Sign In
Upload
Manuals
Brands
Electro Industries/GaugeTech Manuals
Gateway
ProtoCom
Electro Industries/GaugeTech ProtoCom Manuals
Manuals and User Guides for Electro Industries/GaugeTech ProtoCom. We have
1
Electro Industries/GaugeTech ProtoCom manual available for free PDF download: Installation & Operation Manual
Electro Industries/GaugeTech ProtoCom Installation & Operation Manual (118 pages)
Brand:
Electro Industries/GaugeTech
| Category:
Gateway
| Size: 13 MB
Table of Contents
Customer Service and Support
5
Use of Product for Protection
8
Statement of Calibration
8
Disclaimer
8
Safety Symbols
9
UL Compliance
9
Our Focus at Electro Industries/Gaugetech (EIG)
10
Table of Contents
11
1 : Introduction to the Protocom/Protocom-Lon
15
Overview of the Protocom/Protocom-Lon Gateway
15
EIG Devices and Available Point Count
16
Specifications
17
Protocom/Protocom-Lon Dimensions
18
Electrical Connections
19
Use of DIP Switches
21
Removing the Top Cover from the Protocom/Protocom-Lon (ONLY if Necessary)
22
1: Replacing the Top Cover
25
Web Configurator
25
Protocom/Protocom-Lon Installation
27
1: Mounting on a DIN Rail
27
2: Mounting on a Panel
28
Navigating this Manual
29
2 : Using the Protocom/Protocom-Lon
31
Step One - Configure Modbus Communication Settings
31
Step Two - Select the Desired Field BAS Protocol (Protocom Only)
33
Step Three - Enable Auto-Discovery
34
Step Four - Set MAC Address/Device Instance/Node-ID (Proto-Com Only)/Ip Address
35
1: Set MAC Address - for Bacnet MS/TP Protocol Only
35
Protocols
36
1: Change Node_Offset Value
36
3: Device Node-ID for Metasys N2, Modbus/Tcp, and DF1
37
Protocols
37
4: Set IP Address for Ethernet Devices Connected to Protocom
38
Step 5: Set the Baud Rate for Bacnet MS/TP and DF1 Protocols
39
Step 6 - Connect the Protocom/Protocom-Lon to the Meter
40
1: Biasing the Modbus RS485 Network (Only if Necessary)
42
(Only if Necessary)
43
Step 7 - Connect to the Rs485/Lonworks Network
44
MS/TP, Metasys N2, DF1, or Lonworks)
44
Step 8 - Connect Power to the Protocom/Protocom-Lon
45
Step 9 - Turn off Auto-Discovery after Completion to Save Configuration
46
Step 10: Additional Configuration
47
1: Use the Web Configurator to Configure IP Address for Bacnet IP and Ethernet/Ip
47
2: Set up a Password
51
3: Configure the Protocom-Lon
53
4: Configure the Ethernet Device Connection
55
3 : Troubleshooting
57
LED Diagnostics for Modbus RTU Communications between Protocom/Protocom-Lon and Devices
57
1: no Communication on Modbus RTU (Meter) Side
58
2: Field Communication Problems
58
Lost or Incorrect IP Address
59
Clearing Profiles
61
A: Protocol Data Points for EIG Meters
63
A.1: Shark® 100 Meter
64
A.2: Shark® 200 Meter
66
A.3: Nexus® 1252/1262/1272 Meters
69
A.4: DMMS 425 Meter
71
A.5: Nexus® 1500 Meter
72
A.6: MP200-Y Metering System
74
A.7: MP200-S Metering System
78
A.8: Shark® 250/270 Meter
99
A.9: PQMII Meter
102
B: MAC Address DIP Switch Settings
105
C: Validating the Protocom in the Field (Bacnet MS/TP or Bacnet/Ip
111
C.1: Download the CAS Explorer and Request an Activation Key
111
C.2: CAS Bacnet Setup
113
C.2.1: CAS Bacnet MS/TP Setup
113
C.2.2: CAS Bacnet/Ip Setup
116
Advertisement
Advertisement
Related Products
Electro Industries/GaugeTech ProtoCom-Lon
Electro Industries/GaugeTech Categories
Measuring Instruments
Transducer
Heater
Antenna
Gateway
More Electro Industries/GaugeTech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL