Sign In
Upload
Manuals
Brands
CoreTigo Manuals
Conference System
MCM Series
CoreTigo MCM Series Manuals
Manuals and User Guides for CoreTigo MCM Series. We have
1
CoreTigo MCM Series manual available for free PDF download: User Manual
CoreTigo MCM Series User Manual (130 pages)
EtherNet/IP
Brand:
CoreTigo
| Category:
Conference System
| Size: 4 MB
Table of Contents
Table of Contents
2
1 Introduction
9
About this User Manual
9
Manual Structure
9
Typographical Conventions
9
Symbols
9
Deviating Views
9
2 Safety and Requirements
10
General Note
10
Intended Use
10
Personnel Qualification
10
Power Drop for Write/Delete Access in File System
10
Exceeding the Maximum Number of Permitted Write/Delete Access
10
Information and Data Security
11
Regulatory Notices
11
Class a Warnings - Industrial Use
11
FCC Warning
11
ISED Warning
11
Interference Statement
11
Wireless Notice
12
Requirements
12
Hardware and System Requirements
12
Software
12
3 Getting Started
13
Product Description
13
Product Overview
13
Functionality
13
Figure 1: Tigomaster 2TH (Ethernet/Ip Version)
13
Table 1: Tigomaster 2TH Functionality (Ethernet/Ip Version)
14
Lasering
15
Revisions and Versions
15
Table 2: Tigomaster 2TH Hardware
15
Table 3: Tigomaster 2TH Software
15
Table 4: Tigomaster 2TH Firmware
15
Identification
16
LED Indications
16
Figure 2: Tigomaster 2TH Identification Code
16
Table 5: System Leds
16
Table 6: System LED States
17
Table 7: APL Leds
17
Table 8: Supply Voltage Leds
17
Table 9: Ethernet/Ip Adapter Leds
17
Table 10: Ethernet/Ip Adapter LED States
19
Table 11: Ethernet Status
19
Table 12: Ethernet LED States
20
Table 13: Wireless Track Status WT1
20
Table 14: Wireless Track Status WP01
20
Connection Points
21
Table 15: Power Supply Connectors
21
Table 16: Ethernet Connectors
21
Figure 3: Derating Tigomaster 2TH IO-Link Wireless Master
22
Table 17: SMA Antenna
22
4 Installation
23
Installing Hardware
23
Select the Mounting Location
23
Equipment Required
24
Mount the Tigomaster 2TH
24
Ground the Tigomaster 2TH
24
Demount the Tigomaster 2TH
25
Connection
25
Figure 4: Connection Example with Tigobridge
26
5 Configuration
27
Introduction
27
Ethernet/Ip Scanner
28
Table 18: Configuration Tools
28
Figure 5: EDS File Installation (1)
29
Figure 6: EDS File Installation (2)
29
Figure 7: Add New Module (1)
30
Figure 8: Add New Module (2)
30
Figure 9: Configure Module (1)
31
Figure 10: Configure Module (2)
31
Figure 11: Configure Module (3)
32
Figure 12: Setting Rpis
32
Figure 13: Wireless Port Configuration (1)
32
Figure 14: Wireless Port Configuration (2)
33
Table 19: Port Configuration
33
Tigoengine
34
Masters View
35
Connecting a New Master
35
Figure 15: Connect New Master Button
35
Figure 16: Connect New Master
36
Figure 17: Masters View - One Tigomaster 2TH Connected
36
Coretigo Web Server
37
Prerequisites
37
Functional Overview
37
Table 20: Functional Overview of the Coretigo Wireless Web Server for IO-Link Devices
37
Open the Coretigo Web Server
38
Licenses
39
Figure 18: Coretigo Web Server Dashboard
39
Table 21: Dashboard Information
39
IO-Link Wireless Master Settings
40
Channel Selection
40
Figure 19: Channel Selection Tab
40
Expert Settings
41
Table 22: WLAN Channels
41
W-Master Configuration
42
Figure 20: Expert Settings
42
Figure 21: Configuration Tab
42
Error Handling
43
Table 23: W-Master Advanced Configuration View
43
Scan and Pair
44
Figure 22: Scan Tab
44
Figure 23: Scan Result
45
Table 24: Scan Result/Pairing
45
Figure 24: Pairing Successful
46
Figure 25: Unpairing Successful
46
Device or Port Information
47
Device Information
47
Figure 26: Information Tab
47
Table 25: Information, Status, Settings, ISDU, Process Data
47
Figure 27: Information Tab - Device Information
48
Table 26: Information Tab Parameters
48
Port Status
49
Figure 28: Port Status Tab
49
Table 27: Port Status Parameters
49
Table 28: Possible Values for the Port State
50
Device ISDU
51
Figure 29: Display of on Request Data, Read/Write IO-Link Device Parameters
51
Figure 30: History List
52
Master ISDU
54
Figure 31: Display of the ISDU, Read/Write IO-Link Wireless Master Parameters
54
Process Data
56
Figure 32: Display of the Process Data
56
Table 29: Process Data Parameters
56
Device Settings
57
Figure 33: Settings Tab
57
Figure 34: Device Configuration Subtab
57
Figure 35: User Administration
58
Figure 36: Settings Tab, Port Cycle Subtab
58
Port Settings
58
Table 30: Settings in Port Configuration for IO-Link Device, Port Cycle Subtab
59
Table 31: Calculation of the Port Cycle Time of the IO-Link Wireless Master
59
Figure 37: Settings Tab, Validation Level Subtab
60
Table 32: Settings in Port Configuration for IO-Link Device, Validation Level Subtab
60
Table 33: Validation and Backup, Possible Values
60
Figure 38: Settings Tab, Transmission Subtab
61
Table 34: Settings in Port Configuration for IO-Link Device, Transmission Subtab
61
Figure 39: Settings Tab, Miscellaneous Subtab
62
Table 35: Settings in Port Configuration for IO-Link Device, Miscellaneous Subtab
62
Figure 40: Device Configuration Tab
64
Figure 41: Maintenance Information Tab
64
IP Parameters
64
Maintenance Information
64
Table 36: Maintenance Information Tab Parameters
65
Figure 42: Firmware Update Tab
66
Firmware Update
66
Master Reset
67
Factory Settings
68
Figure 43: Factory Reset Tab
68
MQTT Configuration
68
Table 37: Options to Delete Settings
68
Figure 44: MQTT Tab
69
Figure 45: MQTT Tab, Client Status, Client Configuration Subtab
69
Table 38: MQTT in Port Configuration for IO-Link Device, Client Status
70
Table 39: MQTT in Port Configuration for IO-Link Device, Client Configuration
70
Figure 46: MQTT Tab, Connection 1 > IP Settings Subtab
71
Table 40: MQTT in Port Configuration for IO-Link Device, Connection1 > IP Settings
71
Figure 47: MQTT Tab, Connection1 > Session Settings Subtab
72
Table 41: MQTT in Port Configuration for IO-Link Device, Connection1 > Session Settings
72
Figure 48: MQTT Tab, Connection1 > will Settings Subtab
73
Table 42: MQTT in Port Configuration for IO-Link Device, Connection1 > will Settings
74
Figure 49: MQTT Tab, Connection1 > Advanced Settings Subtab
75
Table 43: MQTT in Port Configuration for IO-Link Device, Connection1 > Advanced Settings
75
Figure 50: Menu Item Sign in - Input Mask for Username and Password
76
Log in and User Administration
76
Figure 51: Menu Item Sign out
77
Figure 52: User Administration Screen
78
Figure 53: Remove a User
78
6 Commissioning
79
Set the IP Address Via the Coretigo Web Server
79
Figure 54: Tigomaster 2TH Web Server
79
Figure 55: Sign in
80
Figure 56: Device Configuration Tab
80
Figure 57: Add Relation
81
Figure 58: New Entry Dialog Box
81
Configuration with the Coretigo Web Server
82
Requirements
82
Configure the IO-Link Wireless Master
82
Figure 59: Disable BOOTP/DHCP
82
Figure 60: Master > Configuration Tab
83
Scan
84
Figure 61: Scan Tab
84
Table 44: Configuration, Possible Values for IO-Link Wireless Master
84
Figure 62: Scan Tab with Result
85
Table 45: Scan Results
85
Use an OPC UA Client
86
Requirements
86
Instructions
86
Figure 63: Add Server Dialog Box (Discovery Tab)
86
Set the Device Date and Time Using OPC UA
87
Figure 64: Add Server Dialog Box > Advanced Tab)
87
Figure 65: Path to Ntpclientupdateconfiguration
88
Figure 66: Right-Clicking Ntpclientupdateconfiguration
89
Figure 67: Call Ntpclientupdateconfiguration Dialog Box-Before Call
89
Figure 68: Call Ntpclientupdateconfiguration Dialog Box-After Call
89
7 Process Data Mapping
90
Table 46: Connections 1-10 Overview
90
Connections
91
Table 47: Connections 1-4 Detail
91
Connections
94
Table 48: Connections 5-7 Detail
94
Table 49: Connections 8-10 Detail
99
8 OPC UA Server Connection
104
Tigomaster 2TH Identification
104
Figure 69: Path to Tigomaster 2TH Identification Nodes
104
Sensor/Actuator Identification
105
NTP Client Configuration
105
Table 50: Device Identification Nodes
105
Table 51: Sensor/Actuator Identification Nodes
105
Convert an IP Address to a Decimal Number
107
Table 52: OPC UA Server Nodes for Configuring NTP Client
107
Wireless Connection
108
Table 53: Track and Slot (Double-Slot)
108
Table 54: Track and Slot (Single-Slot)
108
9 Status and Diagnosis
109
Tigomaster 2TH
109
Ethernet/Ip
109
Table 55: Class Attributes Event Log Object 65 (0X41)
109
Table 56: Mapping CIP Instances to IO-Link Ports
109
Table 57: Instance Attributes Event Log Object 65 (0X41)
110
Table 58: Log Entry Structure
112
Table 59: Services Event Log Object 65 (0X41)
112
IO-Link Diagnosis
113
Event Qualifier
113
Figure 70: Event Qualifier
113
Table 60: Event Qualifier
113
IO-Link Wireless Master Event Codes
114
IO-Link Device Event Codes (Common)
114
Table 61: Master Event Codes
114
Table 62: IO-Link Device Event Codes
114
10 Technical Data
117
Product Specifications
117
Table 63: Product Specifications
117
Table 64: SMA Antenna Specifications
120
Ethernet/Ip Specifications
121
Table 65: Protocol Specifications
121
OPC UA Server
123
Table 66: OPC UA Server Technical Data
123
Dimensions
124
Figure 71: Dimensions
124
Appendix A - Part Number
125
Table 67: Ethernet/Ip Version
125
Appendix B - Evaluation Agreement
126
Advertisement
Advertisement
Related Products
CoreTigo MCM-EI-00-00-A
CoreTigo Categories
Network Hardware
Switch
Conference System
Gateway
Controller
More CoreTigo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL