Sign In
Upload
Manuals
Brands
Fotona Manuals
Measuring Instruments
M031-3A
Fotona M031-3A Measuring Instruments Manuals
Manuals and User Guides for Fotona M031-3A Measuring Instruments. We have
1
Fotona M031-3A Measuring Instruments manual available for free PDF download: Service Manual
Fotona M031-3A Service Manual (94 pages)
Brand:
Fotona
| Category:
Measuring Instruments
| Size: 4.54 MB
Table of Contents
Table of Contents
4
Specifications
9
Laser
9
General
10
Functional Diagram Description
12
Mains Inlet and Auxiliary Power Supplies
12
Power Distribution Circuit - Relay Soft Start Board
13
Controller
13
Control Panel with Display Assembly
14
Charger Assembly
14
PFM MODULE Assembly
15
Cooling System Assembly
15
Laser Head Assembly
16
Nd:yag Laser Module
16
1.Polarizer
16
2.Electro Optical Q-Switch
16
3.Λ/4 Plate (Analyzer)
16
KTP Laser Module
16
Simmer Trigger Board
17
Laser Beam Sampling Optics
17
Energy Meter Assembly
17
Beam Sampling Optics
18
Head Control and Safety Shutter Assembly
18
Oven Control PCB
19
Beam Coupling Optics
19
Aiming (Diode) Laser Assembly
19
Laser Beam Delivery
19
Mains Filter a and B
20
Protective Housing
20
Housing
20
Fixed Power Cord
20
Main Circuit Breaker
20
Door Switch Receptacle
20
Foot Switch Receptacle
20
Potential Equalization Terminal
20
Emergency Stop Switch
20
Key Switch
20
Laser Pulse Forming Sequence and Energy Regulation
21
System Wiring Diagram
21
Optical Path Diagram
22
Hand Pieces
22
Dis-Assembly / Replacement
22
Laser Console Covers Removal
22
Removal of the Top Metal Cover
22
Removal of the Metal Side Covers
22
Laser Head Cover Removal
22
Charger Removal/Replacement
23
PFM MODULE Assembly Removal/Replacement
23
Cooling System Removal/Replacement
23
Cooling System Replacement
26
1.Draining Water
26
2.Complete Cooling System Drawer Removal
26
Ionizing Cartridge Replacement
27
Cooling Fans Replacement
27
Relay Board Removal/Replacement
27
Auxiliary Power Supply Assembly Removal/Replacement
27
24VDC Auxiliary Power Supply Removal/Replacement
28
5VDC Auxiliary Power Supply Removal Replacement
28
Controller Removal/Replacement
28
Complete Controller Removal Replacement
28
Replacement of the IC30 EEPROM
29
Replacement of the IC24 (Serial EEPROM)
29
Replacement or Upgrade of System Firmware
30
Laser Module Removal/Replacement
31
Simmer Trigger Board Removal/Replacement
31
Nd:yag Resonator Mirrors Removal/Replacement
31
1.Nd:yag Laser Output Coupler Mirror Removal Replacement
31
Nd:yag Rear Mirror Removal Replacement
31
Nd:yag Laser Pumping Chamber Removal Replacement
32
Nd:yag Laser Flash Lamp Removal/Replacement
32
Laser Rod Replacement
32
Energy Meter Removal/Replacement
33
Head Control and Safety Shutter Removal Replacement
34
Aiming Beam Laser Removal/Replacement
34
Front Panel Removal/Replacement
34
Control Panel Display Assembly Removal and Replacement
34
Incoming Cooling Air Filter Removal/Replacement
35
Using the Built in Service Firmware
35
Service FW Access with System's Front Panel
35
Access to the Service Firmware
36
Changing the Settings in Service Mode
36
Exiting the Service Firmware
37
Use of External Notebook Computer for Advanced Service
37
Setup of External Notebook Computer
37
Connection of External Notebook Computer to the Controller
37
Service Mode with External Notebook Computer
38
Fotona QX MAX System Firmware Parameters
40
1.For Nd:yag Laser
40
2.For KTP Operation
40
Using EPEM Communication Software
41
Connection Problems
41
Laser Parameters Adjustment
41
Safety Measurements
43
Medical Device Type B, Class I Leakage Current Measurement
43
Earth Leakage Current
43
Enclosure Leakage Current Measurement
44
Patient Leakage Current Measurement
44
Medical Device Class I Protective Earth Impedance Measurement
45
General
46
Protective Earth Impedance Measuring Device
46
Measuring Procedure and Conditions
46
Adjustment/Alignment/Calibration Procedures
47
Laser Alignment
47
Complete Laser Alignment
47
Both Laser Mirrors Alignment
47
Rear Mirror Alignment
49
Front Mirror Alignment
50
EOQS Cell and Λ/4 Plate Alignment
51
1.Complete EOQS Cell and Λ/4 Plate Alignment
51
2.Field Service EOQS and Λ/4 Plate Alignment
53
Checking the Laser Alignment (Field Service)
53
Aiming Diode Laser Alignment
55
Nd:yag Beam Alignment
61
KTP Assembly Alignment
66
KTP Beam Alignment
66
KTP Crystal Alignment
68
Energy Meters Calibration Procedure
68
Nd:yag Energy Meters Calibration
69
1.Checking the Q-SW Energy Meter Calibration
69
Nd Q-SW Energy Meter Calibration 1 (Field Service, Preferred)
69
ACC Energy Meter Calibration
70
1.ACC Energy Meter Calibration Test
70
KTP Energy Meters Calibration
71
1.Checking the KTP Energy Meter Calibration
71
2.KTP Energy Meter Calibration
71
Articulated Arm Alignment
72
Tools
72
Aiming Beam Alignment
72
Arm Alignment
74
1.First Mirror Alignment
74
2.Second Mirror Alignment
75
3.Third Mirror Alignment
75
7.Seventh Mirror Alignment
77
Troubleshooting
78
Advisory Messages
78
Advisory Messages During Power-Up
78
Advisory Messages During Self-Test
78
Advisory Messages in Normal Operation
78
Advisory Message in Service Mode
79
Error Messages Reported by the System
79
System Error 10 - Parameters Error
79
System Error 11 - Energy Meter Communication Error
80
System Error 12 - Energy Meter Data Not Available Timeout
80
System Error 13 - Energy Meter Supply Voltage Low
81
System Error 14 - Energy Meter Data Transfer Error CRC Failure
81
System Error 16 - EM1 Data Transfer Error, Wrong Wavelength Read
81
System Error 17 - EM2 Data Transfer Error, Wrong Wavelength Read
81
System Error 18 - Energy Meter Saturation Error
81
System Error 19 (or Five Longer Beeps at Power-On) - Console Communication (I2C) Error
81
System Error 20 - Shutter Blocked in Open Position
81
System Error 21 - Shutter Blocked in Closed Position
82
System Error 22 - Laser Switch Blocked
82
System Error 23 - Laser Switch Blocked
82
System Error 24 - Head Control Error
82
System Error 30 - Cooling Liquid Flow Error
83
System Error 31 - Cooling Liquid Pump Soft Start Circuit Error
83
System Error 32 - Cooling Liquid Overheated or Temperature Switch Error
83
System Error 40 - Simmer Error (Simmer Current Not Present)
83
System Error 50 - Overshoot in Energy (> +20%) of Nd:yag Laser
84
System Error 52 - Missing Laser Pulse
84
Cannot Calibrate Use Lower Settings
85
System Error 56 - under Energy of Nd:yag Laser
85
System Error 57 - under Voltage Limit in Calibration of Nd:yag Laser
85
System Error 58 - Energy Meters Mismatch >30% of Nd:yag Laser
85
System Error 59 - High Q-Switch Leakage
86
System Error 60 - HV Power Supply Error (Charging Time > 2S)
86
System Error 61 - PFM Module Assembly Error (High Voltage Dropped under 120V)
86
System Error 62 - OW1 Control Signal Error
87
System Error 67 - HV Power Supply Relay Error
87
System Error 68 - HV Power Supply, Capacitor Bank Without 24VDC
87
System Error 69 - HV Power Supply Error in Selftest
87
System Error 99 - Program Execution Error
87
Advertisement
Advertisement
Related Products
Fotona M031-3A/2
Fotona M001-13A
Fotona QX MAX
Fotona Categories
Measuring Instruments
More Fotona Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL