Sign In
Upload
Manuals
Brands
Erbe Manuals
Measuring Instruments
ERBECRYO 2
User Manuals: Erbe ERBECRYO 2 Cryosurgical Unit
Manuals and User Guides for Erbe ERBECRYO 2 Cryosurgical Unit. We have
4
Erbe ERBECRYO 2 Cryosurgical Unit manuals available for free PDF download: Manual, User Manual, Service Manual, Quick Manual
Erbe ERBECRYO 2 User Manual (80 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 3 MB
Table of Contents
Table of Contents
5
1 General Instructions for Use
9
Intended Use / Indications for Use
9
Compatibility
9
Contraindications
9
Intended Patient Population
9
Environment
9
Qualification of User
9
Performance Characteristics
9
2 Safety Instructions
11
Safety Notations
11
Meaning of the Note
11
Who Must Read this User Manual
11
Compliance with Safety Information
12
Structure of Safety Instructions
12
Operating Errors and Incorrect Installation by Persons Without Training
12
Risks Due to the Environment
13
Electric Shock
14
Caused by Other Equipment
15
Risks Due to Operating Errors
16
Defective Unit
16
Risks Due to Instruments
17
Risk of Infection
18
Fire / Explosion
18
Risks Due to Unsuitable Accessories
19
Risks Due to the Compressed Gas Bottle
19
• Safety Instructions Warning
20
Risks Due to Gas
20
Notes
21
3 Safe Handling of Carbon Dioxide and the Gas Bottle
23
Safety Instructions Provided by the Gas Supplier, Training
23
Properties of Carbon Dioxide
23
Transport and Storage of the Gas Bottle, Working with the Gas Bottle
24
4 Description of the Controls
27
Controls on the Front Panel
27
Controls on the Back
28
5 Installation
29
Ambient Conditions
29
Do Not Place the CO 2 Bottle Close to a Heat Source. Heaters or Air
30
Conditioners Are Examples of Heat Sources. Do Not Actively Heat
30
Bottle, E.g. Using a Fan Heater. Do Not Expose the CO 2 Bot
30
Tle to Direct Sunlight
30
Installing the Unit on an Erbe Cart
31
Connecting Tubes and the Footswitch
31
Dangerous CO 2 Concentration in Room
31
A High Concentration of CO 2 in the Air Can Cause Suffocation. CO
31
Heavier than Air. if Discharge Is Not Controlled, Dangerous Accumula
31
Tions Can Develop Close to the Ground
31
Observe the National Regulations Regarding Concentrations of CO
31
Permitted in the Workplace
31
Connecting Gas Bottle to Gas Bottle Adapters
33
Operate and Store the CO
33
CO Bottle with Dip Tube, Horizontal CO Bottle
33
Liquid CO
33
The Unit May be Damaged
33
Connecting Gas Bottle to Switch Valve 20402-052
34
Changing Gas Bottle (When Using a Gas Bottle Adapter)
35
Changing Gas Bottles (When Using a Switch Valve)
36
Switching between Two Gas Bottles with the Switch Valve
36
Electrical Connection
37
6 Working with ERBECRYO 2
39
Checking the Unit and Accessories
39
Putting the Gas Bottle into Operation
39
Switching On, Self-Test
39
Instrument Connection, Main Screen
40
Setting the Effect, Setting the Timer
41
Freezing, Thawing
44
Saving a Program
45
Selecting a Program
45
Overwriting a Program
48
Deleting a Program
49
Calling up Information on the Instrument
50
Checking Input Pressure
51
Calling up Setup
52
L1 R1
52
L2 R2
52
L3 R3
52
Fig
52
Bleeding the Cryosystem off after Use
53
Disassembling the Unit
54
7 Cleaning and Disinfection
55
Safety Instructions
55
Selecting a Suitable Cleaning and Disinfection Agent
56
Supplies
56
Cleaning
56
Disinfection
57
Validated Procedure for Cleaning and Disinfection
57
8 Status Messages, Error Messages
59
Error Messages on a Blue Screen
59
Status Messages
59
Error Messages
60
9 Technical Data
63
10 Notes on Electromagnetic Compatibility (EMC)
65
11 Maintenance, Customer Service, Warranty, Disposal
71
Maintenance
71
Customer Service
71
Warranty
71
Disposal
72
12 Accessories
73
Introduction
73
ERBECRYO 2 Example Accessories
74
Compatible Instruments
75
Compatible Footswitches
75
Compatible Gas Tube, Waste Gas Tube
75
Compatible Gas Bottle Adapter
75
Compatible Power Cords
75
13 Symbols
77
Index
79
Advertisement
Erbe ERBECRYO 2 Manual (113 pages)
one pedal footswitch
Brand:
Erbe
| Category:
Mobility Aid
| Size: 6 MB
Table of Contents
Bestimmungsgemäßer Gebrauch
4
Reinigen und Desinfizieren
6
Intended Use
10
Normal Use
10
Safety Instructions
10
How to Use
11
Cleaning and Disinfection
12
Notice D'utilisation
15
Utilisation Conforme
16
Consignes de Sécurité
16
Consignes D'utilisation
17
Nettoyage Et Désinfection
18
Uso Previsto
22
Indicaciones de Seguridad
22
Limpieza y Desinfección
24
Impiego Previsto
28
Indicazioni DI Sicurezza
28
Indicazioni Per L'utilizzo
29
Pulizia E Disinfezione
30
Utilização Prevista
34
Indicações de Segurança
34
Instruções de Utilização
35
Σκοπός Χρήσης
40
Αρμόζουσα Χρήση
40
Υποδείξεις Ασφαλείας
40
Καθαρισμός Και Απολύμανση
43
Beoogd Gebruik
46
Gebruik Conform de Voorschriften
46
Reiniging en Desinfectie
48
Formålsbestemt Anvendelse
52
Rengøring Og Desinfektion
54
Avsedd Användning
58
Rengöring Och Desinfektion
60
Määräystenmukainen Käyttö
64
Puhdistus Ja Desinfiointi
66
Użytkowanie Zgodne Z Przeznaczeniem
70
Wskazówki Dotyczące Bezpieczeństwa
70
Zamýšlené Použití
76
Použití K Určenému Účelu
76
Bezpečnostní Pokyny
76
Rendeltetésszerű Használat
82
Biztonsági Utasítások
82
Használati Útmutató
83
Использование По Назначению
88
Указания По Безопасности
88
Указания По Применению
89
Очистка И Дезинфекция
90
KullanıM Amacı
94
Amaca Uygun KullanıM
94
Güvenlik Notları
94
KullanıM Bilgileri
95
Elden Çıkarma
97
Erbe ERBECRYO 2 Service Manual (46 pages)
Brand:
Erbe
| Category:
Medical Equipment
| Size: 0 MB
Table of Contents
Table of Contents
5
Safety Information
7
Classification of the Safety Information
7
Knowledge of the User Manual
7
Protection from the Risk of Electric Shock
7
Handling Compressed Gas Cylinders
8
Electrostatically Sensitive Components
8
Liability and Warranty
8
Controls
9
Controls at the Front
9
Controls at the Rear
10
Technical Data
11
Setup and Service Settings
13
General Information
13
Overview of Setup Settings
13
Overview of Service Settings
14
Call up Setup and Service Settings
15
Change Setup and Service Settings
16
Remedying Malfunctions
17
Safety Information
17
Error Messages
17
Maintenance and Servicing
29
Who Is Allowed to Perform Servicing and Maintenance Work
29
What Is a Technical Safety Check
29
How Often Does a Technical Safety Check Have to be Performed
29
Technical Safety Check - Step by Step
30
Safety Information
30
Testing and Measuring Equipment
31
User Manual and Visual Inspections
32
Tests to be Conducted in Accordance with the National Specifications and Regulations
32
Performance Tests
32
Footswitch Activation
33
Instrument Recognition
34
Seal Tests
35
Obstruction Tests
38
Flow Measurement
40
Replacing Wear Parts
41
Wear Parts - Overview
41
Safety Information
41
Changing the Inlet Filter (up to Serial Number 11492198)
42
Changing the Inlet Filter (as from Serial Number 11492199)
43
Cleaning the Prefilter for Flow Sensor Assembly
45
Advertisement
Erbe ERBECRYO 2 Quick Manual (2 pages)
Brand:
Erbe
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Opening the Gas Bottle
1
Switch on the Device
1
Connecting the Instrument
1
Checking the Reusability of the Instrument
1
Checking the Function and Seal of the Instrument
1
Freezing
1
Thawing
1
Closing the Gas Bottle after Use
2
Select Program
2
Changing the Effect
2
Changing the Timer Setting
2
Advertisement
Related Products
Erbe 20191-152
Erbe 20416-032
Erbe 20416-037
Erbe 20186-007
Erbe 20187-003
Erbe 20189-015
Erbe 20188-007
Erbe 20189-027
Erbe 20321-011
Erbe 20321-001
Erbe Categories
Medical Equipment
Cables and connectors
Adapter
Measuring Instruments
Industrial Electrical
More Erbe Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL