Circutor RECmax-CVM 4-pole Manuals
Manuals and User Guides for Circutor RECmax-CVM 4-pole. We have
2
Circutor RECmax-CVM 4-pole manuals available for free PDF download: Instruction Manual
Circutor RECmax-CVM 4-pole Instruction Manual (68 pages)
Brand:
Circutor
| Category:
Circuit breakers
| Size: 7 MB
Table of Contents
Safety Precautions
3
Disclaimer
3
Table of Contents
4
Contents
4
Revision Log
6
Symbols
6
1�- Verifications Upon Reception
7
2�- Description of the Product
7
3�- Installing the Device
9
3�1�- Preliminary Recommendations
9
3�2�- Installation
10
3�2�1�- Measurement of the Earth Leakage Current
10
3�2�2�- Measurement of the Phase Current
11
3�2�3�- Safety Seal
11
3�3�- Terminals of the Device
12
3�4�- Connection Diagrams
14
3�4�1�- MEASUREMENT of SINGLE-PHASE NETWORK: Recmax-CVM 2-POLE
14
3�4�2�- MEASUREMENT of THREE-PHASE NETWORK: Recmax-CVM 4-POLE
15
3�5�- Disconnection of the Device
16
4�- Operation
17
4�1�- Operating Principle
17
4�2�- Description of the Device
18
4�3�- Keyboard Functions
19
4�4�- Display
20
4�5�- Led Indicators
21
4�6�- Inputs
22
4�7�- Outputs
22
4�8�- Reset Lever and Manual Locking
23
4�9�- Normal Operating Status
23
4�10�- Trip Status
24
4�10�1�- Automatic Reclosing Is Possible
24
4�10�2�- Automatic Reclosing Is Not Possible
25
5�- Display
27
5�1�- Normal Operating Status
27
5�1�1�- Electrical Parameters Display Screens
29
5�1�2�- Communications Settings Parameters Display Screens
34
5�2�- Trip Status
35
5�2�1�- Earth Leakage Protection Trip
35
5�2�2�- Circuit Breaker Trip
36
5�2�3�- Tripping with the Test Key
36
5�2�4�- Trip Due to Ext On/Off Input
37
6�- Configuration
38
6�1�- Earth Leakage Protection
38
6�1�1�- Activation Delay
38
6�1�2�- Sensitivity Current, Iδn
39
6�2�- Automatic Reclosing
40
6�2�1�- Srd: Earth Leakage Reclosing Sequence
40
6�2�2�- Srm: Circuit Breaker Reclosing Sequence
41
6�2�3�- Rstc: Partial Meter Resetting
42
6�2�4�- Polt: Configuration of Rec Locked Output
42
6�2�5�- Freq: Nominal Frequency
43
6�2�6�- Fact: Factory Configuration
44
6�3�- Rs-485 Communications: Peripheral Number
44
6�4�- Locking the Configuration
45
6�4�1�- Physical Locking
45
6�4�2�- Program Locking
45
7�- Rs-485 Communications
46
7�1�- Connections
46
7�2�- Modbus Protocol
47
7�2�1� READ EXAMPLE: Function 0X04
47
7�2�2� WRITE EXAMPLE: Function 0X05
47
7�3�- Modbus Commands
48
7�3�1� Measurement Variables
48
7�3�2� Energy Variables
49
7�3�3� Voltage and Current Harmonics
50
7�3�4� Protection Variables
51
7�3�5� Deleting Parameters
52
7�3�6� Function of the Positive Safe Output Relay
52
7�3�7� Status of the Inputs
52
7�3�8� Status of the Relay Outputs
53
7�3�9� Digital Output Status
53
7�3�10� Power Status
53
7�3�11� Measurement Alarms
54
7�3�12� Device Information
54
7�3�13� Device Configuration Variables
54
8�- Technical Features
60
9�- Technical Service
64
10�- Warranty
64
11�- Ce Certificate
65
Advertisement
Circutor RECmax-CVM 4-pole Instruction Manual (62 pages)
Earth leakage circuit breaker with automatic reclosing and measurement system
Brand:
Circutor
| Category:
Circuit breakers
| Size: 2 MB
Table of Contents
Safety Precautions
3
Disclaimer
3
Table of Contents
4
Contents
4
Revision Log
6
Symbols
6
1�- Verifications Upon Reception
7
2�- Description of the Product
7
3�- Installing the Device
9
3�1�- Preliminary Recommendations
9
3�2�- Installation
10
3�2�1�- Measurement of the Earth Leakage Current
10
3�2�2�- Measurement of the Phase Current
11
3�2�3�- Safety Seal
11
3�3�- Terminals of the Device
12
3�4�- Connection Diagrams
14
3�4�1�- MEASUREMENT of SINGLE-PHASE NETWORK: Recmax-CVM 2-POLE
14
3�4�2�- MEASUREMENT of THREE-PHASE NETWORK: Recmax-CVM 4-POLE
15
3�5�- Disconnection of the Device
16
4�- Operation
17
4�1�- Operating Principle
17
4�2�- Description of the Device
18
4�3�- Keyboard Functions
19
4�4�- Display
20
4�5�- Led Indicators
21
4�6�- Inputs
22
4�7�- Outputs
22
4�8�- Reset Lever and Manual Locking
23
4�9�- Normal Operating Status
23
4�10�- Trip Status
24
4�10�1�- Automatic Reclosing Is Possible
24
4�10�2�- Automatic Reclosing Is Not Possible
25
5�- Display
27
5�1�- Normal Operating Status
27
5�1�1�- Voltage
28
5�1�2�- Current
29
5�1�3�- Power
29
Cos
30
5�2�- Trip Status
30
5�2�1�- Earth Leakage Protection Trip
30
5�2�2�- Circuit Breaker Trip
31
5�2�3�- Tripping with the Test Key
32
5�2�4�- Trip Due to Ext On/Off Input
32
6�- Configuration
33
6�1�- Earth Leakage Protection
33
6�1�1�- Activation Delay
33
6�1�2�- Sensitivity Current, Iδn
34
6�2�- Automatic Reclosing
35
6�2�1�- Srd: Earth Leakage Reclosing Sequence
35
6�2�2�- Srm: Circuit Breaker Reclosing Sequence
36
6�2�3�- Rstc: Partial Meter Resetting
37
6�2�4�- Polt: Configuration of Rec Locked Output
37
6�2�5�- Freq: Nominal Frequency
38
6�2�6�- Fact: Factory Configuration
39
6�3�- Locking the Configuration
39
6�3�1�- Physical Locking
39
6�3�2�- Program Locking
39
7�- Rs-485 Communications
41
7�1�- Connections
41
7�2�- Modbus Protocol
42
7�2�1� READ EXAMPLE: Function 0X04
42
7�2�2� WRITE EXAMPLE: Function 0X05
42
7�3�- Modbus Commands
43
7�3�1� Measurement Variables
43
7�3�2� Energy Variables
44
7�3�3� Voltage and Current Harmonics
45
7�3�4� Protection Variables
46
7�3�5� Deleting Parameters
47
7�3�6� Function of the Positive Save Output Relay
47
7�3�7� Status of the Inputs
47
7�3�8� Status of the Relay Outputs
48
7�3�9� Digital Output Status
48
7�3�10� Device Information
48
7�3�11� Device Configuration Variables
48
8�- Technical Features
54
9�- Technical Service
58
10�- Warranty
58
11�- Ce Certificate
59
Advertisement
Related Products
Circutor RECmax-CVM series
Circutor RECmax-CVM 2-pole
Circutor TRIO 480V
Circutor Compact DC-S 4I
Circutor Categories
Measuring Instruments
Relays
Battery Charger
Automobile Accessories
Controller
More Circutor Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL