 2-4 Exterior of OMA-2000 Analyzer
30
Particulates Monitoring Sub-System
31
Gas Parameter Monitoring Sub-System
31
Temperature Transmitter
31
Fig 2-5 LDM-100 Laser Dust Meter
31
Pressure Transmitter
32
Flow Rate Transmitter
32
Fig 2-6 Exterior of Temperature Transmitter
32
Temperature/Pressure/Flow Rate Integrated Transmitter
33
Data Acquisition and Processing Sub-System
33
Fig 2-7 Exterior of Flow Rate Transmitter
33
Fig 2-8 Exterior of TPF-100
33
Fig 2-9 Data Acquisition and Processing Sub-System
34
System Operations
35
Operation Areas
35
Fig 3-1 OMA-2000 Spectroscopic Gas Analyzer
35
Preparation of Running System
36
Pre-Checking
36
Power-Up Sequence
36
Fig 3-2 CEMS-2000S Monitoring Software Screen
36
System Calibration
37
High Pressure Adjustment Bottle
37
Fig 3-3 System Power Switches
37
Adjusting the Flow Rate of Standard Gas
38
Zero Adjustment
38
Fig 3-4 High Pressure Gas Bottle
38
Fig 3-5 Zero Adjustment on OMA-2000 Analyzer
39
Fig 3-6 Manual Adjustment
40
Fig 3-7 Zero Adjustment in Process
40
Fig 3-8 Remote Control Menu
41
Fig 3-9 Remote Control Page
41
Fig 3-10 Pre-Zero Adjustment Page
41
Fig 3-11 Calibration Parameter Menu
42
Calibration
43
Fig 3-12 Calibration Parameter Settings
43
Fig 3-13 Zero Adjustment Page on OMA-2000 Analyzer
44
Fig 3-14 Manual Calibration
44
Fig 3-15 Calibration in Progress
45
Fig 3-16 Remote Control Menu
45
Fig 3-17 Remote Control Page
46
Fig 3-18 Pre-Calibration Page
46
Fig 3-19 Calibration Parameter Menu
47
Fig 3-20 Calibration Parameter Settings
47
Purging
48
Operations of OMA-2000 Spectroscopic Gas Analyzer
49
Operation Panel
49
Fig 4-1 Operation Panel of OMA -2000 Optical Fiber Spectrum Analyzer
49
Fig 4-2 Main Page (Input Password)
51
Fig 4-3 Changing Password
52
Fig 4-4 Confirmation of Changing Password
52
Working Modes
53
Startup Mode
53
Fig 4-5 Instrument Working Modes
53
Normal Mode
54
Failure Mode
54
Fig 4-6 Initialization
54
Menu Structure of the System
55
Fig 4-7 Menu Structure
56
Main Page
57
Fig 4-8 Main Page
57
Instrument Setup
58
Fig 4-9 Password Input Page
58
Fig 4-10 Instrument Setup
58
Communication Setup
59
Fig 4-11 Instrument Setup
59
Fig 4-12 Communication Setup
59
Fig 4-13 Baud Rate Setup
60
Instrument Information
61
Fig 4-14 Instrument Address Setup
61
Fig 4-15 Instrument Information
61
Alert Setup
62
Fig 4-16 Alert Setup
62
Parameter Setup
63
Fig 4-17 Parameter Setup 1
63
Fig 4-18 Parameter Setup 2
63
Fig 4-19 Spectrometer Parameter Setup
64
Fig 4-20 Checking Spectrum Strength
64
Fig 4-21 Pressure Parameter Setup
65
Fig 4-22 Temperature Parameter Setup
66
Fig 4-23 Temperature Input Method
66
Fig 4-24 Humidity Parameter Setup
67
Fig 4-25 Flow Rate Parameter Setup
68
Fig 4-26 Temperature Control Setup
68
Time Setup
69
Changing Password
69
Fig 4-27 Time Setup
69
System Purging
70
Fig 4-28 Changing Password
70
Fig 4-29 Confirming Password
70
Fig 4-30 System Purging 1
71
Fig 4-31 System Purging 2
71
Alert Code
72
Gas Setup Page
72
Fig 4-32 Alert Code
72
Zero Adjustment / Calibration
73
Fig 4-33 Gas Setup
73
Fig 4-34 Zero Adjustment / Calibration Setup
74
Fig 4-35 Zero Adjustment
74
Fig 4-36 Zero Adjustment in Progress
75
Fig 4-37 Calibration
75
Composition Parameter
76
Fig 4-38 Manual Calibration in Progress
76
Fig 4-39 Composition Parameter Setup
76
Density Alert
77
Unit Setup
77
Fig 4-40 Density Alert Setup
77
Fig 4-41 Unit Setup
78
Operations of CEMS-2000 Monitoring Software
79
Fig 5-1 Main Menu and Main Window
80
System Management
81
Logon
81
Fig 5-2 System Management
81
Fig 5-3 User Logon
81
Logout
82
Changing Password
82
Fig 5-4 User Logout
82
Fig 5-5 Changing User Password
82
Fig 5-6 Changing Administrator Password
82
System Logs
83
Fig 5-7 System Logs
83
Log Configuration
84
Fig 5-8 Opening Log File
84
Fig 5-9 Displaying System Log
84
Fig 5-10 System Log Configuration
85
Options
86
Exiting System
86
Fig 5-11 Options
86
Fig 5-12 Exiting System
86
System Configuration
87
Communication Setup
87
Fig 5-13 System Configuration Menu
87
Fig 5-14 Communication Setup
87
Fig 5-15 COM Port Configuration
88
Fig 5-16 Remote Output Configuration
89
Fig 5-17 Configuration of Single-Channel GPRS Output
90
Fig 5-18 Selecting Variables
90
Fig 5-19 Selected Variables
91
Fig 5-20 Configuration of Multi-Channel GPRS Output
92
Data Configuration
93
Fig 5-21 Configuration of TCP/IP Output
93
Fig 5-22 Data Configuration Menu
93
Fig 5-23 System Constant Configuration
94
Fig 5-24 Configuration of Default Measurement Range
95
Fig 5-25 Configuration of Smoothness Times
96
Fig 5-26 Configuration of Alert Threshold
96
Fig 5-27 Configuration of Alert Threshold
97
Fig 5-28 System Prompt 1
97
Fig 5-29 System Prompt 2
97
Fig 5-30 Configuration of Linear Coefficient
98
Fig 5-31 Configuration of Fixed Value
99
Fig 5-32 Configuration of Display Unit
99
Naming of Measuring Point
100
Fig 5-33 Data Configuration During Instrument Maintenance
100
Fig 5-34 Naming of Measuring Point
100
Filling History Data
101
Fig 5-35 Filling Missing Data
101
Fig 5-36 Prompt of no Data Missing
101
System Configuration Information
102
Fig 5-37 Progress of Filling Missing Data
102
Fig 5-38 System Configuration Information
102
Instrument Management
103
Instrument Information
103
Fig 5-39 Displaying System Configuration Information
103
Fig 5-40 Instrument Status
103
Fig 5-41 Temperature and Pressure of Gas Room
104
Fig 5-42 Instrument Information
104
Instrument Parameter
105
Fig 5-43 Alert Parameter
105
Fig 5-44 Calibration Parameter
106
Fig 5-45 Purging Parameter
107
Fig 5-46 Correction Coefficient
108
Fig 5-47 Measurement Range of the Gas
108
Fig 5-48 Gas Measurement Parameters
109
Fig 5-49 Alert Threshold of Gas Density
110
Fig 5-50 Alert Parameter of Gas Room
110
Instrument Control
111
Fig 5-51 Temperature and Pressure Parameters of Gas Room
111
Instrument Alert
112
Fig 5-52 Remote Control
112
Fig 5-53 Checking Current Alerts
113
Fig 5-54 Searching History Alerts
113
Fig 5-55 Alert Configuration
114
Fig 5-56 Adding Alert Level
114
Fig 5-57 Selecting the Alert Level
115
Fig 5-58 Editing Alert Level
115
System Report
116
Report Searching
116
Fig 5-59 Deleting Alert Level
116
Fig 5-60 Daily Report
117
Fig 5-61 Monthly Report
118
Fig 5-62 Quarter Report
118
Graphic Report
119
Fig 5-63 Annual Report
119
Fig 5-64 Daily Report Curve
119
Fig 5-65 Operations to the Curve
120
Fig 7-65 Page Settings
121
Fig 5-67 Printing
121
Fig 5-68 Displaying Point Data
122
Fig 5-69 Monthly Report Curve
123
Fig 5-70 Quarter Report Curve
123
History Data
124
Fig 5-71 Annual Report Curve
124
Fig 5-72 History Data
124
Report Settings
125
Fig 5-73 Report Settings
125
System Help
126
Fig 5-74 Parameters in Report Settings
126
Fig 5-75 System Prompt
126
User Manual
127
About the System
127
Fig 5-76 Help Menu
127
Fig 5-77 User Manual
127
Window
128
Fig 5-78 about the System
128
Fig 5-79 Layout of View
128
Maintenance
130
Alert Information and FAQ
131
Alert Information
131
Frequently Asked Questions
133
Advertisement
Advertisement
Related Products
FPI CI2700
FPI Categories
Indoor Fireplace
Remote Control
Stove
Measuring Instruments
Pellet stove
More FPI Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL