User Manuals: Dettson AMP112SD Oil-Fired Furnace
Manuals and User Guides for Dettson AMP112SD Oil-Fired Furnace. We have
3
Dettson AMP112SD Oil-Fired Furnace manuals available for free PDF download: Installation Instructions And Homeowner's Manual, Homeowner's Manual
Dettson AMP112SD Installation Instructions And Homeowner's Manual (48 pages)
MULTIPOSITION OIL FIRED FURNACE
Brand:
Dettson
| Category:
Furnace
| Size: 2 MB
Table of Contents
English
2
Table of Contents
2
1 Safety Regulations
3
Safety Labeling and Warning Signs
3
Important Information
3
Detection Systems
3
Danger of Freezing
3
2 Installation
4
Positioning the Furnace
4
Configurations
4
Figure 1: Location and Dimensions of Ventilation Air
4
Openings in a Closet Door
4
Figure 2: Upflow Installation
4
Electrical System
5
Installation of the Thermostat
5
Figure 3: Downflow Installation
5
Figure 4: Horizontal Installation
5
Figure 5: Thermostat Wiring, Heating and Air Conditioning
5
2.5 Installation of the Burner
6
Venting
6
Figure 6: Thermostat Wiring, Heating and Air Conditioning
6
With ECM Variable Speed Motor
6
Conditioning/Heat Pump with ECM Variable Speed
6
Blocked Vent Shut-Off Device (Bvso) for Chimney Venting
7
Combustion Air Supply and Ventilation
7
Ducting
8
Supply Air Adjustments (4 Speed Motors)
8
Table 1: Blower Speed Adjustments, 4 Speed Motor
8
Supply Air Adjustments (Ecm Variable Speed Motors)
9
2.13 Installation of Accessories
9
Figure 8: Blower Start/Stop Delays, Board #1158
9
Table 2: Air Adjustments, Heating Mode
9
Table 3: Airflow Adjustments, Air Conditioning Mode
9
Table 4: Airflow Adjustments, All Modes
9
Table 5: Delay Adjustments, Heating Mode
9
3 Operation
10
Start-Up
10
Operating Sequence Oil Heating Mode
10
Checks and Adjustments
10
4 Maintenance
11
Cleaning the Heat Exchanger
11
Cleaning the Blocked Vent Shut-Off Device (Bvso)
12
Changing of the Burner Head
12
Changing the Nozzle
12
Changing the Oil Filter
12
Changing the Air Filter
12
5 Furnace Information
13
Motor
14
Table 6: Technical Specifications
14
Table 7: Airflow Data, with 1/2 HP, ECM Motors
15
Table 9: Min. Clearances from Combustible Material
16
Figure 9: Furnace Dimensions
17
Figure 10: Wiring Diagram 4 Speed Motor (PSC)
18
Figure 11: Wiring Diagram Variable Speed Motor (ECM)
19
Figure 12: Parts List with 4 Speed Motor (PSC)
20
Table 10: Parts List with 4 Speed Motor (PSC)
21
Figure 13: Parts List with Variable Speed Motor (ECM)
22
Table 11: Parts List with Variable Speed Motor (ECM)
23
Français
26
1 Règles de Sécurité
27
Signalisation Danger, Mise en Garde Et
27
Avertissement
27
Remarques Importantes
27
Systèmes de Protection
27
Risque de Gel
28
2 Installation
28
Emplacement
28
Configurations
29
Raccordement Électrique
30
Installation du Thermostat
30
Installation du Brûleur
31
Évacuation
31
Dispositif D'arrêt Anti-Refoulement (Bvso)
32
Évacuation Par Cheminée
32
Approvisionnement en Air de Combustion Et
32
Ventilation
33
Réservoir de Mazout
33
2.10 Système de Distribution D'air
33
Ajustement des Débits D'air de Ventilation
33
(Moteur 4 Vitesses)
33
Installation D'équipments Connexes
34
3 Opération
35
Mise en Marche
35
Séquence de Fonctionnement en Mode
35
Chauffage Au Mazout
35
Vérifications Et Ajustements
35
4 Entretien
37
Nettoyage de L'échangeur de Chaleur
37
Nettoyage du Dispositif D'arrêt Anti
37
Refoulement (Bvso)
37
Nettoyage de la Tête du Brûleur
38
Remplacement du Gicleur
38
Remplacement du Filtreà L'huile
38
Remplacement du Filtre À Air
38
5 Fiche Technique de L'appareil
38
Tableau 6: Spécifications Techniques
39
Tableau 7: Débit D'air Unités Avec Moteur 1/2 HP ECM.17
40
Tableau 8: Débit D'air Unités Avec Moteur 1/2 HP PSC
41
Advertisement
Dettson AMP112SD Installation Instructions And Homeowner's Manual (29 pages)
Multiposition High-Boy Oil-Fired Furnace
Brand:
Dettson
| Category:
Furnace
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Safety
5
Safety Labeling and Warning Signs
5
Important Information
5
Detection Systems
5
Danger of Freezing
6
2 Installation
6
Positioning the Furnace
6
Installation in an Enclosure
6
Configurations
7
Upflow Installation
7
Downflow Installation
7
Horizontal Installation
7
Electrical System
8
Installation of the Thermostat
8
Installation of the Burner
9
Nozzles
9
Air and Turbulator Settings
9
Post Purge Delay Adjustment
9
Venting
9
Masonry Chimney
9
Factory-Built Chimneys
10
Draft Regulator
10
Side Wall Venting
10
Blocked Vent Shut-Off Device (Bvso) for Chimney Venting
10
BVSO Functional Test
10
Combustion Air Supply and Ventilation
10
Contaminated Combustion Air
11
Burner with Outdoor Combustion Air Kit
11
Ducting
11
Air Filter
11
Supply Air Adjustments (4 Speed Motors)
11
Table 1: Blower Speed Adjustments, 4-Speed Motor
12
Supply Air Adjustments (Ecm Variable Speed Motors)
13
Installation of Accessories
13
Humidifier (HUM)
13
Electronic Air Cleaner (EAC)
13
Table 2: Airflow Adjustments Heating Mode
13
Table 3: Airflow Adjustments Air Conditioning Mode
13
Table 4: Airflow Adjustments Heating Mode
13
Table 5: Delay Adjustments Heating Mode
13
Air Conditioner (or Heat Pump)
14
Emergency Heating Mode - Variable Speed Motor (ECM)
14
3 Operation
14
Start-Up
14
Operating Sequence Oil Heating Mode
14
Checks and Adjustments
15
Purging the Oil Line
15
Pressure Adjustment
15
Combustion Check
15
Draft Regulator Adjustment
15
Overfire Pressure Test
15
Vent Temperature Test
15
Supply Air Temperature Rise Test
15
Limit Control Check
16
Restart after Burner Failure
16
4 Maintenance
16
Cleaning the Heat Exchanger
16
Cleaning the Blocked Vent Shut-Off Device (Bvso)
17
Cleaning the Burner Head
17
Replacing the Nozzle
17
Replacing the Oil Filter
17
Changing the Air Filter
17
5 Furnace Information
18
6 Technical Specifications
19
Table 6: Technical Specifications
19
Table 7: Airflow Data, Models with 1/2HP ECM Motor
21
Table 8: Airflow Data Model with 1/2 HP 4-Speed Motor (PSC)
22
Table 9: Minimum Clearances from Combustible Materials
22
Table 10: Parts List with 4-Speed Moto (PSC)
26
Table 11: Parts List with Variable Speed Motor (ECM)
28
Table 12: Accessoires
29
Dettson AMP112SD Homeowner's Manual (21 pages)
HIGH-BOY MULTIPOSITION OIL-FIRED FURNACE
Brand:
Dettson
| Category:
Furnace
| Size: 1 MB
Table of Contents
Table of Contents
2
Installation
4
Positioning the Furnace
4
Installation in an Enclosure
4
Configurations
4
Upflow Installation
4
Downflow Installation
4
Figure 1: Location and Dimensions of Ventilation Air Openings in a Closet Door
4
Figure 2: Upflow Installation
4
Horizontal Installation
5
Electrical System
5
Installation of the Thermostat
5
Figure 3: Downflow Installation
5
Figure 4: Horizontal Installation
5
Figure 5: Heating & Air Conditioning with 4-Speed Motor
5
Figure 6: Thermostat Wiring, Heating and Air Conditioning with ECM Variable Speed Motor
5
Installation of the Burner
6
Nozzles
6
Air and Turbulator Settings
6
Post Purge Delay Adjustment
6
Venting
6
Masonry Chimney
6
Factory-Built Chimneys
6
Draft Regulator
6
Side Wall Venting
6
Figure 7: Thermostat Wiring, Heating and Air Conditioning/Heat
6
Blocked Vent Shut-Off Device (Bvso) for Chimney Venting
7
BVSO Functional Test
7
Combustion Air Supply and Ventilation
7
Contaminated Combustion Air
7
Burner with Outdoor Combustion Air Kit
7
Oil Tank
7
Ducting
8
Air Filter
8
Supply Air Adjustments (4 Speed Motors)
8
Supply Air Adjustments (Ecm Variable Speed Motors)
8
Installation of Accessories
8
Humidifier (HUM)
8
Electronic Air Cleaner (EAC)
8
Figure 8: Blower Start/Stop Delays
8
Table 1: Blower Speed Adjustments, 4-Speed Motor
8
Air Conditioner (or Heat Pump)
9
Operation
9
Start-Up
9
Operating Sequence Oil Heating Mode
9
Table 2: Airflow Adjustments Heating Mode
9
Table 3: Airflow Adjustments Air Conditioning Mode
9
Table 4: Airflow Adjustments Heating Mode
9
Table 5: Delay Adjustments Heating Mode
9
Checks and Adjustments
10
Purging the Oil Line
10
Pressure Adjustment
10
Combustion Check
10
Draft Regulator Adjustment
10
Overfire Pressure Test
10
Vent Temperature Test
10
Supply Air Temperature Rise Test
10
Limit Control Check
10
Restart after Burner Failure
10
Emergency Heating Mode - Variable Speed Motor (Ecm)
11
Maintenance
11
Cleaning the Heat Exchanger
11
Cleaning the Blocked Vent Shut-Off Device (Bvso)
11
Cleaning the Burner Head
11
Replacing the Nozzle
11
Replacing the Oil Filter
11
Changing the Air Filter
11
Furnace Information
12
Technical Specifications
13
Table 6: Technical Specifications
13
Table 7: Airflow Data, Models with 1/2HP ECM Motor
14
Figure 9: Furnace Dimensions
15
Table 8: Airflow Data Model with 1/2 HP 4-Speed Motor (PSC)
15
Table 9: Minimum Clearances from Combustible Materials
15
Figure 10: Wiring Diagram 4-Speed Motor (PSC)
16
Figure 11: Wiring Diagram Variable Speed Motor (ECM)
17
Figure 12: Parts List with 4-Speed Motor (PSC)
18
Table 10: Parts List with 4-Speed Motor PSC
19
Figure 13: Parts List with Variable Speed Motor (ECM)
20
Table 11: Parts List with Variable Speed Motor (ECM)
21
Advertisement
Advertisement
Related Products
Dettson AMP105-IE2
Dettson AMP120-IE2
Dettson AMP154SD
Dettson AMP154SV
Dettson AMP105-IEV
Dettson AMP120-IEV
Dettson AMP112SV
Dettson AMP1-IE2
Dettson innovair AMP 112
Dettson innovair AMP 154
Dettson Categories
Furnace
Boiler
Air Conditioner
Thermostat
Air Handlers
More Dettson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL