Controller
StorageWorks HSZ50
Digital Equipment StorageWorks HSZ50 Manuals
Manuals and User Guides for Digital Equipment StorageWorks HSZ50. We have
1
Digital Equipment StorageWorks HSZ50 manual available for free PDF download: Service Manual
Digital Equipment StorageWorks HSZ50 Service Manual (330 pages)
DIGITAL StorageWorks Array Controller
Brand:
Digital Equipment
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
5
Related Documents
13
1 Troubleshooting
15
Interpreting Controller LED Codes
15
Table 1-1 Solid Controller LED Codes
17
Table 1-2 Flashing Controller LED Codes
18
Troubleshooting HSZ50 Controllers
21
Troubleshooting When You Cannot Access Host Units
21
Troubleshooting on a DIGITAL UNIX System
22
Using the DIGITAL UNIX File Utility
23
Openvms Host Troubleshooting
24
Troubleshooting Application Errors
25
Locating a Device Error
25
Controller Generated Event
33
Command Timeout (Host System Timeout)
40
Locating a Host Bus Error
40
Select Timeout (SCSI Protocol Timeout)
44
Identifying Unit Attention Errors
47
Openvms Unit Attention
47
DIGITAL UNIX Unit Attention
51
Using FMU to Describe Event Log Codes
56
FMU Command Example
58
Using FMU to Describe Recent Last Fail or Memory System Failure Codes
58
FMU Output Example
59
Testing Disks (DILX)
60
Running a Quick Disk Test
60
Running an Initial Test on All Disks
61
Running a Disk Basic Function Test
63
Running an Advanced Disk Test
66
DILX Error Codes
69
DILX Data Patterns
70
Table 1-3 DILX Data Patterns
70
Monitoring System Performance with the VTDPY Utility
71
How to Run VTDPY
71
Using the VTDPY Control Keys
72
Using the VTDPY Command Line
72
Table 1-4 VTDPY Control Keys
72
Table 1-5 VTDPY Commands
73
How to Interpret the VTDPY Display Fields
74
SCSI Host Port Characteristics
74
Device SCSI Status
75
Unit Status (Abbreviated)
76
Unit Status (Full)
79
Device Status
82
Device SCSI Port Performance
85
Help Example
85
2 Replacing Field-Replaceable Units
87
Introduction and Precautions
87
Electrostatic Discharge
88
Handling Controllers or Cache Modules
88
Handling the Program Card
88
Handling Controller Host-Port Cables
89
Required Tools
89
Replacing Dual-Redundant Controllers and Cache Modules Using C_SWAP
89
Table 2-1 Required Tools
89
Figure 2-1 Connecting a Maintenance Terminal
90
Preparing the Subsystem
90
Figure 2-2 Disconnecting the Trilink Connector
92
Removing the Controller and Cache Modules
93
Figure 2-3 Removing the Program Card
94
Figure 2-4 Disconnecting the Battery Cable and Disabling the ECB
96
Figure 2-5 Removing Controllers and Cache Modules
97
Reinstalling the Controller Subsystem Components
98
Figure 2-6 Installing Controllers and Cache Modules
100
Restarting the Subsystem
102
Table 2-2 ECB Status Indicators
103
Replacing a Controller and Cache Module in a Single Controller Configuration
104
Removing the Controller and Cache Modules
104
Figure 2-7 Disabling the ECB
106
Reinstalling Controller Subsystem Components
107
Figure 2-8 Installing the Program Card
108
Replacing Dual-Redundant Controllers and Cache Modules
110
Using the Off-Line Method
110
Removing the Controller and Cache
110
Reinstalling Subsystem Components
111
Table 2-3 ECB Status Indicators
113
Replacing External Cache Batteries (Ecbs)
114
Replacing Ecbs Using the On-Line Method
114
Preparing the Subsystem
114
Replacing the Failed ECB
115
Reinstalling the Modules
117
Restarting the Subsystem
118
Preparing to Replace the Second ECB
119
Replacing the Second ECB
119
Reinstalling the Modules
121
Restarting the Subsystem
122
Replacing Ecbs Using the Off-Line Method
123
Table 2-4 ECB Status Indicators
124
Replacing Power Supplies
125
Cold-Swap
125
Removing the Power Supply
125
Figure 2-9 Removing the Power Supply
126
Installing the New Power Supply
126
Asynchronous Swap Method
127
Figure 2-10 Power Supply Fault Indicators
127
Replacing Storage Devices
128
Asynchronous Disk Drive Swap
128
Disk Drive Replacement Procedure (3.5, 5.25-Inch Drives)
128
Figure 2-11 Removing a Disk Drive
129
Replacing Tape Drives
130
Figure 2-12 Default Indicators for 3.5- and 5.25-Inch Sbbs
130
Tape Drive Replacement Procedure
130
Replacing Solid-State Disk and CD-ROM Drives
131
Figure 2-13 OCP LED Patterns
131
Solid-State Disk and CD-ROM Drive Replacement Procedure
131
Figure 2-14 Removing the CD-ROM Drive
132
Replacing SCSI Host Cables
133
Replacing the SCSI Host Cables
133
Figure 2-15 Disconnecting the SCSI Host Cable
134
Replacing SCSI Device Port Cables
135
Replacing the Device Port Cables
135
Figure 2-16 Removing the Volume Shield
136
Figure 2-17 Access to the SCSI Cables
137
3 Installing and Upgrading
139
Upgrading Array Controller Software
139
Program Card Upgrade (Single Controller Configuration)
141
Program Card Upgrade (Dual-Redundant Configuration)
142
Upgrading Controller Software Using the CLCP Utility
143
Invoking the CLCP Utility
143
Code Load Methods
143
Single Controller Upgrade Method
144
Host Port Upgrade
145
Figure 3-1 Single Controller Code Load Method
145
Figure 3-2 Host Port Code Load Operation
146
Host Download Script Requirements
146
Preparing the Software Image
146
Setting up the Host
147
Write Enable the Program Card in the Controller
147
Figure 3-3 Write Enable the Program Card
148
Running the CLCP Utility
148
Maintenance Terminal Port Upgrade
151
Figure 3-4 Terminal Port Code Load Operation
151
System Setup
152
Figure 3-5 Binary Transfer Protocol Selection
153
Write Enable the Program Card in the Controller
154
Running the CLCP Utility
154
The Dual-Redundant, Sequential Upgrade Method
157
Special Considerations for the Sequential Code Load Upgrade Method
157
Figure 3-6 the Sequential Upgrade Method
158
Sequential Upgrade Procedure
159
The Dual-Redundant Concurrent Code Load Upgrade Method
159
Considerations for the Concurrent Code Load Upgrade Method
160
Figure 3-7 the Concurrent Upgrade Method
161
Concurrent Code Load Upgrade Procedure
162
Patching Controller Software
163
Code Patch Considerations
164
Listing Patches
164
Installing a Patch
166
Code Patch Messages
168
Formatting Disk Drives
170
Considerations for Formatting Disk Drives
171
Installing New Firmware on a Device
173
Figure 3-8 Installing New Firmware on a Disk or Tape Drive
173
Considerations for Installing New Device Firmware
174
HSUTIL Abort Codes
175
HSUTIL Messages
175
Table 3-1 Abort Codes
175
Installing a Controller and Cache Module in a Single Controller Configuration
179
Table 3-2 SCSI ID Slots
179
Figure 3-9 Installing an SBB Battery Module
180
Figure 3-10 Installing Controller Power Supplies
180
Figure 3-11 Installing a Single Controller (SW800 Cabinet)
181
Table 3-3 ECB Status Indicators
182
Installing a Second Controller and Cache Module
183
Installing a Write-Back Cache Module
186
Removing the Controller
186
Installing the Write-Back Cache Module
187
Adding Cache Memory
188
Installing SIMM Cards
188
Table 3-4 Adding Cache Memory Capacity
189
Installing Power Supplies
191
Power Supply and Shelf LED Status Indicators
191
Table 3-5 Power Supply Status Indicators -- SW300 Cabinet
191
Table 3-6 Shelf and Single Power Supply Status Indicators
192
SW500, SW800 Cabinets
192
Table 3-7 Shelf and Dual Power Supply Status Indicators
193
SW500, SW800 Cabinets
193
Power Supply Installation Procedure
194
Figure 3-13 Installing a Power Supply
194
Installing Storage Building Blocks
195
SBB Activity and Fault Indicators
196
Table 3-8 Storage SBB Status Indicators
197
Installing Sbbs (Except Solid State Disk and CD-ROM)
198
Installing a Solid State Disk or CD-ROM
198
4 Moving Storagesets and Devices
201
Precautions for Retaining Data
202
Moving Storagesets
203
Figure 4-1 Moving a Storageset from One Subsystem to
203
Moving Storageset Members
206
Figure 4-2 Moving Storageset Members
206
Moving a Single Disk-Drive Unit
208
Moving a Tape Drive, CD-ROM Drive, or Tape Loader
209
5 Removing
211
Removing a Patch
211
Removing a Controller and Cache Module
211
Removing Storage Devices
211
Removing Disk Drives
216
Removing Solid State Disks and CD-ROM Drives
217
Figure 5-1 Removing a 3.5-Inch Disk Drive
217
Removing Tape Drives
218
Figure 5-2 OCP LED Patterns
218
Appendix A Instance, Codes and Definitions
220
Table A-1 Instance, Codes
220
Last Fail Codes
257
Table A-2 Executive Services Last Failure Codes
257
Table A-3 Value-Added Services Last Failure Codes
261
Table A-4 Device Services Last Failure Codes
271
Table A-5 Fault Manager Last Failure Codes
279
Table A-6 Common Library Last Failure Codes
282
Table A-7 DUART Services Last Failure Codes
282
Table A-8 Failover Control Last Failure Codes
283
Table A-9 Nonvolatile Parameter Memory Failover Control Last Failure Codes
284
Table A-10 Facility Lock Manager Last Failure Codes
286
Table A-11 Integrated Logging Facility Last Failure Codes
287
Table A-12 CLI Last Failure Codes
287
Table A-13 Host Interconnect Services Last Failure Codes
289
Table A-14 SCSI Host Interconnect Services Last Failure Codes
290
Table A-15 Host Interconnect Port Services Last Failure Codes
291
Table A-16 Disk and Tape MSCP Server Last Failure Codes
293
Table A-17 Diagnostics and Utilities Protocol Server Last Failure Codes
294
Table A-18 System Communication Services Directory Last Failure Code
295
Table A-19 SCSI Host Value-Added Services Last Failure Codes
295
Table A-20 Disk Inline Exerciser (DILX) Last Failure Codes
295
Table A-21 Tape Inline Exerciser (TILX) Last Failure Codes
296
Table A-22 Device Configuration Utilities (CONFIG/CFMENU) Last Failure Codes
298
Table A-23 Clone Unit Utility (CLONE) Last Failure Codes
299
Table A-24 Format and Device Code Load Utility (HSUTIL) Last Failure Codes
299
Table A-25 Code Load/Code Patch Utility (CLCP) Last Failure Codes
299
Table A-26 Induce Controller Crash Utility (CRASH) Last Failure Codes
300
Repair Action Codes
301
Table A-27 Repair Action Codes
301
Glossary
313
Index
325
Advertisement
Advertisement
Related Products
Digital Equipment HSZ40
Digital Equipment StorageWorks HSZ70
Digital Equipment HD4000
Digital Equipment H8508
Digital Equipment H8504P
Digital Equipment HA3000
Digital Equipment Prioris HX590 DP
Digital Equipment Prioris HX 6000
Digital Equipment H9642
Digital Equipment H9644
Digital Equipment Categories
Desktop
Server
Computer Hardware
Printer
Storage
More Digital Equipment Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL