CADD-Prizm PCS II 6101
Deltec CADD-Prizm PCS II 6101 Manuals
Manuals and User Guides for Deltec CADD-Prizm PCS II 6101. We have
1
Deltec CADD-Prizm PCS II 6101 manual available for free PDF download: Operator's Manual
Deltec CADD-Prizm PCS II 6101 Operator's Manual (152 pages)
Ambulatory infusion pump
Brand:
Deltec
| Category:
Medical Equipment
| Size: 0.72 MB
Table of Contents
Warnings
3
Cautions
7
Table of Contents
9
Section 1: General Description
15
Introduction
15
Indications
15
Epidural/Subarachnoid Administration
15
Analgesics
15
Anesthetics
15
Symbols
17
Pump Diagram
18
Description of the Keys, Display and Features
19
Indicator Lights
19
Display with Backlighting
19
Keypad
19
Power Jack
20
Data In/Out Jack
20
Air Detector Port Cover
20
Air Detector Accessory (Optional)
20
Cassette
21
Polemount Bracket Recess
21
Battery Compartment
21
Cassette Latch
21
Cassette / Keypad Lock
22
Other Features Not Shown
22
The Main Screen
23
Lock Levels
24
Autolock
24
Security Codes
24
Customizing the Security Codes
24
Lock Level Tables
25
Section 2: Pump Setup and Programming
27
Installing the Battery
27
To Install a Battery
28
Power up
29
If Biomed Toolbox Is Set to Clear Records and Lockouts in Power up
29
If Biomed Toolbox Is Set to Clear Program in Power up
30
Unlocking the Pump Program to LL0
32
To Unlock the Pump Program Using the Cassette / Keypad Lock Key
32
To Unlock the Pump Using the Keypad
32
Programming the Pump: General Instructions
33
Messages You May See During Programming
34
Before Beginning Programming
34
REPORTS Key
35
Dose Counters
35
Given
36
Doses Hour by Hour
36
Patient Review
37
Pain Scale
37
Pain Scale Log
38
Delivery Log
38
Event Log
39
New Patient Marker
39
If Biomed Toolbox Is Set to Clear Records and Lockouts in Reports Menu
39
In Reports Menu
40
Delivery Methods
42
Programming Screens
43
Units (if Applicable)
44
Concentration
44
Continuous Rate
44
Demand Dose
45
Demand Dose Lockout
45
Max Doses Per Hour
45
Set Delivery Limit
45
Reservoir Volume
46
Air Detector Status
46
Programming Example
47
Removing a Cassette
52
Attaching a Cassette
53
To Attach the Cassette to the Pump
53
Priming the Tubing and Connecting to the Patient
56
Inserting the Tubing into the Air Detector
58
Locking the Pump Program for the Patient
59
To Change the Lock Level When Autolock Is Not in Use
59
Remote Dose Cord
61
To Attach the Remote Dose Cord
61
To Detach the Remote Dose Cord
61
Starting the Pump
62
Adjusting Patient Delivery (Titration)
63
Titrating While the Pump Is Running
63
Section 3: Operating the Pump
65
Stopping the Pump
65
To Stop the Pump
65
To Turn Pump Indicators off
65
Starting the Pump
65
To Start the Pump
66
To Turn Pump Indicators off
66
Starting a Clinician Bolus
67
To Start a Clinician Bolus
67
Starting a Demand Dose
69
To Start a Demand Dose
69
Stopping a Demand Dose or Clinician Bolus
71
To Stop a Dose While the Pump Is Running
71
Resetting the Reservoir Volume
72
Resetting Reservoir Volume Without Changing the Cassette
72
Section 4: Options
73
Overview: Accessing Options
73
To Access Options
73
Lock Level
74
To Change Lock Level
74
Epidural Mode
75
To Turn Epidural Mode on or off
76
Programming Units
76
To Change Units
76
Time
77
To Change the Time of Day
77
Date
78
To Change the Date
78
Air Detector On/Off
79
To Change the Air Detector Setting
80
Section 5: Biomed Toolbox
81
Overview: Accessing the Biomed Toolbox
81
To Access the Biomed Toolbox Menu
81
Custom Concentrations
82
Dosing Limits
83
Delivery Limit
84
Program Limits
84
Maximum Delivery Rate
85
Key Beeps
86
Res Vol Trip Point
86
Res Vol Empty Alarm
87
Pump Stopped Alarm
87
Titration Limit
88
Autolock
89
PM (Preventive Maintenance) Reminder
90
Custom Lock Level Code
90
Custom Clinician Code
91
Units Selection
92
Units Location
92
Programming Units
93
Date Format
94
Custom Main Display
94
Auto Review
95
Custom Reports
95
To Access the Custom Reports Screens
96
Dose Counters
96
Given
96
Doses Hour by Hour
96
Patient Review
96
Pain Scale
97
Pain Scale Log
97
Delivery Log
97
Event Log
97
New Patient Marker
98
New Patient Marker Function
98
To View or Change the New Patient Marker Function
100
Upstream Sensor On/Off
101
Air Detector Requirement
102
Section 6: Reference & Troubleshooting
103
Troubleshooting
103
Alarms and Messages, Alphabetical List
105
Cleaning the Pump and Accessories
113
Cleaning the Battery Contacts
114
Exposure to Radiation or Magnetic Resonance Imaging (MRI)
115
Continuous Rate Scroll Ranges
116
Demand Dose, Clinician Bolus Scroll Ranges: Milliliters
116
Demand Dose, Clinician Bolus Scroll Ranges: Milligrams
117
Demand Dose, Clinician Bolus Scroll Ranges: Micrograms
118
Military Time Conversion Chart
119
Technical Description
120
Standards Used in Development of the Pump
120
Specifications (Nominal)
120
General Pump Specifications
120
Delivery Specifications
123
Options Specifications
124
Biomed Toolbox Specifications
124
Printed Reports
126
Screen Maps
127
Accuracy Test Results
129
Safety Features and Fault Detection
131
Data Handling and Software Safety Features
131
Inspection Procedures
134
Testing Procedures
135
Occlusion Pressure Range Tests
141
Accuracy Tests
144
Index
148
Limited Warranty
151
Advertisement
Advertisement
Related Products
Deltec CADD-Prizm PCSII 6101
Deltec 1700
Deltec CADD-Legacy PCA 6300
Deltec CADD-Prizm VIP CONTIN 6100
Deltec CADD-Prizm VIP CONTIN 6101
Deltec CADD-Prizm VIP PCA 6100
Deltec CADD-Prizm VIP PCA 6101
Deltec CADD-TPN 5700
Deltec Cozmo
Deltec Cozmo 1700
Deltec Categories
Aquariums
Water Filtration Systems
Medical Equipment
Swimming Pool Filter
Laboratory Equipment
More Deltec Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL