Table of Contents
Important Safety Instructions
2
Table of Contents
3
1 Introduction
11
Basic System Configurations
12
Using this Manual
13
Appendix A - Installation Information
14
Conventions Used in this Manual
14
Warranty
14
Safety Warnings
15
Important Safety Instructions
15
For more Information
16
Getting Help
16
Section I - Installation
17
2 UPS Installation Plan and Unpacking
19
Creating an Installation Plan
19
Preparing the Site
19
Environmental Considerations
20
Preparing for Wiring the UPS System
20
Inspecting and Unpacking the UPS Cabinet
21
3 Installing the UPS System
23
Preliminary Installation Information
23
UPS Cabinet Installation
23
Unloading the Powerware 9390 UPS Cabinet from the Pallet
24
Figure 3-1. Removing the Front Shipping Bracket on the Powerware 9390 UPS
25
Figure 3-2. Removing the Rear Shipping Bracket on the Powerware 9390 UPS
26
Battery Cabinet Installation
27
Installing UPS External and Battery Power Wiring
28
Integrated Accessory Cabinet Installation
28
Integrated Distribution Cabinet Installation
28
UPS Sidecar Wiring
28
Installing Interface Connections
31
TB1 and TB2 Connections
31
TB1 Battery Cabinet Connections
32
X-Slot Connections
33
Installing Accessories and Parallel System Control Wiring
34
Initial Startup
34
Completing the Installation Checklist
34
Installation Checklist
35
4 Batteries
39
Important Safety Instructions
39
Installing Batteries
40
Recycling the Used Battery or UPS
40
Figure 5-1. REPO Switch
41
5 Installing a Remote Emergency Power-Off Switch
41
6 Installing Options and Accessories
45
Installing a Powerware Hot Sync CAN Bridge Card
45
Figure 6-1. Powerware Hot Sync CAN Bridge Card
45
Installing Parallel System Control Wiring
46
Installing a Remote Monitor Panel
47
Installing a Relay Interface Module
48
Installing a Supervisory Contact Module
50
Figure 6-2. Supervisory Contact Module II TB2
51
Section II - Operation
53
7 Understanding UPS Operation
55
Looking Inside the UPS System
55
Figure 7-1. Main Elements of the UPS System
55
Single Module Reverse Transfer (RT)
56
Single Module RT Modes
56
Normal Mode - RT
58
Figure 7-2. Path of Current through the UPS in Normal Mode - RT
58
Figure 7-3. Path of Current through the UPS in Bypass Mode - RT
60
Figure 7-4. Path of Current through the UPS in Battery Mode - RT
62
Multiple Module Parallel System
63
Multiple Module Parallel System Modes
64
Normal Mode - Parallel
65
Figure 7-5. Path of Current through the Upms in Normal Mode - Parallel
65
Bypass Mode - Parallel
66
Figure 7-6. Path of Current through the Upms in Bypass Mode - Parallel
66
Battery Mode - Parallel
68
Figure 7-7. Path of Current through the Upms in Battery Mode - Parallel
68
Functional Description
69
Input Rectifier
69
Inverter
69
Battery Charger and Advanced Battery Management
69
Bypass
70
Batteries
70
8 Features, Options, and Accessories
71
11 Using Features and Options
71
UPS Standard Features
71
Control Panel
71
Customer Interface
71
Alarm Contact
71
Building Alarm Monitoring
71
Connectups-X Web/Snmp Card X-Slot Card
71
X-Slot Communication Bay
71
Advanced Battery Management
72
Installation Features
72
Lansafe Power Management Software
72
Options and Accessories
72
Integrated Battery Cabinets
72
Integrated Distribution Cabinet
72
Integrated Accessory Cabinet (IAC-B, IAC-T, and IAC-D)
73
Mini-CSB
73
Optional X-Slot Cards
73
Powerware Hot Sync Parallel System
73
Sync Control
73
Relay Interface Module
74
Remote Monitor Panel
74
Supervisory Contact Module
74
Symbols, Controls, and Indicators
74
9 Using the Control Panel
75
Figure 9-1. UPS Control Panel
75
Figure 9-2. Parts of the LCD
76
Using the LCD and Pushbuttons
76
Using the Main Menu
77
Figure 9-3. Main Menu and MIMIC Screen (Normal Mode)
77
MIMIC Screen
77
Event Screens
78
Figure 9-4. Active Events Screen
78
Figure 9-5. History Screen
79
Figure 9-6. Unit Output Meter Screen
80
Unit Meter Screens
80
Figure 9-7. Unit Input Meter Screen
81
Figure 9-8. Unit Bypass Meter Screen
81
Figure 9-10. Unit Output Current (Load) Meter Screen
82
Figure 9-9. Unit Battery Meter Screen
82
Figure 9-11. Battery Discharge Log Summary Screen
83
Figure 9-12. Battery Discharge Log Screen
84
Figure 9-13. KW Demand Log Summary Screen
85
Figure 9-14. KW Demand Log Screen
86
Figure 9-15. Current KW Demand Log Setup Screen 1
87
Figure 9-16. Current KW Demand Log Setup Screen 2
88
Figure 9-17. Time Interval Monitored Setup Screen
89
Figure 9-18. Time Interval Monitored Setup Save Screen
90
Figure 9-19. Maximum Level (KW) Setup Screen
91
Figure 9-20. Maximum Level (KW) Setup Save Screen
92
Figure 9-21. Maximum Current Log Summary Screen
93
Figure 9-22. Maximum Current Log Screen (Three-Phase Measurement)
94
Figure 9-23. Maximum Current Log Screen (Individual Phase Measurement)
95
Figure 9-24. Maximum Current Log Setup Screen 1
95
Figure 9-25. Maximum Current Log Setup Screen 2
96
Figure 9-26. Time Interval Monitored Setup Screen
97
Figure 9-27. Time Interval Monitored Setup Save Screen
98
Figure 9-28. Maximum % of Full Load Setup Screen
99
Figure 9-29. Maximum % of Full Load Setup Save Screen
100
Figure 9-30. Calculation Method Setup Screen
101
Figure 9-31. System Meters Screen
102
System Meters Screens
102
Figure 9-32. Total System Output Meter Screen
103
Figure 9-33. Output Unit X Meter Screen
104
Figure 9-34. Input Unit X Meter Screen
105
Figure 9-35. Bypass Unit X Meter Screen
105
Figure 9-36. Battery Unit X Meter Screen
106
Figure 9-37. Output Current (Load) Unit X Meter Screen
106
Figure 9-38. System Setup Level 0 Screen
107
Figure 9-39. Contrast Adjust Screen
108
Figure 9-40. Versions Screen
109
Figure 9-41. Unit Type Screen
109
Figure 9-42. Enter Password Screen
110
System Setup Level 1 Screens
110
Figure 9-43. System Setup Level 1 Screen
111
Figure 9-44. Change Password Screen
112
Figure 9-45. Change Password Save Screen
113
Figure 9-46. Time Format Screen
114
Figure 9-47. Set Date and Time MM/DD/YYYY Screen
115
Figure 9-48. Set Date and Time DD/MM/YYYY Screen
116
Figure 9-49. COM Port Setup Screen
117
Figure 9-50. COM Setup Screen
118
Figure 9-51. System Controls Screen 1
119
Figure 9-52. System Controls Screen 2
120
Figure 9-53. Load off Screen
121
Reading the Status Indicators
122
10 UPS Operating Instructions
123
Single Module Operation
123
Starting the UPS in Normal Mode
123
Starting the UPS in Bypass Mode
124
Starting the Power Module
125
Transfer from Normal to Bypass Mode
125
Transfer from Bypass to Normal Mode
126
Transfer from Normal to Bypass Mode and Shut down UPS
126
UPS and Critical Load Shutdown
127
Charger Control
127
Using the UPS LOAD off Pushbutton
128
Using the Remote Emergency Power-Off Switch
129
Multiple Module Parallel Operation
130
Starting the Parallel System in Normal Mode
130
Starting the Parallel System in Bypass Mode
131
Transfer Parallel System from Normal to Bypass Mode
132
Transfer Parallel System from Bypass to Normal Mode
132
Single UPM Shutdown
133
Restarting a Single UPM
133
Parallel System and Critical Load Shutdown
134
Using the UPS LOAD off Pushbutton
135
Using the Parallel System Remote Emergency Power-Off Switch
136
General Purpose Relay Contact
137
Figure 11-1. Remote Monitor Panel II
138
Figure 11-2. Relay Interface Module II
140
Figure 11-3. Supervisory Contact Module II
141
12 Responding to System Events
143
General
143
System Event Horns
143
System Event Indicators
143
System Event Messages
143
13 Communication
153
X-Slot Cards
153
Figure 13-1. Optional X-Slot Cards
154
Lansafe Power Management Software
154
Remote Notification
154
Terminal Mode
155
Display UPS Control Panel
155
Event History Log
156
Figure 13-2. Sample Event History Log
157
14 Maintaining the UPS System
159
Important Safety Instructions
159
Performing Preventive Maintenance
160
DAILY Maintenance
160
ANNUAL Maintenance
161
BATTERY Maintenance
161
Maintenance Training
161
MONTHLY Maintenance
161
15 Product Specifications
163
Model Numbers
163
Single Module Specifications
163
UPS System Input
163
Environmental
164
UPS System Output
164
Battery
165
Environmental
165
Module Tie Cabinet Input
165
Module Tie Cabinet Output
165
Multiple Module Parallel Specifications
165
UPM Input
165
UPM Output
165
Battery Cabinet
168
Supervisory Contact Module
217
Front View
219
Advertisement
Advertisement
Related Products
Eaton Powerware 9390-80/40
Eaton Powerware 9390-80/50
Eaton Powerware 9390-80/60
Eaton Powerware 9390 UPS Sidecar
Eaton Powerware 9390 IAC-D
Eaton Powerware 9390-120/100
Eaton Powerware 9390-120/120
Eaton Powerware 9390-160/160
Eaton Powerware 9390 100
Eaton Powerware 9390 160
Eaton Categories
UPS
Circuit breakers
Switch
Industrial Equipment
Industrial Electrical
More Eaton Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL