FLUXUS G608
Flexim FLUXUS G608 Gas Flow Meter Manuals
Manuals and User Guides for Flexim FLUXUS G608 Gas Flow Meter. We have
1
Flexim FLUXUS G608 Gas Flow Meter manual available for free PDF download: User Manual
Flexim FLUXUS G608 User Manual (244 pages)
Ultrasonic Flowmeter for Gas
Brand:
Flexim
| Category:
Measuring Instruments
| Size: 3.68 MB
Table of Contents
Table of Contents
5
Introduction
11
Regarding this Manual
11
Safety Instructions
11
Warranty
12
Handling
13
First Inspection
13
General Precautions
13
Cleaning
13
Storage
14
Measurement Principle
15
Measurement System
15
Determination of the Volumetric Flow Rate
15
Transmitter
18
Design
18
Status Indication
19
Serial Number
19
Keyboard
20
Selection of the Measuring Point
22
Acoustic Penetration
22
Undisturbed Flow Profile
23
Influence of Noise
26
Selection of the Measuring Point Taking into Account the Flow Profile and the Influence of Noise
28
Installation of FLUXUS G601
30
Location
30
Installation of the Transmitter
30
Connection of the Transducers
32
Power Supply
33
Connection of the Outputs
35
Connection of the Inputs
38
Connection of the Serial Interface
41
Installation of FLUXUS G608
42
Location
42
Installation of the Transmitter
42
Connection of the Transducers
44
Power Supply
45
Connection of the Outputs (Optional)
49
Connection of the Inputs (Optional)
51
Connection of the Serial Interface
53
Mounting the Transducers
54
Preparation of the Pipe Surface
54
Mounting of the Damping Mats
54
Positioning of the Transducers
58
Installation of the Temperature Probe (Optional)
61
Cleaning of the Pipe Surface
61
Installation of the Temperature Probe (Response Time 50 S)
61
Installation of the Temperature Probe (Response Time 8 S)
63
Connection of the Temperature Probe
64
Start-Up
67
Switching On/Off
67
Displays
67
Hotcodes
69
Language Selection
70
Basic Measurement
71
Input of the Pipe Parameters
71
Input of the Medium Parameters
74
Other Parameters
76
Selection of the Channels
76
Defining the Number of Sound Paths
77
Transducer Distance
79
Start of the Measurement
82
Detection of the Flow Direction
83
Stopping the Measurement
83
Displaying the Measured Values
84
Selection of the Physical Quantity and of the Unit of Measurement
84
Toggling between the Channels
85
Adjustment of the Display
86
Status Line
87
Transducer Distance
88
Advanced Measuring Functions
89
Damping Factor
89
Totalizers
89
Upper Limit of the Flow Velocity
91
Cut-Off Flow
92
Uncorrected Flow Velocity
93
Measurement of Highly Dynamic Flows (Fastfood Mode)
94
Calculation Channels
95
Change of the Limit for the Inner Pipe Diameter
98
Data Logger and Transmission of Data
99
Data Logger
99
Transmission of Data
104
Working with Parameter Records
111
Introduction
111
Storing of a Parameter Record
111
Loading of a Parameter Record
111
Deleting Parameter Records
112
Libraries
113
Partitioning of the Coefficient Memory
113
Input of Material/Medium Properties Without the Extended Library
114
Extended Library
116
Deleting a User Defined Material/Medium
119
Arrangement of the Material/Medium Scroll List
120
Settings
122
Time and Date
122
Dialogs and Menus
123
Measurement Settings
126
Settings of the Standard Conditions for the Gas Measurement
127
Setting the Contrast
128
Instrument Information
128
Superuser Mode
129
Activation/Deactivation
129
Transducer Parameters
129
Defining the Flow Parameters
130
Limit of the Signal Amplification
132
Upper Limit of the Sound Speed
133
Number of Decimal Places of the Totalizers
134
Manual Reset of the Totalizers
135
Display of the Sum of the Totalizers
135
Display During the Measurement
135
Wall Thickness Measurement (Optional)
136
Activation of the Wall Thickness Measurement
136
Parameter Input
137
Measurement
138
Inputs
142
Assigning the Temperature Inputs to the Measuring Channels
142
Selection of the Temperature Probe
143
Assignment of Other Inputs to the Measuring Channels
144
Activation of the Inputs
144
Temperature Correction
145
Outputs
147
Installation of an Output
147
Error Value Delay
152
Activation of an Analog Output
153
Configuration of a Frequency Output as a Pulse Output
154
Activation of a Binary Output as a Pulse Output
155
Activation of a Binary Output as an Alarm Output
156
Behavior of the Alarm Outputs
160
Deactivation of the Outputs
162
Troubleshooting
163
Problems with the Measurement
164
Selection of the Measuring Point
165
Maximum Acoustic Contact
165
Application Specific Problems
165
Large Deviations of the Measured Values
166
Problems with the Totalizers
167
Data Transmission
167
A Menu Structure
168
B Technical Data
189
C Reference
226
D Certificates
230
Advertisement
Advertisement
Related Products
Flexim FLUXUS G704
Flexim FLUXUS G709
Flexim FLUXUS G704 A2
Flexim FLUXUS G809
Flexim FLUXUS G801
Flexim FLUXUS G831ST-HT
Flexim FLUXUS G800
Flexim FLUXUS G601
Flexim FLUXUS F704**-NN Series
Flexim FLUXUS F704**-A2 Series
Flexim Categories
Measuring Instruments
Laboratory Equipment
Light Fixture
Transducer
More Flexim Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL