Sign In
Upload
Manuals
Brands
ComAp Manuals
Other
MainsPro
ComAp MainsPro Manuals
Manuals and User Guides for ComAp MainsPro. We have
2
ComAp MainsPro manuals available for free PDF download: Global Manual, Installation And Operation Manual
ComAp MainsPro Global Manual (68 pages)
Mains Decoupling Protection Relay
Brand:
ComAp
| Category:
Relays
| Size: 3 MB
Table of Contents
Table of Contents
2
1 Document Information
6
Clarification of Notation
6
About this Guide
6
Installation and Operation Guide
6
Application Guide
6
Reference Guide
6
Legal Notice
6
Document History
8
2 Introduction of Installation and Operation Guide
9
Purpose of this Manual
9
Confornity Declaration
9
Warnings
10
Dangerous Voltage
10
Adjust the Setpoints
10
3 Installation Data
11
Dimensions
11
List of Terminals
12
Mainspro Frame
12
Wiring
12
Star" Connection
13
Delta" Connection
13
Connection with Voltage Transformers
14
Single-Phase Connection
14
Power Supply
15
Relay Outputs Connection
16
Binary Switches Connection
16
Measurement Range
16
Wiring Examples
17
4 User Interface
19
Front Panel Elements
19
Back to Table of Contents
19
Pushbuttons
20
Setpoints Change
20
Reset Operation Time
21
Reset Trip Counters
21
TEST Mode Activation
21
Factory Default
22
Mechanical Sealing
22
Signalization Leds
22
Measurement Screens
24
Alarm Messages
26
5 Introduction of Application Guide
28
Purpose of this Manual
28
Mainspro Typical Usage
28
Typical Applications of Mainspro Protection Relay
28
6 Important Steps of Mainspro Utilization
30
7 TRIP and Fault Reset
31
Trip
31
TRIP Event
31
TRIP Status
31
Fault Reset
32
8 Protective Features
33
ANSI 59 Overvoltage, ANSI 27 Undervoltage
33
Floating 10 Minutes Average Overvoltage
34
ANSI 81H Overfrequency, 81L Underfrequency
34
ANSI 47 Voltage Unbalance and Angle Asymmetry
36
Voltage Unbalance
36
Positive Sequence Undervoltage, Negative Sequence Overvoltage
36
ANSI 78 Vector Shift
37
Measuring Principle
38
Rate of Change of Frequency (ROCOF)
39
Phase Rotation, Incorrect Phase Polarity
39
9 Application Tips
40
Automatic Return to Mains
40
Binary Switches
40
Back to Table of Contents
40
Alternative Settings
41
CB Feedback
41
Disable
41
External Trip
41
Fault Reset
41
Counters
41
Timer
42
Start Trip
42
TEST Mode
42
10 Introduction of Reference Guide
44
Purpose of this Manual
44
11 Technical Data
45
Accuracies and Reaction Times
45
Operating Area
45
Voltage Measurement
46
Frequency Measurement
46
Time Delays Accuracy
46
Loss of Mains Reaction Times
46
Technical Parameters
46
Endurance to the Power Supply Voltage Fails
47
Factory Default Setting of Mainspro Unit
47
12 Appendix
50
Library of Setpoints
51
Group: Basic
52
Uin
52
System
52
Dispt [Min]
52
Auto FR
52
Auto FR del [S]
53
Start Trip
53
Imp Len [S]
53
Bak Trp del [S]
53
Ext
54
F.r
54
Alt
54
Disable
54
Group: V <>, a
55
V>, V>>, V<, V<<, A.V>, A.V>>, A.V<, A.V<< [V]
55
V> Del, V>> Del, V< Del, V<< del [S]
55
Avg V> [V]
55
Group: Du, A.du
56
Rstv>,V>> [%V>]
56
Unb, A.V Unb [V]
56
V< Pos, A.V< Pos [V]
56
Group: F <>, A.f
57
V> Neg, A.V> Neg [V]
57
Du Del, A.du del [S]
57
F>, F>>, F<, F<<, A.f>, A.f>>, A.f<, A.f<< [Hz]
57
F> Del, F>> Del, F< Del, F<< Del, A.f> Del, A.f>> Del, A.f< Del, A.f<< del [S]
57
Group: LOM, A.LOM
58
Rstf>,F>> [%F>]
58
VS Lim, A.VS Lim [°]
58
ROCOF, A.ROCOF [Hz/S]
58
Group: F(BI)
59
ROCOF Filt, A.ROCOF Filt
59
LOM Init Del, A. LOM Init del [S]
59
LOM Trp Del, A.LOM Trp del [S]
59
ROCOF Del/A.rocof del [S]
59
Group: F(RE)
60
F(Re1-5)
60
Library of Binary Switches
61
Ext Trip
61
Fault Reset
61
Alt Settings
61
Disable
61
CB Feedback
61
Back to Appendix
61
Relay Outputs
62
Commtrpper
63
Commtrpimp
63
Commsigimp
63
Commsigimp
64
Commsigdel
64
U Sig
64
Sig
65
LOM Sig
65
Du Sig
65
Du Sig
66
Other Sig
66
Alt Sig
66
Trpendimp
66
Trpendimp
67
Internfail
67
Baktrpper
67
Baktrpimp
68
Back to Appendix
68
Advertisement
ComAp MainsPro Installation And Operation Manual (53 pages)
Mains Decoupling Protection Relay
Brand:
ComAp
| Category:
Other
| Size: 1 MB
Table of Contents
Table of Contents
4
Application Guide
2
Reference Guide
2
Table of Contents
4
Introduction
5
Purpose of this Manual
5
Conformity Declaration
5
Warnings
6
Installation Data
7
Dimensions
7
List of Terminals
8
Mainspro Frame
8
Wiring
9
Star" Connection
9
Delta" Connection
9
Connection with Voltage Transformers
10
Single-Phase Connection
10
Power Supply
10
Relay Outputs Connection
11
Binary Switches Connection
12
Measurement Range
12
Wiring Examples
12
User Interface
15
Control and Navigation Pushbuttons - Basic Operation
15
Setpoints Change
15
Reset Operation Time
16
Reset Trip Counters
16
TEST Mode Activation
17
Factory Default
17
Mechanical Sealing
17
Signalization Leds
17
Measurement Screens
19
Alarm Messages
21
Table of Contents
23
Mainspro Typical Usage
24
Typical Applications of Mainspro Protection Relay
24
Purpose of this Manual
24
Important Steps of Mainspro Utilization
25
TRIP and Fault Reset Description
26
Trip
26
Fault Reset
26
Protective Features
27
Floating 10 Minutes Average Overvoltage
27
Overfrequency, 81L Underfrequency
27
Voltage Unbalance and Angle Asymmetry
27
Vector Shift
28
Rate of Change of Frequency (ROCOF)
30
Phase Rotation, Incorrect Phase Polarity
30
Application Tips
30
Automatic Return to Mains
30
Binary Switches Application
30
Counters
31
Timer
31
Start Trip
31
TEST Mode
32
Table of Contents
34
Purpose of this Manual
36
Library of Setpoints
37
Basic
37
Uin
37
System
37
Dispt [Min]
37
Auto FR
37
Auto FR del [S]
37
Start Trip
37
Imp Len [S]
38
Bak Trp del [S]
38
Ext
38
Alt
38
Disable
38
V>, V>>, V<, V<<, A.V>, A.V>>, A.V<, A.V<< [V]
38
V> Del, V>> Del, V< Del, V<< del [S]
39
Rstv>,V>> [%V>]
39
Du, A.du
39
Unb, A.V Unb [V]
39
V< Pos, A.V< Pos [V]
39
V> Neg, A.V> Neg [V]
40
Du Del, A.du del [S]
40
F <>, A.f
40
F>, F>>, F<, F<<, A.f>, A.f>>, A.f<, A.f<< [Hz]
40
F> Del, F>> Del, F< Del, F<< Del, A.f> Del, A.f>> Del, A.f< Del, A.f<< del [S]
40
Rstf>,F>> [%F>]
40
Lom, A.lom
41
VS Lim, A.VS Lim [°]
41
ROCOF, A.ROCOF [Hz/S]
41
ROCOF Filt, A.ROCOF Filt
41
LOM Init Del, A. LOM Init del [S]
41
LOM Trip Del, A.LOM Trip del [S]
41
F(Re)
42
F(Re1-5)
42
Library of Binary Switches
43
Ext Trip
43
Fault Reset
43
Alt Settings
43
Disable
43
CB Feedback
43
Library of Relay Outputs
44
Commtrpper
44
Commtrpimp
44
Commsigimp
44
Commsigimp
45
Commsigdel
45
U Sig
45
Sig
45
LOM Sig
46
Du Sig
46
Other Sig
46
Trpendimp
46
Internfail
47
Baktrpper
47
Baktrpimp
47
Technical Data
49
Accuracies and Reaction Times
49
Operating Area
49
Voltage Measurement
50
Frequency Measurement
50
Time Delays Accuracy
50
Loss of Mains Reaction Times
50
Technical Parameters
51
Endurance to the Power Supply Voltage Fails
51
Statement of the Factory Default Setting of Mainspro Unit
52
Advertisement
Related Products
ComAp InteliLite MRS10
ComAp InteliLite MRS11
ComAp InteliLite MRS15
ComAp InteliLite MRS16
ComAp InteliNano MRS 3
ComAp Categories
Controller
Control Unit
Monitor
Relays
Water Filtration Systems
More ComAp Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL