Sign In
Upload
Manuals
Brands
Förster-Technik Manuals
Pet Care Product
VARIO smart 2.0
User Manuals: Förster-Technik VARIO smart 2.0 Feeder
Manuals and User Guides for Förster-Technik VARIO smart 2.0 Feeder. We have
1
Förster-Technik VARIO smart 2.0 Feeder manual available for free PDF download: Original Service Manual
Förster-Technik VARIO smart 2.0 Original Service Manual (130 pages)
Automatic calf feeder
Brand:
Förster-Technik
| Category:
Pet Care Product
| Size: 6 MB
Table of Contents
Table of Contents
2
Introduction
7
Models
7
Overview of the Automatic Feeder
8
Front and Right Side View of Automatic Feeder
8
Rear View of Automatic Feeder
9
Left Side View of the Automatic Feeder
9
Boiler with Heating Circuit
11
Technical Data
11
Electrical Connection
11
Dimensions
12
Weight
12
Water Connection
12
Boiler
12
Milk Powder Container
13
Number of Feeding Stations and Animals
13
Disposal
13
Symbols
13
Abbreviations
13
Important Safety Instructions
15
Intended Use
15
Required Qualifications
15
Residual Risks
15
How am I Warned of Hazards
17
What Are the Components of a Hazard Description
17
Potentially Fatal Hazards or Health Hazards
17
Material Damage
18
Safety Signs
18
Safety Devices
20
Structural Alterations
21
Commissioning
22
Setting up the Feeder
22
Electrical Connection Provided by the Customer
23
Water Connection
24
Installing Feeding Stations
24
Installing Feeding Station
24
Installing Stand Partitions
25
Attaching the Pushbutton/Remote Control for Manual Feed Start
25
Connecting the Antennas
26
Installing the Antennas
26
Squelch Values and Identification Ranges
27
Connecting Antenna Cables
27
Connecting the Ethernet Cable
28
Installing the Safety Grid for the Powder Hopper Attachment
29
Switching on the Vapor Barrier for Powder Discharge
30
Filling the Powder Container
30
Installing External Cleaning Agent Supply Pipework (Optional)
31
Switching on the Automatic Feeder
33
Setting the Date/Time
33
Filling the Boiler
33
New Installation
33
Setup Settings
34
Adjusting the Calibration Scales
34
Setting Offline Mode
34
Setting Portion
34
Drain Time Station Parameters
35
Function Keys
35
Animal List
35
Checking Components
35
Calibrating Feed Components
35
Checking or Setting Cleaning Settings
35
Cleaning
36
Reading in and Creating Transmitters
36
Registering Animals
36
Entering Correction Days
36
Programming and Control
37
Hand Terminal
37
The Keypad
38
The Auto LED
40
Offline Mode
40
Automatic Mode
40
Menu Structure
40
Symbols
41
Menus
43
Animal Control
43
Main Menu
44
Manual Functions
44
Device Data
44
Setting Operating Modes
44
Checking and Setting Time/Date
46
Setting Portion
46
Drain Time Station Parameters
49
Function Keys
50
Animal List
50
Backing up and Restoring Data
52
Cloud
54
New Installation
55
Software Updates
56
Software Update Via SD Card
56
Software Update Via Cloud
57
Software Update Via Internal (Automatic)
58
Reinstallation
58
Setup
59
Overview of the Setup Menus
60
Language
62
Time/Date
62
Machine
62
Feeder Type
62
Automatic Feeder Number
62
Automatic Feeder Address
63
Feeder Operating Modes
63
Base Size
63
Heating System
64
Boiler Valve
64
Equipment
64
Mixer Drain
64
Additive Dispenser
64
Flushing Agent 1
64
Flushing Agent 2
65
Flushing Agent Sensor
65
Powder Sensor
65
Circulation Valve
65
Gully Valve 2
65
Air Valve
66
Mixer Temperature Sensor
66
Water Meter
66
Supply and Point Electrode
66
Identification
66
ID Chip
67
Calibration Scales
67
Stations
68
Feed
68
Terminal
68
Address
68
Contrast
68
Sleep Mode
68
Communication
69
Printer
69
Network Configuration
69
Cloud
69
Gateway
70
Multireader
70
Restart
70
Calibration
71
Calibrating Without Calibration Scales
71
Calibrating with Calibration Scales
72
Transmitter and Animal Management
75
Managing the Transmitters
75
Basics
75
Creating Transmitter Numbers
75
Reading Transmitter Numbers
76
Manually Entering Transmitter Numbers
76
Assigning Animal Numbers
76
Editing Transmitters or Animal Numbers
77
Deleting the Transmitter Number When Canceling an Animal
78
Calling up the Transmitter Statistics
79
Registering Animals
79
Manual Registration of Animals
79
Automatically Registering Animals
80
Canceling Animals or Animal Groups
81
Canceling Individual Animals
81
Canceling a Group
82
Canceling Weaned Animals
82
Changing the Registration of Animals
82
Shutdown and Recommissioning
83
Shutdown
83
Temporary Shutdown
83
Permanent Shutdown
86
Recommissioning
87
Recommissioning after Temporary Shutdown
87
Recommissioning after Processor Card Replacement
88
Faults and Warnings
90
Faults
90
Calibration Scales
90
Heating up
90
Temperature too High
91
Boiler Not Filled
91
Shortage of Water
91
Water Meter
93
Emptying the Mixer
93
Heating System
94
Boiler Temperature Sensor
95
Calibration
96
ID Chip
96
Station/Drain Valve
97
Uncontrolled Output
98
Warnings
99
Emptying the Mixer
99
Mixer Temperature Sensor
100
Identification
100
Incorrect ID
100
Address Used Twice
100
Unknown Transmitter
101
Calibration
101
Fill up the MP Container
102
Calibration Scales
102
ID Chip
102
Duplicate Animal Number
103
Machine Capacity
104
Check SD Card
104
Other Faults and Messages
105
Automatic Feeder
105
Hand Terminal
105
Boot Loader
106
Service Messages
107
Service Work
107
Diagnosis
108
Checking Valves/Motors
108
Checking the Heating
109
Checking Sensors
110
Calibration Scales
111
Checking Stations
111
Monitoring
111
Version
113
Setup
113
Software
113
Remote Maintenance
113
10. Appendix
114
Checklist for Commissioning and Recommissioning
114
Materials List
119
Shutdown Checklist
120
Standard Feeding Plans
121
CAN Bus Addresses
123
Checking Components for Compliance with National Regulations
125
Index
126
Advertisement
Advertisement
Related Products
Förster-Technik S57.1e
Förster-Technik S21.1e
Förster-Technik TAP5-VS2-50
Förster-Technik Categories
Farm Equipment
Wire Feeders
Water Pump
Commercial Food Equipment
Industrial Equipment
More Förster-Technik Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL