Sign In
Upload
Manuals
Brands
Dynisco Manuals
Computer Hardware
UPR700
Dynisco UPR700 Manuals
Manuals and User Guides for Dynisco UPR700. We have
1
Dynisco UPR700 manual available for free PDF download: Installation And Operation Manual
Dynisco UPR700 Installation And Operation Manual (73 pages)
Brand:
Dynisco
| Category:
Computer Hardware
| Size: 0 MB
Table of Contents
Table of Contents
2
Quick Start Instructions
3
Mounting
3
Wiring
4
Scaling
4
Calibration and Operation
4
Index
5
Product Codes
6
Introduction
6
Main Power Supply & Environmental Specification
7
Mechanical Specifications
7
Specification
7
Display Specification
8
Indicators
8
Primary Input Specification
8
Optional Secondary Input Specification
9
Input Impedance
9
Input Protection
9
Sampling Time
9
Primary & Secondary Inputs Common Specification
10
Digital Input Specification
10
Optional Serial Communication Interface Specification
11
Alarms Specification
11
Main Analog Output Specification
12
Second Analog Output Specification
12
Main & Second Analog Outputs Common Specification
13
Block Diagram of Electronics Layout
13
Model UPR700 Outline Drawing
14
Unpacking
15
Dimensional Information
15
Hardware
15
UPR700 Wiring - 4-20Ma Transmitter Internal 24 VDC Power Supply
16
Mounting and Wiring
18
Relay Outputs
19
Power Line
19
Terminal Assignments
20
Wiring Conversion Table
21
Getting Ready
22
Configuring the UPR700
22
Start up Procedures
22
Keyboard Description
23
Parameters
24
Operating Mode Description
24
Configuration
24
Parameter Configuration Procedures
25
Setting the Logic Input Configuration
25
Setting the Logic Input Status
26
Setting Peak Detection
26
Setting the Line Frequency
26
Setting the Display Filter
26
Setting the Primary Input Type for a Strain Gage Transducer
27
Primary Input Setup
27
Parameter Table
27
UPR700 Board Location
28
Input/Output Jumper Location
29
Setting the Shunt Calibration for Strain Gage Transducers
29
Setting the Primary Input Type for an Amplified Transmitter
30
Input Selection J84 for Amplified Input
30
Setting the Primary Input Full-Scale Value
31
Setting the Primary Input Low-Scale Value
31
Setting the Primary Input Decimal Place
31
Setting the Primary Input Failsafe Mode
31
Secondary Input Setup
32
Setting the Secondary Input Type
32
Secondary Input Jumper Location
33
Secondary Input Selection W21
33
Setting the Secondary Input Scale and Decimal Point
34
Setting the Thermocouple Type and Units
34
Setting the Secondary Input Failsafe Mode
34
Setting the Alarms
35
Setting Alarm Type
35
Setting the Reset Mode for Alarms
36
Setting the Hysteresis for Alarm
36
Setting the Filtering for Alarm 1
36
Setting the Failsafe Mode for Alarms
37
Setting the Alarms Value
37
Setting the Alarms Mask Reset Type
37
Main and Secondary Analog Output Setup
37
Setting the Main Analog Output Type
38
Setting the Main Analog Output Link
38
Setting the Main Analog Output Range Low
38
Setting the Main Analog Output Range High
38
Main Analog Output Jumper Location
39
Secondary Analog Output Jumper Location (Optional)
39
CPU Board DIP Switch Locations
40
Setting the Main Analog Output Filter
40
Setting the Security Codes
40
Setting the Security Codes for Level a
41
Setting the Security Codes for Level B
41
Setting the Security Codes for Level C
41
Primary Input Calibration
42
Operation
42
Setting the Internal Dip Switch for Instrument Calibration
44
Instrument Calibration
44
General Calibration Procedurte
45
Calibration Parameters Summary
46
Serial Communication Interface Address
47
Protocol Type
47
Communication Type
47
Communication Baud Rate
47
Error During EEPROM Access
48
Wrong Zero Measure
48
Error Codes and Troubleshooting
48
Error Codes
48
Wrong Value of EEPROM Protect Register
49
Instrument Maintenance
49
Normative References
50
Parameter Group Menus
51
Group 1 Default Parameters
52
ALARMS MASK RESET - Group 1
52
ALARM 3 THRESHOLD - Group 1
53
ALARM 2 THRESHOLD - Group 1
53
ALARM 1 THRESHOLD - Group 1
53
SECURITY - Group 1
53
Group 2 Default Parameters
54
Group Access Number
54
ZERO CALIBRATION - Group 2
54
SPAN CALIBRATION - Group 2
54
ALARM 2 FILTER - Group 2
55
ALARM 3 FILTER - Group 2
55
MAIN ANALOG OUTPUT FILTER - Group 2
55
SECOND ANALOG OUTPUT FILTER - Group 2
55
PRIMARY INPUT DECIMAL POINT POSITION - Group 3
56
PRIMARY INPUT FULL SCALE VALUE - Group 3
56
Group 3 Default Parameters
56
PRIMARY INPUT LOW SCALE VALUE - Group 3
56
SECONDARY INPUT RANGE LOW - Group 3
57
SECONDARY INPUT RANGE HIGH - Group 3
57
SECONDARY INPUT DECIMAL POINT POSITION - Group 3
57
ALARM 1 INPUT CHANNEL LINK - Group 3
57
ALARM 3 TYPE - Group 3
58
MAIN ANALOG OUTPUT LINK - Group 3
58
ALARM 3 INPUT CHANNEL LINK - Group 3
58
ALARM 2 TYPE - Group 3
58
MAIN ANALOG OUTPUT RANGE HIGH - Group 3
59
SECONDARY ANALOG OUTPUT LINK - Group 3
59
SECONDARY ANALOG OUTPUT RANGE LOW - Group 3
59
SECOND ANALOG OUTPUT RANGE HIGH - Group 3
59
COMMUNICATION TYPE - Group 3
60
COMMUNICATION BAUD RATE - Group 3
60
LOADING DEFAULT DATA - Group 3
60
SHUNT CALIBRATION - Group 4
60
ALARM 1 RESET MODE - Group 4
61
ALARM 1 HYSTERESIS - Group 4
61
PRIMARY INPUT FAIL SAFE - Group 4
61
SECONDARY INPUT FAIL SAFE - Group 4
61
ALARM 2 RESET MODE - Group 4
62
ALARM 2 FAILSAFE MODE - Group 4
62
ALARM 3 HYSTERESIS - Group 4
62
ALARM 3 RESET MODE - Group 4
62
LOGIC INPUT CONFIGURATION - Group 4
63
LOGIC INPUT STATUS - Group 4
63
PEAK DETECTION - Group 4
63
LINE FREQUENCY - Group 4
63
MAIN ANALOG OUTPUT SELECTION - Group 5
64
Group 5 Default Parameters
64
SECONDARY INPUT SELECTION - Group 5
64
PRIMARY INPUT SELECTION - Group 5
64
Group 6 Security Codes Setting
65
LOADING DEFAULT DATA - Group 5
65
Security Code - Level a
65
Security Code - Level B
65
Repair
66
Warranty
66
Advertisement
Advertisement
Related Products
Dynisco UPR800 Series
Dynisco UPR800-0-0-3
Dynisco UPR800-0-2-3
Dynisco UPR800-0-3-3
Dynisco UPR800-0-2-5
Dynisco UPR800-1-0-3
Dynisco UPR800-1-2-3
Dynisco UPR800-1-0-5
Dynisco UPR800-1-2-5
Dynisco UPR800-1-3-5
Dynisco Categories
Transmitter
Laboratory Equipment
Touch Panel
Controller
Test Equipment
More Dynisco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL