Sign In
Upload
Manuals
Brands
EDM Manuals
Control Panel
Solution 4+4
User Manuals: EDM Solution 4+4 Control Panel
Manuals and User Guides for EDM Solution 4+4 Control Panel. We have
1
EDM Solution 4+4 Control Panel manual available for free PDF download: Installation Manual
EDM Solution 4+4 Installation Manual (174 pages)
Brand:
EDM
| Category:
Control Panel
| Size: 1 MB
Table of Contents
Table of Contents
7
Introduction
13
Introduction
14
Features
15
Quick Start
16
Zone Defaults
16
Programming
17
Programming
18
Programming with the Remote Codepad
19
Programming with the Hand Held Programmer
20
Programming with the Programming Key
21
Programming Option Bits
21
Installer's Programming Commands
22
Command 958 - Enable/Disable Zone Status Mode
22
Command 959 - Test Programming Key
23
Command 960 - Exit Installer's Programming Mode
23
Command 961 - Reset Control Panel Back to Factory Default Settings
23
Command 962 - Copy Control Panel Memory to Programming Key
24
Command 963 - Copy from Programming Key to Control Panel
25
Command 964 - Erase Programming Key
26
Command 965 - Set up Domestic Dialling Format
27
Command 966 - Enable/Disable Automatic Stepping of Locations
28
Command 999 - Display Software Version Number
29
Disable Factory Default
29
Defaulting the Control Panel
30
System Indicators and Operations
31
System Indicators and Operations
32
CP5 Eight Zone Codepad
32
Zone Indicators
32
AWAY Indicator
32
STAY Indicator
32
MAINS Indicator
33
FAULT Indicator
33
Audible Indicators
33
CP5 Eight Zone LCD Codepad
34
Zone Indicators
34
AWAY Indicator
34
STAY Indicator
34
System Disarmed
35
MAINS Indicator
35
Zone Isolating Mode
35
FAULT Indicator
35
Programming Mode
35
Off Indicator/Zone Sealed
36
On Indicator/Zone in Alarm
36
Audible Indicators
36
System Operations
37
Arming the System in AWAY Mode
37
Forced Arming
37
Disarming the System from AWAY Mode
37
Arming the System in STAY Mode
38
Forced Arming
38
Disarming the System from STAY Mode
39
Codepad Duress Alarm
40
Codepad Panic Alarm - Versions up to 1.26
40
Codepad Panic Alarm - Version 1.27 Onwards
40
Codepad Fire Alarm - Version 1.27 Onwards
40
Codepad Medical Alarm - Version 1.27 Onwards
40
Isolating Zones
41
Standard Isolating
41
Code to Isolate
42
Fault Analysis Mode
43
Fault Descriptions
44
Low Battery
44
Date and Time
44
Sensor Watch
44
Horn Speaker Monitor
44
Reserved
44
E 2 Fault
44
Communication Failure
44
AC Mains Failure
44
System Functions
45
System Functions
46
Installer Code Functions
46
Fault Analysis Mode
47
How to Enter Fault Analysis Mode
47
Reserved
47
Set the Number of Days until the First Test Report
48
Event Memory Recall Mode
49
Walk Test Mode
50
Satellite Siren Service Mode
50
Initiate Modem Call
50
How to Initiate a Modem Call
50
Turning Telephone Monitor Mode On/Off
51
Reserved
51
Send Test Report
51
How to Initiate a Test Report
51
Master Code Functions
52
Reserved
52
Changing and Deleting User Codes
53
Changing Domestic Phone Numbers
55
Event Memory Recall Mode
56
Walk Test Mode
57
Fault Analysis Mode
58
Setting the Date and Time
59
Turn Day Alarm on and off
59
Reset Latching Outputs
60
Initiate Modem Call
60
Hold down Functions
61
Arm the System in AWAY Mode
61
Arm the System in STAY Mode
61
Horn Speaker Test
61
Bell Test
61
Strobe Test
62
Turning Day Alarm on and off
62
Fault Analysis Mode
62
Initiate a Modem Call
63
Reset Latching Outputs
63
Codepad Beeper Tone Change
63
Initiate a Test Report
63
Remote Operations
65
Remote Operations
66
Remote Arming Via the Telephone
66
Upload/Download Via Alarm Link Software
67
Remote Connect
67
Remote Connect with Customer Control
67
Remote Connect Without Callback Verification
67
Remote Connect with Callback Verification
68
Dialler Reporting Formats
69
Dialler Reporting Formats
70
Contact ID Format
70
Point ID Codes
71
Event Codes
72
General Reporting Formats
73
Securitel
75
Domestic Reporting Format
76
Domestic Dialling Function
76
Programming Domestic Reporting
77
Basic Pager Reporting Format
79
Base Station Information
81
Base Station Information
82
Primary Telephone Number
83
Secondary Telephone Number
83
Callback Telephone Number
83
Dialling Format
84
Handshake Tone
84
Transmission Format
85
Transmission Speed
85
Receivers and Their Formats
86
Subscriber ID Number
86
Ring Count
87
Answering Machine Bypass
87
User Codes
89
Access Codes
90
Installer Code
90
User Codes
90
User Code Priority
91
Arm and Disarm
91
Arm Only
91
Patrolman Code
91
Arm and Disarm + Code to Isolate
91
Patrolman Code + Code to Isolate
91
Arm and Disarm + Master Code Functions
91
Arm and Disarm + Master Code Functions + Code to Isolate
91
Code Retries
92
Zone Information
93
Zone Information
94
Day Alarm Mask
94
Day Alarm Resetting
94
Day Alarm Latching
94
Day Alarm Operation
95
EOL Resistor Value
96
Connections of Split EOL Resistors Using N/O Contacts
97
Zone Programming
98
Zone Operating Information
98
Zone Reporting Information
98
Tamper Zones
99
Zone Defaults
100
Zone Types
100
Instant Zone
100
Handover Zone
100
Delay-1 Zone
100
Delay-2 Zone
100
Reserved
100
Reserved
101
Instant Zone + Isolated in STAY Mode
101
Handover Zone + Isolated in STAY Mode
101
Delay-1 Zone + Isolated in STAY Mode
101
Delay-2 + Isolated in STAY Mode
101
Keyswitch Zone
101
Hour Burglary Zone
101
Hour Fire Zone
101
Chime Zone
101
Zone Not Used
101
Zone Options
102
Lockout Siren & Lockout Dialler
102
Silent Alarm
103
Sensor Watch
103
Keyswitch Zone Options
104
Latching Arm and Disarm in AWAY Mode
104
Latching Arm in AWAY Mode
104
Latching Disarm from AWAY Mode or STAY Mode
104
Latching Arm and Disarm in STAY Mode
104
Latching Arm in STAY Mode
104
Momentary Arm and Disarm in AWAY Mode
105
Momentary Arm in AWAY Mode
105
Momentary Disarm from AWAY Mode or STAY Mode
105
Momentary Arm and Disarm in STAY Mode
105
Momentary Arm in STAY Mode
105
Zone Pulse Count
106
Zone Pulse Count Handover
106
Zone Pulse Count Time
106
System Status Information
107
System Status Information
108
Zone Bypass Reports
108
Zone Trouble Reports
108
Codepad Duress Report
109
Codepad Panic Report
110
Access Denied
111
AC Fail Report
112
Low Battery Report
112
Sensor Watch Report
113
Open/Close Reports
113
Test Reporting Time
114
Programmable Outputs
115
Programmable Outputs
116
Output Defaults
116
Redirecting Outputs to the Codepad Buzzer
117
Output Event Types
118
Output Polarity
123
Output Not Used
123
Normally Open, Going Low
123
Normally Open, Pulsing Low
123
Normally Open, One Shot Low
123
Normally Open, One Shot Low with Retrigger
123
Normally Open, One Shot Low with Reset
123
Normally Open, One Shot Low with Alarm
124
Normally Open, Latching Low
124
Normally Low, Going Open
124
Normally Low, Pulsing Open
124
Normally Low, One Shot Open
124
Normally Low, One Shot Open with Retrigger
124
Normally Low, One Shot Open with Reset
124
Normally Low, One Shot Open with Alarm
124
Normally Low, Latching Open
124
Timing of Outputs
125
Pulsing Polarities
125
One Shot Polarities
126
System Event Timers
127
System Event Timers
128
How to Program Entry/Exit Timers
128
Entry Time
128
Entry Timer 1
128
Entry Timer 2
128
Exit Time
129
Entry Guard Timer for STAY Mode
129
Sensor Watch Time
129
Codepad Lockout Time
130
Siren Run Time
130
Siren Sound Rate
130
Swinger Shutdown Count
131
System Time
132
Setting the Date and Time
132
Options Bits
133
Dialler Options
134
Dialler Options 1
134
Enable Dialler Reporting Functions
134
Disable Dialler Reporting Functions
134
Enable Remote Arming Via the Telephone
134
Enable Upload/Download Via Alarm Link
134
Terminate "Alarm Link" Session on Alarm
134
Dialler Options 2
135
Send Open/Close Reports Only if a Previous Alarm Has Occurred
135
Reserved
135
Send Open/Close Reports When in STAY Mode
135
Delay Siren until Transmission Complete
135
System Options 1
136
Enable Forced Arming
136
Enable EDM Smart Lockout
136
Enable Monitoring of Horn Speaker
136
Allow Horn Speaker Beeps for Remote Control Operations
136
System Options 2
137
Enable Radio Key/Keyswitch Interface or Night Arm Station
137
Enable Handover Delay to be Sequential
137
Enable Codepad Panic to be Silent
137
Enable Access Denied to be Silent
137
System Options 3
138
Reserved
138
Ignore AC Mains Fail Indication
138
Enable Zone Pulse Count Handover
138
Consumer Options 1
139
Send Test Reports Only if the System Is Armed
139
Enable Operation of Siren & Strobe in STAY Mode
139
Enable Answering Machine Bypass Only When Armed
139
Enable Codepad Extinguish Mode
139
Consumer Options 2
140
Reserved
140
Enable Single Button Arming in AWAY Mode or STAY Mode
140
Enable Single Button Disarming from STAY Mode
140
Enable Alarm Memory Reset on Disarm
140
Optional Equipment
141
Optional Equipment
142
Terminals and Descriptions
147
Terminal Definitions and Descriptions
148
Glossary of Terms
149
Solution 4+4 Wiring Diagram
151
Solution 4+4 Component Overlay
152
Telecom Connection Diagrams
153
Appendices
155
Telephone Anti-Jamming
156
Appendix A
156
Test Reports Only When Armed
157
Appendix B
157
Specifications
159
Warranty Statement
160
Specifications
160
Software Version Number
160
Advice to Users
161
New Zealand Telepermit Notes
161
Programming Sheets
163
Index
169
Advertisement
Advertisement
Related Products
EDM Solution 862
EDM Solution-16 Safecom
EDM Solution Ultima 844
EDM Solution Ultima 880
EDM Solution 6+6 Wireless-AE
EDM Solution-8
EDM Solution 8
EDM M1
EDM Categories
Fan
Control Panel
Security System
Kitchen Appliances
Accessories
More EDM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL