Sign In
Upload
Manuals
Brands
Enotec Manuals
Measuring Instruments
OXITEC 5000 DustEx
Enotec OXITEC 5000 DustEx Manuals
Manuals and User Guides for Enotec OXITEC 5000 DustEx. We have
1
Enotec OXITEC 5000 DustEx manual available for free PDF download: Installation And Operation Manual
Enotec OXITEC 5000 DustEx Installation And Operation Manual (66 pages)
O2 / COe Analyzer System ATEX
Brand:
Enotec
| Category:
Measuring Instruments
| Size: 5 MB
Table of Contents
Table of Contents
3
System Description
5
Distinction between COMTEC / OXITEC Dustex
5
System Overview
5
Measuring Principle
6
Intended Use
6
Safety Hazards
6
Disruption of the Process
6
Storage Instructions
7
Name Plates
8
Installation
9
Installation Requirements for Electronic Unit
9
Installation Requirements for Probe Cable
10
Access to the Terminals
11
Fitting of Ferrite Sleeves
11
Wiring Diagram of the Electronic Unit
13
Electrical Wiring Diagram - OXITEC Dustex
14
Electrical Wiring Diagram - COMTEC Dustex
15
Installation of the Probe
16
Mounting of the Counter Flange at the Duct
17
Adjusting the V-Shield
17
Mounting of the Probe
18
Electrical Connections of the Probe
18
Requirements for Pneumatic Cable FEP-0002
19
Preparation of the Pneumatic Cable
20
Pneumatic Connections of the Probe
20
Pneumatic Connections of the Electronic Units
21
Initial Operation
22
Checklist before Commissioning the System
22
System Power up
22
Display - Probe Heating Phase
23
Display - Measuring Mode
23
Keypad and Display
23
Status Leds
24
Softkey Symbols
24
System Code
24
Menu Overview and Explanations
25
Menu Overview - SYS-MENU
25
Menu Explanations - SYS-MENU
29
O 2 Measuring Ranges (Scaling)
29
Limit Alarm Settings
29
Sensor Calibration Values
29
Measuring Value Averaging for
29
Ma Output on System Errors
29
Coe Measuring Ranges (Scaling)
30
Coe Sensor Calibration Values
30
Time Per Test Gas Apply
30
Delay Time to Process
30
Pre-Purge Time
30
Automatic Calibration (ACAL)
31
Enotec Remote
32
Measuring Units
32
Language
32
Change System Code
32
Load Factory Settings
33
Set Coe Measurement to Off/On
33
Service
33
System Checks
34
Cal Menu
35
Calibration Menu - Display Overview
35
1-Point Calibration
36
And/Or Coe) (Manual)
36
Service and Maintenance
37
Exchange Fuses
37
Flow Rates for Test Air and Reference Air
38
Adjusting Flow Rate (SME 53 with Integrated Pneumatics)
38
Position of the Adjustment Valves
39
Adjusting Flow Rate (SME-54)
39
Replacing the Filter Head
40
Replacing the Probe
40
Exchange of Probe Inner Parts
41
Replacing the O
42
Sensor
42
Replacing the Coe Sensor (COMTEC)
43
Seal the Coe Sensor Guide Tube
44
Relay Outputs / Functions and Correlations
45
Digital Inputs
46
Stability Criteria for Calibration
46
Reaction Time of the Ma Output
46
Extension Modules
46
Maintenance Intervals
46
Status Messages
47
Error Messages
47
Alarm Messages
49
Service Messages
49
Heater Control Unit
50
Troubleshooting
51
Technical Data
53
Probe
54
Requirements for the Gas Supply
55
Dimension Drawings
56
Dimensions of the Electronic Units
56
Probe Dimensions
57
Counter Flange Dimensions
58
Probe Components
59
Gas Plan
60
Spare Parts
61
Mounting Plates of the Electronic Unit
61
Display Board
62
Warranty
63
Declaration of Conformity
64
Index
66
Advertisement
Advertisement
Related Products
Enotec OXITEC 5000+
Enotec OXITEC ECONOMY
Enotec COMTEC 6000 ATEX GasEx
Enotec COMTEC 6000 DustEx
Enotec ENSITU 7000
Enotec SILOTEC 8000
Enotec Categories
Measuring Instruments
Analytical Instruments
More Enotec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL