Sign In
Upload
Manuals
Brands
Et system Manuals
Power Supply
N31200 Series
Et system N31200 Series Manuals
Manuals and User Guides for Et system N31200 Series. We have
1
Et system N31200 Series manual available for free PDF download: Programming Manual
Et system N31200 Series Programming Manual (86 pages)
CANopen Protocol
Brand:
Et system
| Category:
Power Supply
| Size: 1 MB
Table of Contents
Table of Contents
2
Contents
8
Preface
8
Safety Instructions
9
Safety Notes
9
Safety Symbols
9
Canopen Overview
10
Communication Method
11
Can Format
11
Commands
13
Status Reading
13
Output Setting
14
Source Current Setting
14
Voltage Setting
14
Load Current Setting
15
Source Power Setting
15
Load Power Setting
16
Readback
16
Readback Voltage
16
Readback Charging Milliampere-Hour
17
Readback Current
17
Readback Power
17
Readback Temperature
18
Reading Maximum Voltage Range
18
Reading Range
18
Format
19
Main Index Sub Index Read/Write Data Type Byte Size
19
Over Voltage Protection
19
Protection Parameters
19
Reading Maximum Current Range
19
Reading Maximum Power Range
19
Setting Command: 23 01 20 00 88 13 00
19
0X2001 0X00 WR Int
20
Over Current Protection
20
Over Power Protection
20
Over Voltage Protection Delay Time
21
Under Current Protection
21
Under Voltage Protection
21
Over Current Protection Delay Time
22
Over Power Protection Delay Time
22
Under Current Protection Ready Time
23
Under Voltage Protection Delay Time
23
Under Voltage Protection Ready Time
23
ON-OFF Control
24
Power Supply Protection
24
Under Current Protection Delay Time
24
Current Rise Slew
25
Priority Mode
25
Voltage Rise Slew
25
Delay Time on
26
Operation Mode
26
Delay Time off
27
Timing Shutdown
27
Digital Input Signal 1
28
External Programming
28
Timer Shutdown
28
Trigger Wave
28
0X2001 0X01 WR Int
29
0X2001 0X02 WR Int
29
Control Mode
29
Digital Input Signal 2
29
Format
29
Index. 00 Indicates Sub Index
29
Main Index Sub Index Read/Write Data Type Byte Size
29
Return of Setting Command: 60 01 20
29
The Red Portion of the Data 60 Indicates Successful Writing. 01 20 Indicates Main
29
Control Mode
30
Digital Input Signal 3
30
Index. 02 Indicates Sub Index
30
Control Mode
31
Digital Output Signal 1
31
Analogue Reference Voltage
32
Digital Output Signal 2
32
Digital Output Signal 3
32
Analogue Programming Channel 1
33
Analogue Programming Channel 2
33
Analogue Monitor Channel 1
34
Analogue Monitor Channel 2
34
Cycle Times
35
SEQ Edit
35
SEQ File no
35
Total Steps
35
Link to File
36
Step no
36
Load Current Setting
37
Source Current Setting
37
Voltage Setting
37
Dwell Time
38
Dwell Time Unit
38
Source Power Setting
38
Current Slew Setting
39
Load Power Setting
39
Voltage Slew Setting
39
Default Value: 1
40
Present Cycle Times
40
Present Step no
40
Return of Reading Command: 43 01 20
40
SEQ File
40
SEQ Test
40
Current Setting
41
Discharge Mode
41
Dwell Time for Present Step
41
Dwell Time Unit for Present Step
41
Capacity Setting
42
Cutoff Voltage Setting
42
Power Setting
42
Charge Mode
43
Current Setting
43
Cutoff Time Setting
43
Voltage Setting
43
Capacity Setting
44
Cutoff Current Setting
44
Cutoff Voltage Setting
44
Cutoff Time Setting
45
Internal Resistance Simulation
45
Max. Current Setting
45
Voltage Setting
45
Constant Resistance
46
Internal Resistance Setting
46
Max. Power Setting
46
Resistance Setting
46
Car Test
47
Max. Current Setting
47
Max. Power Setting
47
Trigger Car Waveform
47
Level1 Search Term
48
Level2 Search Term
48
Leve3 Search Term
49
Leve4 Search Term
50
Waveform Setting I
51
Waveform Setting II
52
Waveform Setting III
53
Source Current Setting
54
Step Test
54
Voltage Setting
54
Load Current Setting
55
Load Power Setting
55
Source Power Setting
55
Cycle Times
56
Mode Selection
56
Trigger Mode
56
End
57
Start
57
File no
58
Increment
58
Increment Time
58
Wave Edit
58
Cycle Times
59
File Length
59
Link to File
59
Mode Selection
60
Step no
60
Amplitude
61
Dwell Time
61
Voltage Setting
61
Wave Run
61
Load Current Setting
62
Source Current Setting
62
Source Power Setting
62
File no
63
Load Power Setting
63
Cycle Times
64
Dwell Time
64
Output Mode
64
Step no
64
Anywave Test
65
Source Current Setting
65
Voltage Setting
65
Load Current Setting
66
Load Power Setting
66
Source Power Setting
66
Mode Selection
67
Wave File
67
Output Amplitude
68
Output Bias
68
Wave Selection
68
Frequency Setting
69
Output Phase
69
Percentage
69
Advanced Edit
70
File Length
70
File no
70
Cycle Times
71
Link to File
71
Mode Selection
71
Output Amplitude
72
Step no
72
Wave File
72
Frequency Setting
73
Output Bias
73
Output Phase
73
Percentage
74
Set-Up Time
74
Advanced Operation
75
Dwell Time
75
Source Current Setting
75
Voltage Setting
75
Load Current Setting
76
Source Power Setting
76
File no
77
Load Power Setting
77
Step no
77
Cycle Times
78
Dwell Time
78
Output Mode
78
CANOPEN Baud Rate
79
Canopen ID
79
Device ID
79
System Setting
79
Power-Off Memory
80
RS232/RS485 Baud Rate Setting
80
Factory Reset
81
IP Setting
81
Beeper
82
Language
82
Example
83
Gateway
83
Normal Mode
83
Subnet Mask
83
SEQ Mode
84
Simulated Resistance
85
Factory Reset
86
Advertisement
Advertisement
Related Products
Et system N35200 Series
Et system N35212-500-80
Et system N35218-500-120
Et system N35236-500-240
Et system N35100 Series
Et system N35514-500-65
Et system N35542-500-195
Et system N35522-1500-60
Et system N35532-1500-60
Et system N35500 Series
Et system Categories
Power Supply
Portable Generator
Test Equipment
Garage Door Opener
Security Sensors
More Et system Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL