Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Controller
Liquiline CM444
Endress+Hauser Liquiline CM444 Manuals
Manuals and User Guides for Endress+Hauser Liquiline CM444. We have
7
Endress+Hauser Liquiline CM444 manuals available for free PDF download: Operating Instructions Manual, Brief Operating Instructions
Endress+Hauser Liquiline CM444 Operating Instructions Manual (178 pages)
Universal four-wire multichannel controller Field device
Brand:
Endress+Hauser
| Category:
Controller
| Size: 10 MB
Table of Contents
Table of Contents
3
1 Document Information
5
Warnings
5
Symbols Used
5
Documentation
6
2 Basic Safety Instructions
7
Requirements for Personnel
7
Designated Use
7
Occupational Safety
8
Operational Safety
8
Product Safety
8
3 Device Description
9
Housing Closed
9
Housing Open
9
Device Architecture
10
4 Incoming Acceptance and Product Identification
12
Incoming Acceptance
12
Product Identification
12
Scope of Delivery
13
Certificates and Approvals
13
5 Installation
14
Installation Conditions
14
Mounting the Measuring Device
16
Post-Installation Check
19
6 Electrical Connection
20
Connection Conditions
20
Connecting the Measuring Device
23
Connecting the Sensors
30
Connecting Additional Inputs, Outputs or
32
Relays
34
Connecting Digital Communication
36
Hardware Settings
40
Guaranteeing the Degree of Protection
40
Post-Connection Check
41
7 System Integration
42
Web Server
42
Service Interface
44
Fieldbuses
45
8 Operation Options
46
Overview
46
Access to the Operating Menu Via the Local Display
47
Configuration Options
48
9 Commissioning
52
Function Check
52
Switching on the Unit
52
Basic Setup
54
10 Operation
55
Display
55
General Settings
58
Current Inputs
72
Outputs
73
Binary Inputs and Outputs
82
Additional Functions
90
11 Diagnostics and Troubleshooting
119
General Troubleshooting
119
Diagnostic Information on the Local
120
Display
120
Diagnostic Information Via Web
120
Browser
120
Diagnostic Information Via Fieldbus
120
Adjusting Diagnostic Information
121
Overview of Diagnostic Information
124
Pending Diagnostic Messages
127
Diagnostics List
127
Event Logbook
127
11.10 Simulation
131
11.11 Reset Measuring Instrument
132
11.12 Device Information
133
11.13 Firmware History
136
12 Maintenance
138
Calibration
138
Cleaning
139
13 Repair
141
Spare Parts
141
Return
144
Disposal
144
14 Accessories
145
Weather Protection Cover
145
Post Mounting Kit
145
Measuring Cable
145
Sensors
146
Additional Functionality
150
Software
152
Other Accessories
153
15 Technical Data
155
Input
155
Digital Inputs, Passive
156
Current Input, Passive
156
Output
157
Digital Outputs, Passive
159
Current Output, Active
160
Relay Outputs
161
Protocol-Specific Data
162
Power Supply
165
15.10 Performance Characteristics
167
15.11 Environment
168
15.12 Mechanical Construction
170
16 Installation and Operation in Hazardous Environment Class I
170
DIV. 2
170
Environment/Properties
170
Control Drawing
171
Index
172
Advertisement
Endress+Hauser Liquiline CM444 Operating Instructions Manual (170 pages)
Universal four-wire multichannel controller Field device
Brand:
Endress+Hauser
| Category:
Controller
| Size: 9 MB
Table of Contents
Table of Contents
3
About this Document
5
Warnings
5
Symbols
5
Symbols on the Device
5
Documentation
6
Basic Safety Instructions
7
Requirements for the Personnel
7
Intended Use
7
Workplace Safety
8
Operational Safety
8
Product Safety
8
Device Description
9
Housing Closed
9
Standard Device
9
Open Device with Sensor Communication Module Type 2DS Ex-I
10
Slot and Port Assignment
11
Terminal Diagram
12
Incoming Acceptance and Product
13
Identification
13
Incoming Acceptance
13
Product Identification
13
Scope of Delivery
14
Certificates and Approvals
14
Mounting
16
Mounting Requirements
16
Mounting the Measuring Device
17
Post-Mounting Check
20
Electrical Connection
21
Connection Conditions
21
Connecting the Measuring Device
21
Connecting the Sensors
28
Connecting Additional Inputs, Outputs or Relays
31
Connecting PROFIBUS DP or Modbus RS 485
35
Hardware Settings
38
Ensuring the Degree of Protection
39
Post-Connection Check
40
System Integration
41
Web Server
41
Service Interface
43
Fieldbus Systems
44
Operation Options
45
Overview
45
Access to Operating Menu Via Local Display
46
Configuration Options
47
Commissioning
49
Function Check
49
Switching on
49
User Definable Screens
50
Basic Setup
51
Operation
52
Display
52
General Settings
54
Current Inputs
68
Outputs
68
Binary Inputs and Outputs
78
Additional Functions
83
Calibration
113
Diagnostics and Troubleshooting
114
General Troubleshooting
114
Diagnostic Information on Local Display
115
Diagnostic Information Via Web Browser
115
Diagnostic Information Via Fieldbus
115
Adapting the Diagnostic Information
115
Overview of Diagnostic Information
117
Pending Diagnostic Messages
121
Diagnostics List
121
Event Logbook
122
12.10 Simulation
124
12.11 Device Test
126
12.12 Resetting the Measuring Device
127
12.13 Device Information
127
12.14 Firmware History
130
Maintenance
134
Cleaning
134
Repair
136
Spare Parts
136
Return
139
Disposal
139
Accessories
140
Device-Specific Accessories
140
Communication-Specific Accessories
146
Service-Specific Accessories
146
System Components
148
Other Accessories
149
Technical Data
150
Input
150
Digital Inputs, Passive
151
Current Input, Passive
151
Output
152
Digital Outputs, Passive
153
Current Outputs, Active
154
Relay Outputs
154
Protocol-Specific Data
155
Power Supply
158
16.10 Performance Characteristics
160
16.11 Environment
161
16.12 Mechanical Construction
163
Installation and Operation in Hazardous Environment Class I DIV
165
Index
166
Endress+Hauser Liquiline CM444 Operating Instructions Manual (153 pages)
Universal four-wire multichannel controller Field device
Brand:
Endress+Hauser
| Category:
Controller
| Size: 9 MB
Table of Contents
Table of Contents
3
1 Document Information
5
Warnings
5
Symbols
5
Symbols at the Device
5
Documentation
6
2 Basic Safety Instructions
7
Requirements for the Personnel
7
Designated Use
7
Occupational Safety
7
Operational Safety
8
Product Safety
8
3 Device Description
9
Housing Closed
9
Housing Open
9
Slot and Port Assignment
10
Terminal Diagram
11
4 Incoming Acceptance and Product
12
Identification
12
Incoming Acceptance
12
Product Identification
12
Scope of Delivery
13
Certificates and Approvals
13
5 Installation
14
Installation Conditions
14
Mounting Measuring Device
15
Post-Installation Check
18
6 Electrical Connection
19
Connection Conditions
19
Connecting the Measuring Device
20
Connecting the Sensors
26
Connecting Additional Inputs, Outputs or Relays
28
Connecting Digital Communication
32
Hardware Settings
35
Ensuring the Degree of Protection
36
Post-Connection Check
37
7 System Integration
38
Web Server
38
Service Interface
39
Fieldbuses
40
8 Operation Options
42
Overview
42
Access to the Operating Menu Via the Local Display
43
Configuration Options
44
9 Commissioning
47
Function Check
47
Power up
47
Basic Setup
49
10 Operation
50
Display
50
General Settings
52
Current Inputs
64
Outputs
65
Binary Inputs and Outputs
72
Additional Functions
78
11 Calibration
103
12 Diagnostics and Troubleshooting
104
General Troubleshooting
104
Diagnostic Information on the Local Display
105
Diagnostic Information Via Web Browser
105
Diagnostic Information Via Fieldbus
105
Adapting the Diagnostic Information
105
Overview of Diagnostic Information
107
Pending Diagnostic Messages
110
Diagnostics List
110
Event Logbook
111
12.10 Simulation
113
12.11 Device Test
115
12.12 Resetting the Measuring Device
115
12.13 Device Information
115
12.14 Firmware History
117
13 Maintenance
120
Cleaning
120
14 Repairs
122
Spare Parts
122
Return
125
Disposal
125
15 Accessories
126
Protective Cover
126
Post Mounting Kit
126
Measuring Cable
126
Sensors
126
Additional Functionality
131
Software
133
Other Accessories
133
Technical Data
136
Index
149
Advertisement
Endress+Hauser Liquiline CM444 Operating Instructions Manual (64 pages)
Universal four-wire multichannel controller
Brand:
Endress+Hauser
| Category:
Controller
| Size: 5 MB
Table of Contents
Table of Contents
3
Safety Instructions
4
Designated Use
4
Installation, Commissioning and Operation
4
Operational Safety
4
Return
5
Notes on Safety Conventions and Icons
5
Identification
7
Device Designation
7
Scope of Delivery
7
Certificates and Approvals
8
Device Description
8
Housing Closed
8
Housing Open
9
Device Architecture
10
Installation
12
Incoming Acceptance, Transport, Storage
12
Installation Conditions
13
Installation Instructions
15
Post-Installation Check
18
Wiring
19
Quick Wiring Guide: Remote Operation
19
Opening the Housing
22
Cable Mounting Rail
22
Connecting the Cable Shield
23
Cable Terminals
24
Connecting the Supply Voltage
25
Sensor Connection
29
Connecting Additional Inputs, Outputs or Relays
35
Connecting Digital Communication
35
5.10 Post-Connection Check
39
Operation
40
Display and Operating Elements
40
Operation Concept
41
Configuration Options
42
Commissioning
45
Function Check
45
Setting the Bus Address Via the Hardware
45
Switching on the Unit
46
Basic Setup
47
Display
48
Technical Data
51
Input
51
Output
52
Current Outputs, Active
53
Relay Outputs
54
Protocol-Specific Data
55
Power Supply
57
Performance Characteristics
58
Environment
59
Mechanical Construction
60
Index
61
Endress+Hauser Liquiline CM444 Brief Operating Instructions (44 pages)
Universal four-wire multichannel controller
Brand:
Endress+Hauser
| Category:
Control Panel
| Size: 3 MB
Table of Contents
Table of Contents
3
1 About this Document
4
Warnings
4
Symbols
4
Symbols on the Device
5
Documentation
5
2 Basic Safety Instructions
6
Requirements for Personnel
6
Designated Use
6
Workplace Safety
7
Operational Safety
7
Product Safety
7
3 Incoming Acceptance and Product Identification
9
Incoming Acceptance
9
Product Identification
9
Scope of Delivery
10
4 Installation
11
Mounting Conditions
11
Mounting the Measuring Device
12
Post-Installation Check
15
5 Electrical Connection
16
Connecting the Measuring Device
16
Connecting the Sensors
23
Connecting Additional Inputs, Outputs or Relays
27
Connecting PROFIBUS or Modbus 485
30
Hardware Settings
34
Ensuring the Degree of Protection
35
Post-Connection Check
36
6 Operation Options
37
Overview
37
Access to the Operating Menu Via the Local Display
38
7 Commissioning
39
Function Check
39
Switching on
39
Basic Setup
40
Endress+Hauser Liquiline CM444 Brief Operating Instructions (40 pages)
Universal four-wire multichannel controller
Brand:
Endress+Hauser
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Document
4
Warnings
4
Symbols
4
Symbols on the Device
5
Documentation
5
Basic Safety Instructions
6
Requirements of the Personnel
6
Intended Use
6
Workplace Safety
6
Operational Safety
7
Product Safety
7
Incoming Acceptance and Product Identification
8
Incoming Acceptance
8
Product Identification
8
Scope of Delivery
9
Mounting
10
Mounting Requirements
10
Mounting the Measuring Device
11
Post-Mounting Check
14
Electrical Connection
15
Connecting the Measuring Device
15
Connecting the Sensors
22
Connecting Additional Inputs, Outputs or Relays
26
Connecting PROFIBUS or Modbus 485
29
Hardware Settings
33
Ensuring the Degree of Protection
34
Post-Connection Check
35
Operation Options
36
Overview
36
Access to Operating Menu Via Local Display
37
Commissioning
38
Function Check
38
Power-Up
38
Basic Setup
39
Endress+Hauser Liquiline CM444 Operating Instructions Manual (40 pages)
Universal four-wire multichannel controller
Brand:
Endress+Hauser
| Category:
Controller
| Size: 3 MB
Table of Contents
Table of Contents
2
1 Document Information
3
Warnings
3
Symbols Used
3
Documentation
4
2 Basic Safety Instructions
5
Requirements for Personnel
5
Designated Use
5
Occupational Safety
5
Operational Safety
6
Product Safety
6
3 Incoming Acceptance and Product Identification
7
Incoming Acceptance
7
Product Identification
7
Scope of Delivery
8
Certificates and Approvals
8
4 Installation
9
Installation Conditions
9
Mounting the Measuring Device
11
Post-Installation Check
14
5 Electrical Connection
15
Connecting the Measuring Device
15
Connecting the Sensors
23
Connecting Additional Inputs, Outputs or Relays
25
Connecting Digital Communication
28
Hardware Settings
32
Guaranteeing the Degree of Protection
33
Post-Connection Check
33
6 Operation Options
34
Overview
34
Access to the Operating Menu Via the Local Display
35
7 Commissioning
37
Function Check
37
Switching on the Unit
37
Advertisement
Related Products
Endress+Hauser Liquiline CM442R
Endress+Hauser Liquiline CM444R
Endress+Hauser Liquiline CM448R
Endress+Hauser Liquiline CM442
Endress+Hauser Liquiline CM448
Endress+Hauser Liquiline CM44 series
Endress+Hauser Liquiline CA80 series
Endress+Hauser mycom CLM 121
Endress+Hauser mycom CLM 151
Endress+Hauser Mycom CPM 152
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL