Sign In
Upload
Manuals
Brands
FIRETRACE Manuals
Firefighting Equipment
FK-5-1-12
FIRETRACE FK-5-1-12 Manuals
Manuals and User Guides for FIRETRACE FK-5-1-12. We have
1
FIRETRACE FK-5-1-12 manual available for free PDF download: Design, Installation, Operation, And Maintenance Manual
FIRETRACE FK-5-1-12 Design, Installation, Operation, And Maintenance Manual (102 pages)
FIRE PROTECTION AGENT
Brand:
FIRETRACE
| Category:
Firefighting Equipment
| Size: 7 MB
Table of Contents
Table of Contents
3
Foreword
7
Warnings
7
Safety Precautions
8
Introduction
9
Fire Suppression Agent
9
Cleanliness
9
Thermal Decomposition Products
9
Properties of FK-5-1-12
10
System Description
10
Component Descriptions
11
Fk-5-1-12 Cylinders (100300, 100600, 101200, 120020)
11
Table 1 - FK-5-1-12 Cylinder Dimensions
11
Table 2 - FK-5-1-12 Cylinder Specifications
11
Cylinder Mounting Bracket (100003, 100006, 111206, 111020)
12
Figure 1 - Unit Assembly
12
Table 3 - Unit Assembly Dimensions
12
Cylinder Valves (300112 & 302118)
13
Figure 2 - Cylinder Mounting Bracket Bolt Pattern
13
Table 4 - 940205 Cylinder Mounting Bracket Dimensions
13
Table 5 - 940555 Cylinder Mounting Bracket Dimensions
13
Table 6 - 941055 Cylinder Mounting Bracket Dimensions
13
Table 7 - 942055 Cylinder Mounting Bracket Dimensions
13
Firetrace Detection Tubing (200005)
14
Figure 3 - Cylinder Valves
14
Table 8 - Firetrace Detection Tubing Properties
15
Table 9 - Firetrace Detection Tube Part Numbers
15
Firetrace Detection Tubing Fittings
16
Pressure Gauge (400195)
16
Manual Release (600055)
17
Figure 4 - FK-5-1-12 Pressure Gauge
17
Figure 5 - Manual Release
17
Manual Release Rebuild Kit (600076)
18
Discharge Network
18
Pipe, Fittings, and Pipe Supports
18
Flexible Hoses and Fittings
18
Figure 6 - Flexible Hoses
19
Figure 7 - Flexible Hose Fittings
19
Table 10 - Flexible Hose Part Numbers for 940555/941055/942055 Unit Assembly
19
Nozzles (500015 500120)
20
Figure 8 - Nozzles
20
Table 11 - Flexible Hose Fitting Part Numbers for 940555/941055/942055 Unit Assembly
20
Pressure Switch (400001)
21
Valve Mounted Pressure Switch (940205-PS 940555-PS 941055-PS 942055-PS)
21
Figure 9 - Valve Mounted Pressure Switch
21
Table 12 - Nozzle Part Numbers
21
Figure 10 -Pressure Switch Wiring Schematic
22
Table 13 - Valve Mounted Pressure Switch Part Number
22
Table 14 - Pressure Switch Properties
22
End of Line Pressure Switch (400004)
23
Figure 11 - End of Line Pressure Switch
23
Table 15 - End of Line Pressure Switch Part Number
23
Pressure Switch Assembly (400441)
24
Figure 12 - Pressure Switch Assembly
24
Table 16 -Pressure Switch Assembly Part Number
24
Alarm Module - Battery Operated (600096)
25
Electric Solenoid Assembly (200107 400312 400324 600088)
25
Figure 13 - Alarm Module - Battery Operated
25
Figure 14 - Electric Solenoid Assembly
26
Figure 15 - Electric Solenoid Assembly Wiring Schematic
26
Table 17 - Electric Solenoid Assembly Part Number
26
Table 18 - Electric Solenoid Assembly Properties
26
System Design and Limitations
27
General
27
Specifications
27
Storage and Operating Temperature Range
27
System Operating Pressure
27
Table 19 - Cylinder Pressure-Temperature Relationship
27
Design Procedure
28
Hazard Enclosure Limitations
28
Enclosure Size and Nozzle Limitations
28
Required Amounts of Agent
29
Minimum Design Concentrations
29
Table 20 - Enclosure Size and Nozzle Limitations
29
Table 21 - Class a Minimum Design Concentrations
30
Table 22 - Class B Minimum Design Concentrations
30
Table 23 - Class C Minimum Design Concentrations (3M™ Novec™ 1230, Noah NY5112 & Dukare 1230)
30
Table 24 - Class C Minimum Design Concentrations (Waysmos FK-5-1-12)
30
Table 25 - Class C Minimum Design Concentrations (Chemori 5112™)
30
Actual Concentration
31
Maximum Protected Volume Limitations
31
Class a Fires (All FK-5-1-12 Agents)
31
Class B Fires (All FK-5-1-12 Agents)
31
Table 26 - Class a Fire Enclosure Volume Limitations
31
Table 27 - Class B Fire Enclosure Volume Limitations
31
Class C Fires (3M™ Novec™ 1230, Noah NY5112 & Dukare 1230)
32
Class C Fires (Waysmos FK-5-1-12)
32
Class C Fires (Chemori 5112™)
32
Table 28 - Class C Fire Enclosure Volume Limitations (3M™ Novec™ 1230, Noah NY5112 & Dukare 1230)
32
Table 29 - Class C Fire Enclosure Volume Limitations (Waysmos FK-5-1-12)
32
Table 30 - Class C Fire Enclosure Volume Limitations (Chemori 5112™)
32
Altitude Correction Factor (ACF)
33
Ventilation Shut-Down and Unclosable Openings
33
Pressure Relief Vent Area
33
Table 31 - Atmospheric Correction Factor
33
Nozzle and Discharge Pipe Requirements
34
Discharge Nozzle Limitations
34
Nozzle Area Coverage
34
Table 32 - Nozzle Area Coverage Limitations
34
Discharge Piping and Fitting Specifications
35
Maximum Discharge Piping and Fitting Limitations
35
Table 33 - Discharge Piping Specifications
35
Table 34 - Flexible Discharge Hose Specifications
35
Table 35 - Discharge Pipe Fitting Specifications
35
Discharge Pipe Bends
36
Table 36 - Discharge Piping Limitations
36
Table 37 -Pipe Bend Radius and Equivalent Length
36
Firetrace Detection/Actuation Tubing
37
Figure 16 - Tubing Configuration Guideline (Side View and Top View)
37
Table 38 - Firetrace Detection Tubing Limitations
37
Installation Instructions
38
FK-5-1-12 Cylinder/Valve and Bracket Assemblies
38
Discharge Piping and Nozzles
38
Firetrace Detection Tubing
39
Detection Tubing Fittings and Accessories
39
Firetrace Tubing Cutter (600210)
39
Slip-On Fittings
39
Figure 17 - Firetrace Tubing Cutter 600210
39
End of Line Accessories
40
FDT Charging Using Nitrogen Charge Kit (P/N 600213)
40
System Activation
41
Figure 18 - Firetrace Nitrogen Charge Kit 600213
41
Service and Maintenance Instructions
43
General
43
Periodic Service and Maintenance Procedures
43
Monthly Inspection
43
Semiannual Inspection
44
Five Year Inspection
44
Firetrace Detection Tubing Maintenance
44
Hydrostatic Testing
44
System Dissassembly, Assembly, and Charging
46
Depressurizing the Unit
46
System Recharge
46
Post Discharge
48
Ventilation
48
Remove from Service
48
Appendix A - Parts List
49
Firetrace Fk-5-1-12 Ilp Automatic Suppression Unit Assemblies
49
Cylinder Brackets
49
Accessory Brackets
49
Discharge Network
49
Table 39 - Firetrace FK-5-1-12 ILP Units
49
Table 40 - Cylinder Brackets
49
Table 41 - Accessory Brackets
49
Table 42 - Small ILP Discharge Network Flexible Hoses
49
Table 43 - Medium/Large ILP Discharge Network Flexible Hoses
50
Table 44 - Small ILP Discharge Network Flexible Hose Fittings
50
Table 45 - Medium/Large ILP Discharge Network Flexible Hose Fittings
50
Table 46 - Nozzles
50
Detection Network
51
Table 47 - Firetrace Detection Tubing
51
Table 48 - Tube Fittings
51
Table 49 - End of Line Accessories
51
Miscellaneous
52
Table 50 - Installation Accessories
52
Table 51 - Auxiliary Accessories
52
Table 52 - Installation Tools
52
Table 53 - Valve Accessories
53
Appendix B - Protected Volumes Based on Design Concentrations
54
Classa Fires (All Fk-5-1-12 Agents )
54
Table 54 - Class a Fire Enclosure Volume Limitations for 940205 Unit Assembly
54
Table 55 - Class a Fire Enclosure Volume Limitations for 940555 Unit Assembly
54
Classb Fires (All Fk-5-1-12 Agents )
55
Table 56 - Class a Fire Enclosure Volume Limitations for 941055 Unit Assembly
55
Table 57 - Class a Fire Enclosure Volume Limitations for 942055 Unit Assembly
55
Table 58 - Class B Fire Enclosure Volume Limitations for 940205 Unit Assembly
56
Table 59 - Class B Fire Enclosure Volume Limitations for 940555 Unit Assembly
56
Table 60 - Class B Fire Enclosure Volume Limitations for 941055 Unit Assembly
57
Table 61 - Class B Fire Enclosure Volume Limitations for 942055 Unit Assembly
57
Classc Fires (3M™ Novec ™ 1230, Noah Ny5112 & Dukare 1230)
58
Table 62 - Class C Fire Enclosure Volume Limitations for 940205 Unit Assembly
58
Table 63 - Class C Fire Enclosure Volume Limitations for 940555 Unit Assembly
58
Table 64 - Class C Fire Enclosure Volume Limitations for 941055 Unit Assembly
59
Table 65 - Class C Fire Enclosure Volume Limitations for 942055 Unit Assembly
59
Classc Fires (Waysmos Fk-5-1-12)
60
Table 66 - Class C Fire Enclosure Volume Limitations for 940205 Unit Assembly
60
Table 67 - Class C Fire Enclosure Volume Limitations for 940555 Unit Assembly
60
Table 68 - Class C Fire Enclosure Volume Limitations for 941055 Unit Assembly
61
Table 69 - Class C Fire Enclosure Volume Limitations for 942055 Unit Assembly
61
Classc Fires (Chemori 5112™)
62
Table 70 - Class C Fire Enclosure Volume Limitations for 940205 Unit Assembly
62
Table 71 - Class C Fire Enclosure Volume Limitations for 940555 Unit Assembly
62
Table 72 - Class C Fire Enclosure Volume Limitations for 941055 Unit Assembly
63
Table 73 - Class C Fire Enclosure Volume Limitations for 942055 Unit Assembly
63
Appendix C - Commissioning Document Checklist
64
Appendix D - Safety Data Sheet 3M™ Novec™ 1230 Fire Protection Fluid
65
Appendix E - Safety Data Sheet Waysmos
74
Appendix F - Safety Data Sheet Chemori 5112
79
Appendix G - Safety Data Sheet Dukare 1230
89
Appendix H - Safety Data Sheet Noah Ny5112
96
Advertisement
Advertisement
Related Products
FIRETRACE FSCK
FIRETRACE FTILPINTHTBI
FIRETRACE 898001
FIRETRACE 898002
FIRETRACE 898003
FIRETRACE 920205
FIRETRACE 920505
FIRETRACE 940205
FIRETRACE 940555
FIRETRACE 941009
FIRETRACE Categories
Firefighting Equipment
Security System
Control Unit
More FIRETRACE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL