Sign In
Upload
Manuals
Brands
EUCHNER Manuals
Safety Equipment
CTS-C1-BR-CC-FLX-AP-VAB-169612
EUCHNER CTS-C1-BR-CC-FLX-AP-VAB-169612 Manuals
Manuals and User Guides for EUCHNER CTS-C1-BR-CC-FLX-AP-VAB-169612. We have
2
EUCHNER CTS-C1-BR-CC-FLX-AP-VAB-169612 manuals available for free PDF download: Operating Instructions Manual
EUCHNER CTS-C1-BR-CC-FLX-AP-VAB-169612 Operating Instructions Manual (48 pages)
Transponder-Coded Safety Switch with Guard Locking, High/Low Coding Level
Brand:
EUCHNER
| Category:
Safety Equipment
| Size: 7 MB
Table of Contents
Table of Contents
2
About this Document
4
Scope
4
Target Group
4
Key to Symbols
4
Supplementary Documents
4
Correct Use
5
Description of the Safety Function
7
With Active Guard Lock Monitoring
7
With Inactive Guard Lock Monitoring
8
Exclusion of Liability and Warranty
9
General Safety Precautions
9
Function
10
Guard Lock Monitoring
10
Monitoring Outputs/Status Bits
10
Guard Locking Signal OL
10
Door Position 1 Signal OD
10
Door Position 2 Signal OT
11
Diagnostic Signal OI
11
Escape Release Signal OER
11
Status Signal OM
11
Locking Element Signal OLS
11
Communication Connection C
11
Guard Locking
11
Switching States
12
Manual Release
13
Auxiliary Release
13
Actuating Auxiliary Release
13
Escape Release
14
Actuating Escape Release
14
Mounting
15
Electrical Connection
18
Notes on
19
Safety in Case of Faults
19
Fuse Protection for Power Supply
19
Requirements for Connecting Cables
20
Connector Assignment/Terminal Assignment of Safety Switch CTS
20
Connector Assignment of Safety Switch CTS
21
Notes on Operation with Safe Control Systems
22
Connection Without and with IO-Link Communication
22
Connection Without IO-Link Communication
22
Connection with IO-Link Communication
22
Connection of a Single CTS-C1-BP/BR-FLX (Separate Operation)
23
Connection of Several Devices in a Chain (Series Connection)
24
Series Connection with Wiring in the Control Cabinet
24
Series Connection with Y-Distributors
24
Maximum Cable Lengths for BR Switch Chains with CTS
25
With Plug Connectors 2 X M12, CTS
25
Maximum Cable Lengths for BR Switch Chains with CTS-C1-BR
26
With Plug Connector M12, 8-Pin
26
Connector Assignment of Y-Distributor for Series Connection Without IO-Link Communication
27
Connector Assignment of Y-Distributor for Series Connection with IO-Link Communication
29
Using Communication Data
30
Connection to a BR/IO-Link Gateway GWY-CB
30
Connection to a Safety Relay ESM-CB
30
Overview of the Communication Data
31
Cyclical Data (Process Data)
31
Acyclical Data (Device Data and Events)
31
Setup
33
Configuring Device and Teaching-In Actuator for the First Time
33
Teaching-In New Actuator (Only for Evaluation of the Actuator with a High Coding Level)
34
Functional Check
35
Mechanical Function Test
35
Electrical Function Test
35
Factory Reset
36
Status and Error Messages
36
LED Displays
36
Status Messages
37
Error Messages
38
Acknowledging Error Messages
40
Technical Data
41
Technical Data for Safety Switch CTS-C1-BP/BR-FLX
41
Typical System Times
43
Radio Frequency Approvals
44
Dimension Drawing for Safety Switch CTS
45
Technical Data for Actuator A-FLX-D-0
46
Dimension Drawing for Actuator A-FLX-D-0
46
Ordering Information and Accessories
47
Inspection and Service
47
Service
47
Declaration of Conformity
47
Advertisement
EUCHNER CTS-C1-BR-CC-FLX-AP-VAB-169612 Operating Instructions Manual (48 pages)
Transponder-Coded Safety Switch with Guard Locking
Brand:
EUCHNER
| Category:
Safety Equipment
| Size: 7 MB
Table of Contents
Table of Contents
2
About this Document
4
Scope
4
Target Group
4
Key to Symbols
4
Supplementary Documents
4
Correct Use
5
Description of the Safety Function
7
With Active Guard Lock Monitoring
7
With Inactive Guard Lock Monitoring
8
Exclusion of Liability and Warranty
9
General Safety Precautions
9
Function
10
Guard Lock Monitoring
10
Monitoring Outputs/Status Bits
10
Guard Locking Signal OL
10
Door Position 1 Signal OD
10
Door Position 2 Signal OT
11
Diagnostic Signal OI
11
Escape Release Signal OER
11
Status Signal OM
11
Locking Element Signal OLS
11
Communication Connection C
11
Guard Locking
11
Switching States
12
Manual Release
13
Auxiliary Release
13
Actuating Auxiliary Release
13
Escape Release
14
Actuating Escape Release
14
Mounting
15
Electrical Connection
18
Notes about
19
Safety in Case of Faults
19
Fuse Protection for Power Supply
19
Requirements for Connecting Cables
20
Connector Assignment/Terminal Assignment of Safety Switch CTS
21
Connector Assignment of Safety Switch CTS
21
Notes on Operation with Safe Control Systems
22
Connection Without and with IO-Link Communication
22
Connection Without IO-Link Communication
22
Connection with IO-Link Communication
22
Connection of a Single CTS-C1-BP/BR-FLX (Separate Operation)
23
Connection of Several Devices in a Chain (Series Connection)
24
Series Connection with Wiring in the Control Cabinet
24
Series Connection with Y-Distributors
24
Maximum Cable Lengths with BR Switch Chains
25
Determining Cable Lengths Using the Example Table
25
Connector Assignment of Y-Distributor for Series Connection Without IO-Link Communication
26
Connector Assignment of Y-Distributor for Series Connection with IO-Link Communication
28
Using Communication Data
29
Connection to a BR/IO-Link Gateway GWY-CB
29
Connection to a Safety Relay ESM-CB
29
Overview of the Communication Data
30
Cyclical Data (Process Data)
30
Acyclical Data (Device Data and Events)
30
Setup
32
Configuring Device and Teaching-In Actuator for the First Time
32
Teaching-In New Actuator (Only for Evaluation of the Actuator with a High Coding Level)
33
Functional Check
34
Mechanical Function Test
34
Electrical Function Test
34
Factory Reset
35
Status and Error Messages
35
LED Displays
35
Status Messages
36
Error Messages
37
Acknowledging Error Messages
39
Technical Data
40
Technical Data for Safety Switch CTS-C1-BP/BR-FLX
40
Typical System Times
42
Radio Frequency Approvals
43
Dimension Drawing for Safety Switch CTS
44
Technical Data for Actuator A-FLX-D-0
45
Dimension Drawing for Actuatora-FLX-D-0
45
Ordering Information and Accessories
46
Inspection and Service
46
Service
46
Declaration of Conformity
46
Advertisement
Related Products
EUCHNER CTS-C1-BR-CC-FLX-AP-V05-169053
EUCHNER CTS-C1-BR-CC-FLX-AP-UAB-173374
EUCHNER CTS-C1-BR-CC-FLX-AP-VSA-174014
EUCHNER CTS-C1-BP-FLX
EUCHNER CTS-C1-BR-FLX
EUCHNER CTS-C1-BP-CC-FLX-AP-VSA-167917
EUCHNER CTS-C1-BP-CC-FLX-AP-VSA-171593
EUCHNER CTS-C1-BP-CC-FLX-AP-VSA-169052
EUCHNER CTS-C1-BP-CC-FLX-AP-USA-172870
EUCHNER CTS-C2-BP-CC-FLX-AP-USA-174157
EUCHNER Categories
Switch
Safety Equipment
Control Unit
Relays
Adapter
More EUCHNER Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL