Sign In
Upload
Manuals
Brands
Emerson Manuals
Switch
NT5C06B
Emerson NT5C06B Manuals
Manuals and User Guides for Emerson NT5C06B. We have
1
Emerson NT5C06B manual available for free PDF download: Installation And User Manual
Emerson NT5C06B Installation And User Manual (120 pages)
Single Phase −48V 25A Switch Mode Rectifier
Brand:
Emerson
| Category:
Switch
| Size: 0.97 MB
Table of Contents
Table of Contents
7
About this Manual
13
Purpose of this Manual
13
Safety Precautions
13
How this Manual Is Organized
13
Introduction
15
Applications
15
List of Tables
16
Rectifier Models
16
Table 1 - NT5C06B/C Models
16
Table 2 - Rectifier Feature Summary
16
Specifications
17
Mechanical
17
Electrical
17
Rectifier Voltage and Current
17
Table 3 - MPR15/MPR25 Input Current Requirements
17
Output Voltage
18
Output Regulation
18
Output Noise and Ripple
18
Acoustical Noise
19
Efficiency and Power Factor
19
Reliability
19
Heat Dissipation
19
Electromagnetic Interference (EMI)
19
Environmental
19
Operating
19
Transportation
20
Storage
20
Operation
21
Rectifier Operation
21
Display and Rear Interface
22
Display
22
Local Float / Equalize Control
22
Indicator Lamps
22
Figure 1 - NT5C06B/C Rectifier (Front View)
22
Rectifier Failure Alarm (RFA)
23
Fan Failure Alarm
23
Internal High Voltage Shut down (HVSD)
23
Local ON/OFF Control (DC and Optional AC Breakers)
23
Inrush Current Limiting Fuse (F1)
23
Test Points (V+, V-)
24
Current Meter
24
Fan Filter Option
24
Rear Interface
24
Fan Cooling Assembly
24
Figure 2 - Rear Interface
24
Signal Connector
25
Power Interface Edge Connector
25
List of Figures
22
Features
25
Operating Features
25
Monitoring Features
26
Measurement Features
27
Control Features
27
Signal Connections
28
Figure 3 - Signal Connector
29
Rectifier and Controller Interface Connections
30
Power Shelf
31
Mechanical
31
Table 4 - Power Shelf Feature Summary
32
Table 5 - Modular Power Shelf Embedded Application Signal Availability
33
Nt5C10Bm
34
Table 6 - Modular Power Shelf Embedded Application Signal Availability
34
Table 7 - Modular Power Shelf System Application Signal Availability
35
Figure 4 - 19-Inch Power Shelf (Front View)
36
Table 8 - List of Abbreviations Used in Tables 6 and 7
36
Figure 5 - 23-Inch Power Shelf (Front View)
37
Figure 6 - Power Shelf NT5C10BJ or NT5C10BK (Exterior View)
37
Figure 7 - Power Shelf NT5C10BJ or NT5C10BK (Interior View)
37
Electrical
38
Figure 8 - Power Shelf NT5C10BM E/W EQL Switch Assembly
38
Figure 9 - Power Shelf NT5C10CO Equipped with Start Delay LED
38
Environmental
40
Storage
40
List of Procedures
41
Installation and Start-Up Procedures
41
Tools and Test Equipment
41
Installation Procedure
41
Procedure 1 - Power Shelf Installation
41
Figure 10 - 19-Inch Power Shelf
42
Figure 11 - 23-Inch Power Shelf
42
Cabling the Power Shelf
43
Figure 12 - 19-Inch Power Shelf (NT5C10BF and NT5C10BP Only)
43
Shelf Configuration
44
19-Inch System Shelf (NT5C10CA-1/2)
44
19-Inch Embedded Shelf (NT5C10BF-1 and NT5C10BP)
44
19-Inch Embedded Shelf (NT5C10BA-1/2)
44
19-Inch Embedded Shelf (NT5C10BA-3/4)
44
19-Inch Embedded Shelf (NT5C10BA-5/6,NT5C10BB-3/4)
45
19-Inch Embedded Shelf (NT5C10BB-1/2)
45
23-Inch System Shelf (NT5C10CB-1/2, NT5C10CB-5/6, NT5C10CC-1/2, NT5C10CD-1/2) NT5C10CG
45
23-Inch System Shelf (NT5C10CB-3/4, NT5C10CE, NT5C10CF, NT5C10CH)
45
23-Inch Embedded Shelf (NT5C10BC-1/2)
45
23-Inch Embedded Shelf (NT5C10BC-3, NT5C10BD-3)
46
23-Inch Embedded Shelf (NT5C10BM)
46
23-Inch Embedded Shelf (NT5C10BL)
46
23-Inch Embedded Shelf (NT5C10BJ, NT5C10BK)
46
23-Inch System Shelf (NT5C10CO)
47
Figure 13 - System Shelf or Embedded (Left View) Common Bussed AC - Side Access
47
Procedure 2 - Common Bussed AC Connection - Side Access
47
Figure 14 - Extra Ground Connection Mounting Location (Optional)
48
Figure 15 - Embedded Shelf (Left View) - Individual Ac - Side Access Old Vintage
48
Figure 16 - Embedded Shelf (Left View) - Individual AC - Side Access
49
Procedure 3 - Individual AC Connection - Side Access Old Vintage
49
Procedure 4 - Individual AC Connection-Side Access
49
Figure 17 - System or Embedded Shelf (Left View) - Individual AC - Side Access
50
Procedure 5 - Individual AC Connection - Side Access
50
Figure 18 - System Shelf (Left View) - Common Bussed AC - Rear Access
51
Procedure 6 - Common Bussed AC Connection - Rear Access
51
Figure 19 - System or Embedded Shelf (Right View) - DC Connecting - Side Access
52
Procedure 7 - DC Connection - Side Access
52
Power Plant Interface - Signal Cabling
53
Figure 20 - System or Embedded Shelf (Right View) - DC Cabling - Rear Access
53
Procedure 8 - DC Connection - Rear Access
53
UM5C06B / C ( 169-2071-500 ) P0711722 Standard 10.00 May
54
Table 9 - Standard System Application Signal Cable Connections
54
Table 10 - J1, J2 and J3 Connector Pin Assignment
56
Installing the Rectifier
57
Procedure 9 - Rectifier Installation
57
Cabling the Rectifier
58
UM5C06B / C ( 169-2071-500 ) P0711722 Standard 10.00 May
58
Figure 21 - Rectifier AC and DC Power (Internal) Cabling Harness
58
LVD Installation in the Shelf
59
Figure 22 - Embedded Shelf - LVD Connections - Rear Access
59
Procedure 10 - LVD Installation in the Shelf
59
Start-Up Procedure
60
Factory Set Voltage Limits
60
Figure 23 - Embedded Shelf - LVD Connections - Side Access
60
Rectifier Power-Up
61
Procedure 11 - Rectifier Power-Up
61
HVSD Adjustment
62
Figure 24 - Embedded Shelf Quick Disconnect for Sense (Sectional View)
62
Procedure 12 - HVSD Adjustment
62
Float Voltage Adjustment
63
Equalize Voltage Adjustment
63
Procedure 13 - Float Voltage Adjustment
63
Procedure 14 - Equalize Voltage Adjustment
63
Parallel Verification
64
Low Voltage Disconnect (LVD)
65
Procedure 15 - Parallel Verification
65
Adjustment for the 50 a LVD Unit Rel. 02, 02A, 3 & 3A
66
Procedure 16 - Low Voltage Disconnect Adjustment
66
Procedure 17 - LVD 50 a Adjustment for Unit Release 02, 02A, 3 and 3A
66
Low Voltage Alarm (LVA) Adjustment
67
Lvd/Low Voltage Disconnect / Reconnect (LVDR) Adjustment
67
Procedure 18 - Low Voltage Alarm Adjustment
67
Procedure 19 - Low Voltage Disconnect/Reconnect Adjustment
67
Rectifier Replacement/Add-On Procedure
68
Low Voltage Disconnect
69
Electrical
69
Environmental
69
Storage
69
DC Cabling
70
Control and Monitoring Signals
70
Figure 25 - Low Voltage Disconnect Connections
70
Figure 26 - Low Voltage Control and Monitoring Signals
70
Operation
71
Test Feature
71
Signal Connections
71
Maintenance
73
Rectifier
73
Procedure 20 - Float/Equalize and Remote Equalize
73
Filter
74
Fan Cooling
74
Storage
74
Power Shelf
74
Low Voltage Disconnect
75
Troubleshooting
75
Rectifier Fail Alarm
75
Load Sharing
76
Fan Failure
76
Fan Replacement Procedure
76
Procedure 21 - Fan Replacement
76
Figure 27 - Fan Assembly
78
Low Voltage Disconnect
78
Fault Diagnosis
79
Applications
81
Figure 28 - System Application Power Shelf MPS50S and MPS75S
81
Figure 29 - Embedded Application Power Shelf MPS50E and MPS75E
82
Figure 30 - Low Voltage Disconnect
83
Figure 31 - Power Shelf Wiring Figure Index
84
Nt5C10Cg, Nt5C10Ch
84
Figure 32 – NT5C10BA-5/6 and NT5C10BB-1/2, 3/4 Embedded Application
85
Figure 33 – NT5C10BA-1/2 Embedded Application
86
Nt5C10Cc-1/2, Nt5C10Cd-1/2, Nt5C10Ce-1/2, Nt5C10Cf-1/2 Nt5C10Cg, Nt5C10Ch
90
Appendix A: NT5C10BF-1 and NT5C10BP
101
Purpose
101
Application
101
FTIP Application
101
Table 11 - Application Configuration Table
101
Alarms
102
Factory Set Voltage Limits
102
Power and Signal Lead Termination
102
FTOP Application
102
Alarms
103
Power and Signal Lead Termination
103
Factory Set Voltage Limits
103
Table 12 - Application Configuration Table
103
General Requirements
104
Power Shelf Size
104
Shelf Labeling
104
Appendix B: NT5C10CO Shelf
105
General
105
NT5C10CO Power Shelf
105
Description
105
Technical Specifications
106
Power-Up and Verification
107
Verification
107
Procedure 22 - Power-Up and Verification
107
Adjustment and Verification
108
Procedure 23 - Adjustment and Verification
108
UM5C06B / C ( 169-2071-500 ) P0711722 Standard 10.00 May
108
Troubleshooting
111
Table 13 - Systems Equipped with NT5C10CO Power Shelf Fault Diagnosis
111
Appendix C: Recommended Replacement Parts
113
Appendix D: Technical Service Assistance
115
Abbreviations and Acronyms
117
Advertisement
Advertisement
Related Products
Emerson NT5C05CA
Emerson NT5C05CB
Emerson NT5C05CC
Emerson NT5C06C
Emerson Liebert NX 400V
Emerson Liebert NXL 400 kVA
Emerson Liebert NX 40kVA
Emerson Liebert NXL 500 kVA
Emerson Net Safety JB-MPH
Emerson Net Safety JB-MPR
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL