Sign In
Upload
Manuals
Brands
EUTECH INSTRUMENTS Manuals
Measuring Instruments
DO 600
EUTECH INSTRUMENTS DO 600 Manuals
Manuals and User Guides for EUTECH INSTRUMENTS DO 600. We have
2
EUTECH INSTRUMENTS DO 600 manuals available for free PDF download: Instruction Manual
EUTECH INSTRUMENTS DO 600 Instruction Manual (127 pages)
WP 600 Series
Brand:
EUTECH INSTRUMENTS
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
5
General Guide
9
Overview for All Meters
11
About the Meters
11
Display Overview
11
Key Functions
11
Inserting Batteries
12
Inserting Batteries for the First Time
12
Changing Batteries Subsequently
12
Attaching the Belt
13
Connecting Peripherals
14
Probes (Ph/Conductivity/Do)
14
Protective Rubber Boot
15
System Setup Mode for All Meters
16
About Setup Mode
16
Accessing Setup Mode
16
Setup Selection: System Settings
17
Accessing Setup Mode When Password Protection Enabled
23
Modifying Setup Parameters
24
Calibration Mode for All Meters
25
About Calibration
25
About Conductivity/ Resistivity/ TDS/ Salinity Calibration
25
Preparing the Meter for Calibration
25
Accessing Calibration Mode
27
Accessing Calibration Mode When Password Protection Enabled
27
Measurement Mode for All Meters
29
About Measurement Mode
29
Accessing Functions
29
Taking Measurements
30
Prepare the Meter for Measurement
30
Taking a Reading
30
Stable Reading Indicator
31
Holding a Reading
31
Automatic Temperature Compensation (ATC)
31
Manual Temperature Compensation (MTC)
31
Alarm Set Point (for Ph/Conductivity/Do)
32
Calibration Due (CAL-DUE) Indicator (for Ph/Conductivity/Do)
32
Transferring and Printing Data
32
Cybercomm 600 Data Acquisition Software
32
Working with Memory Functions - Auto Data Logging
32
Logging Data Automatically in the Meter's Memory
33
Storing a Current Measurement (in Irda and LED Print Mode: Applicable to All Modes)
33
Viewing Stored Data
33
Transferring Stored Data to the Computer (Cybercomm) through Irda
34
Transferring Stored Data to a PC Not Equipped with Infrared Receiver
35
Transferring Stored Data to a PC Using an USB/ Irda Dongle
36
Technical Specifications
37
Accessories
41
Warranty & Return Policy
42
Warranty
42
Return of Goods
42
Guidelines for Returning Unit for Repair
43
Temperature
44
Temperature Setup
46
Temperature Calibration
46
About Temperature Calibration
46
Temperature Calibration for ATC Mode
47
Temperature Calibration for MTC Mode
48
Temperature Measurement
48
Ph Setup
52
Ph Calibration
53
About Ph Calibration
53
Ph Buffer Group for Calibration and Auto-Recognition
54
Ph Calibration Points
54
Ph Calibration with a Standard Buffer
54
To Start Ph Calibration
54
Ph Calibration with a User-Defined Buffer
56
Calibration Report
57
To View Calibration Report
57
Average Slope Indicator of Ph Probe
58
Ph Measurement Mode
58
Resolution of Ph Reading
58
Indicators in Ph Measurement Screen
59
MV Setup Mode
62
MV Calibration Mode
62
MV Calibration with a Standard ORP Calibration Solution
62
Calibration Report
63
To View Calibration Report
63
MV Measurement Mode
63
Indicators in MV Measurement Mode
63
Ion
66
Ion Setup
68
Ion Calibration Mode
68
About Ion Calibration
68
Calibration Report
70
To View Calibration Report
70
Ion Measurement Mode
71
Changing Unit of Measurement
71
Indicators in Ion Measurement Mode
71
Conductivity
72
Conductivity Setup
74
Conductivity Calibration Mode
76
Conductivity Calibration Points
76
Cell Constant
76
Normalization Temperature ( ° C)
76
Linear Temperature Coefficient
76
Pure Water Coefficient
77
To Begin Calibration
77
Manual Calibration
78
Automatic Calibration (for Conductivity Calibration)
78
Calibration Report
80
To View Calibration Report
80
Conductivity Measurement Mode
80
Indicators in Conductivity Measurement Screen
80
Tds
83
TDS Setup
85
TDS Calibration Mode
87
TDS Calibration Report
88
To View Calibration Report
88
TDS Measurement Mode
89
Indicators in TDS Measurement Mode
89
About TDS
90
Calculating TDS Conversion Factor
90
Calculating Temperature Coefficients
90
Salinity
91
Salinity Setup
93
Salinity Calibration Mode
94
Salinity Calibration Report
96
To View Salinity Report
96
Salinity Measurement Mode
97
Indicators in Salinity Measurement Mode
97
Resistivity
99
Resistivity Setup
101
Resistivity Calibration Mode
103
Resistivity Calibration Report
104
To View Calibration Report
104
Resistivity Measurement Mode
105
Indicators in Resistivity Measurement Mode
105
Dissolved Oxygen
107
PART a - % Saturation Mode
109
O2 % - DO Saturation Setup
109
DO Calibration in % Saturation Mode (with ATC)
111
About DO(%) and DO (Mg/L) Calibration
111
To Calibrate 100% Saturation
111
To Calibrate 0% Saturation
113
DO Calibration Report
114
To View Calibration Report
114
Saturation Offset Adjustment
115
Set Barometer Pressure Range and Barometric Pressure Units
115
Pressure Compensation
115
Percentage Saturation (%) Measurement Mode
115
Indicators in Percentage Saturation Measurement Mode
115
PART B - Concentration (Mg/L) (Ppm) Mode
116
O2 Mg/L (Ppm) - DO Concentration Setup
116
DO Calibration in Mg/L Mode or Ppm Concentration Mode
119
Concentration Calibration Report
120
To View Calibration Report
120
Set Salinity
121
Auto Salinity Compensation
121
Concentration in Measurement Mode
121
Indicators in Concentration Measurement Screen
121
Dissolved Oxygen Probe
122
Dissolved Oxygen Principle
122
Probe Care
123
Membrane Housing Replacement
123
Membrane/O-Ring Replacement (Optional Procedure)
124
Electrolyte Solution
125
Advertisement
EUTECH INSTRUMENTS DO 600 Instruction Manual (64 pages)
Waterproof Handheld Dissolved Oxygen Meter
Brand:
EUTECH INSTRUMENTS
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
5
Getting Started
7
About the Meter
7
Display & Keypad
8
Display Overview
8
Key Functions
9
Inserting Batteries
10
Inserting Batteries for the First Time
10
Changing Batteries Subsequently
11
Connecting DC Power Adapter
11
Attaching Safety Belt
12
Connecting Peripherals
13
DO Probe
13
Connecting the DO Probe to the Meter
13
Protective Rubber Boot
14
Cybercomm 600 Data Acquisition Software
15
About Cybercomm 600 das Application
15
Installing Cybercomm 600
15
Starting Cybercomm 600 for the First Time
15
Connecting to the Meter
17
Measurement Mode
20
About Measurement Mode
20
Accessing Functions
20
Taking Measurement
22
Prepare the Meter for Measurement
22
Taking a Reading
22
Stable Reading Indicator
22
Holding a Reading
22
Automatic Temperature Compensation (ATC)
23
Manual Temperature Compensation (MTC)
23
DO Alarm
23
Calibration Due (CAL-DUE) Indicator
23
Set Salinity
23
Saturation Offset Adjustment
24
Set Barometer Pressure Range and Barometric Pressure Units
24
Pressure Compensation
24
Concentration (Mg/L) (Ppm) Measurement Mode
25
Indicators in Concentration Measurement Screen
25
Percentage Saturation (%) Measurement Mode
26
Indicators in Percentage Saturation Measurement Mode
26
Transfer Measured Data to Computer (Cybercomm)
27
Sending a Single Reading
27
Sending Readings Continuously
28
Saving Data
29
Working with Memory Functions
30
Logging Data Automatically in Meter's Memory
30
Storing Currently Displayed Reading in the Memory (in Irda and LED Print Mode)
30
Viewing Stored Data
30
Transferring Stored Data to Computer (Cybercomm) through Irda
31
Calibration Mode
33
Important Information on Meter Calibration
33
Prepare the Meter for Calibration
33
Accessing Calibration Mode
33
Accessing Calibration Mode When Password Protection Enabled
34
About Temperature Calibration
35
Temperature Calibration for ATC Mode
35
Temperature Calibration for MTC Mode
36
DO Calibration in % Saturation Mode (with ATC)
37
To Calibrate 100% Saturation
37
To Calibrate 0% Saturation
39
DO Calibration Report
39
DO Calibration in Mg/L or Ppm Concentration Mode
41
Concentration Calibration Report
42
Setup Mode
43
About Setup Mode
43
Accessing Setup Mode (no Password Protection Enabled)
43
Accessing Setup Mode When Password Protection Enabled
45
Modifying Setup Parameters
46
System Setup
47
System Settings
47
System Settings
48
System Settings
49
System Settings
50
System Settings
51
System Settings
52
O 2 % - DO Saturation Setup
53
Do (%)
53
Do (%)
54
O 2 Mg/L (Ppm) - DO Concentration Setup
55
DO (Mg/L)
55
DO (Mg/L)
56
Temperature Setup
57
Temperature Setting Page
57
Technical Specifications
58
Accessories
59
Replacement Accessories
59
Optional Accessories
59
General Information
61
Warranty
61
Return of Goods
61
Guidelines for Returning Unit for Repair
61
Advertisement
Related Products
EUTECH INSTRUMENTS DO 6PLUS DISSOLVED OXYGEN TEMP
EUTECH INSTRUMENTS DO 6 - REV 2
EUTECH INSTRUMENTS ECOSCAN DO 6 DO METER
EUTECH INSTRUMENTS DO 6
EUTECH INSTRUMENTS CYBERSCAN DO 100 DISSOLVED OXYGEN METER
EUTECH INSTRUMENTS CYBERSCAN DO 5000 DO METER
EUTECH INSTRUMENTS DO 2700
EUTECH INSTRUMENTS DO 700
EUTECH INSTRUMENTS OAKTON DO 110
EUTECH INSTRUMENTS CyberScan DO 310
EUTECH INSTRUMENTS Categories
Measuring Instruments
Transmitter
Accessories
Test Equipment
Controller
More EUTECH INSTRUMENTS Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL