Manuals and User Guides for CaridianBCT Spectra Optia. We have
1
CaridianBCT Spectra Optia manual available for free PDF download: Service Manual
CaridianBCT Spectra Optia Service Manual (885 pages)
apheresis system
Brand:
CaridianBCT
| Category:
Medical Equipment
| Size: 9 MB
Table of Contents
Table of Contents
5
Preface
19
1 : Operational Description
20
How to Use this Manual
20
Operational Description
21
System Components
23
Modes of Operation and Procedure States
25
User Interface
27
Exchange Disposable Tubing Set
31
Collection Disposable Tubing Set
35
Therapeutic Plasma Exchange
39
Mononuclear Cell Collection
42
Red Blood Cell Exchange Procedure Types
44
RBCX Functional Description
46
2 : System Description
47
System Description
47
E-Box and Computer Systems
49
Control CCA
51
Control Computer CCA
53
Control Ethernet CCA
54
Other Control Stack Ccas
55
Safety CCA
57
Safety Computer CCA
58
Other Safety Stack CCA
60
AIM System Ccas
60
Motor Driver CCA
64
Display CCA
72
Top Cap and Motherboard Ccas
74
Power System
75
Cooling Fans
78
Display System
79
Display Assembly
81
Pump System
84
Pump Assembly
87
Valve System
89
Valve Assembly
91
Sensor System
94
Pressure Sensors
94
Reservoir Level Sensors
98
Reservoir Management
101
Fluid Sensors
102
Return Line Air Detector
104
Set ID Detector
106
RBC Detector
109
Fluid Leak Detector
112
Linear Actuator System
114
AIM System
117
Camera System
117
Lighting System
119
Centrifuge System
127
Centrifuge Drive Assembly
131
Filler Assembly
133
Centrifuge Motor Controller
135
Mechanical System
138
Dual IV Pole
138
Wheel and Brake System
141
3 : Software Description
143
Software Description
143
Base Layer Software States
146
Power Control State
146
Startup State
149
T1 Pump Power Test State
154
T1 Device Test State
156
T1 APC Test State
158
T1 Centrifuge Power Test State
160
Load Disposable State
163
RBC Detector Calibration State
168
Disconnect Test State
170
Unload Disposable State
172
Set Layer Software States
174
Collection States
174
Exchange States
196
Protocol Layer Software States
219
MNC Run State
219
RBCX Run State
224
TPE Run State
230
4 Troubleshooting
237
Non-Alarm Troubleshooting
238
Touchscreen Troubleshooting
238
General AIM Troubleshooting
239
Troubleshooting Failures During Start up
241
Datalog Files
243
Alarm Troubleshooting
244
Spectra Optia Alarms
247
AC Fluid Detector Detected Fluid too Soon
248
AC Fluid Detector DID Not Detect Fluid
250
AC Infusion Data was Invalid
252
AC Infusion Data was Invalid
253
AC Occlusion Test Failed
254
AC Pump DID Not Stop When Commanded
256
AC Pump Malfunctioned
258
AC Pump Software Error Occurred
260
AC Pump Speed was too High
261
AC Pump Turned Faster than Inlet Pump
262
AC Volume Limit was Exceeded
264
AC was Not Detected
265
AIM Subsystem Failed
267
AIM System's Interface Measurement Data was Not Updated
269
AIM System Could Not Establish Target Interface
271
AIM System Detected RBC Interface Near Top of Channel
273
AIM System DID Not Complete Calibration Test
276
AIM System DID Not Complete Channel Imaging Test
278
AIM System DID Not Complete Illumination Test
280
AIM System DID Not Complete Interface Measurement
282
AIM System DID Not Detect Interface
284
AIM System DID Not Respond to System Command
287
AIM System Failed Calibration Test
289
AIM System Failed Channel Imaging Test
291
AIM System Failed Illumination Test
294
AIM System Failed to Measure Interface
297
Air May Not Have Been Removed from Return Line
300
Air Removal Is Complete
302
Air was Detected in Return Line
303
Analog Sensor Data was Not Available
305
Bolus Volume Caused Fluid Balance to Exceed Limits
306
Calculation of Pump Rpm was Not Consistent
308
Canceling Custom Prime Recommendation
310
Cassette Mechanism that Raises and Lowers Cassette Malfunctioned
311
Cassette Sensor Malfunctioned
313
Cassette Software Error Occurred
315
Cassette Tray was Not Correctly Positioned
316
Cassette was Not Detected in All Positions
318
Cassette was Not Lowered
320
Centrifuge Control Malfunctioned
321
Centrifuge DID Not Stop During Alarm
323
Centrifuge DID Not Stop When Commanded
324
Centrifuge Door Lock Malfunctioned
326
Centrifuge Door Lock Power Circuit Failed
327
Centrifuge Door Lock Sensor Malfunctioned
328
Centrifuge Door Lock Software Error Occurred
330
Centrifuge Door Lock Test Malfunctioned
331
Centrifuge Door Position Sensor Malfunctioned
333
Centrifuge Door was Not Closed
335
Centrifuge Door was Opened or Unlocked When Centrifuge was Spinning
336
Centrifuge Exceeded Maximum Allowed Speed
338
Centrifuge Motion Detected was Improper
340
Centrifuge Power Could Not be Disabled
342
Centrifuge Power Could Not be Enabled
343
Centrifuge Power DID Not Turn off
344
Centrifuge Pressure Exceeded Limit
346
Centrifuge Pressure Sensor Failed Calibration Test
349
Centrifuge Pressure Sensor Failed Post-Load Test
351
Centrifuge Pressure Sensor Failed Zero Differential Test
353
Centrifuge Pressure Sensor Failed Zero Limit Test
355
Centrifuge Pressure Sensor Failed Zero Range Test
357
Centrifuge Pressure Sensor Malfunctioned
359
Centrifuge Software Error Occurred
361
Centrifuge Speed Sensors Malfunctioned
362
Centrifuge Speed was Not Sufficient
364
Centrifuge Speed was too High While Procedure was Paused
366
Centrifuge was Commanded to Spin During Alarm
368
Centrifuge was Spinning in Reverse
369
Chamber Took too Long to Fill
371
Change Replacement Fluid to RBC for Exchange
373
Change to Patient Data Caused Fluid Balance to Exceed Limits
374
Check Connection from Return Line to Blood Warmer Tubing
377
Clamp Inlet and Return Lines
378
Clamp Inlet Line
379
Clamp Return Line
380
Clear Saline from Drip Chamber
382
Close Inlet Saline Line. Clamp Return Line
383
Close Lines to Prepare for Tubing Set Test
384
Close Return Saline Line
385
Close Return Saline Line
386
Close Saline Lines and Clamp Extra Remove Line
387
Collection Bag Reached Capacity
388
Collect Recirculation Flow Path was Not Primed
389
Confirming Selection to Begin Rinseback
391
Confirming Selection to Disable AIM System
392
Confirming Selection to Disable RBC Detector
393
Confirming Selection to Disconnect Patient and Raise Cassette
394
Confirm Return Line DID Not Contain Air
396
Confirm Saline Lines Were Closed
397
Control Flow was Not Consistent
398
Could Not Confirm Saline Lines Were Closed
399
Current Run Targets Could Not be Attained with Run Value Entered
400
Current Run Targets Could Not be Attained with Value Entered
401
Current Run Targets Could Not be Attained with Value Entered. System Paused
402
Custom Prime Volume was Not Sufficient
403
Door-Closed Sensor was Not Consistent
404
Door Lock Sensor was Not Consistent
406
Fan 1 Failed
408
Fan 1 Malfunctioned
410
Fan 2 Failed
412
Fan 2 Malfunctioned
414
Fan 3 Failed
416
Fan 3 Malfunctioned
418
Fluid Balance Change Caused Fluid Balance to Exceed Limits
420
Fluid Balance no Longer Exceeded Limits
422
Fluid Leak Detector Failed Self-Test
424
Hall Sensor and Encoder in AC Pump Malfunctioned
425
Hall Sensor and Encoder in Inlet Pump Malfunctioned
427
Hall Sensor and Encoder in Plasma Pump Malfunctioned
429
Hall Sensor and Encoder in Replace Pump Malfunctioned
431
Hall Sensor and Encoder in Return Pump Malfunctioned
433
High-Level Reservoir Sensor Detected Excess Fluid
435
High-Level Reservoir Sensor Detected Fluid too Soon
438
High-Level Reservoir Sensor DID Not Detect Fluid
440
High-Level Reservoir Sensor Failed Fluid Check
442
High-Level Reservoir Sensor Failed Timing Test
444
High-Level Reservoir Sensor Malfunctioned
446
Hypervolemia Condition was Possible
448
Hypervolemia Limit was Exceeded
449
Hypovolemia Condition was Possible
450
Hypovolemia Limit was Exceeded
452
Identification of Tubing Set DID Not Match Selected Procedure
453
Improper State Transition Occurred
455
Inlet:ac Ratio Data was Invalid
456
Inlet:ac Ratio Data was Invalid
457
Inlet:ac Ratio was above Maximum
458
Inlet:ac Ratio was below Minimum
459
Inlet Line Prime Failed
460
Inlet Line was Not Clamped
461
Inlet Pressure Sensor Failed Calibration Test
462
Inlet Pressure Sensor Failed Post-Load Test
464
Inlet Pressure Sensor Failed Zero Differential Test
466
Inlet Pressure Sensor Failed Zero Limit Test
468
Inlet Pressure Sensor Failed Zero Range Test
470
Inlet Pressure Sensor Malfunctioned
472
Inlet Pressure was too Low
474
Inlet Pump DID Not Stop When Commanded
476
Inlet Pump Malfunctioned
478
Inlet Pump Software Error Occurred
480
Inlet Saline Line was Obstructed
481
Inlet Saline Line was Obstructed During Rinseback
483
Interface Still Took too Long to Establish
484
Interface Took too Long to Establish
487
Internal Timing was Not Consistent
490
Leak was Detected in Centrifuge
492
LED Sensor Malfunctioned
495
Low-Level Reservoir Sensor Continued to Detect Excess Fluid
496
Low-Level Reservoir Sensor Detected Air
499
Low-Level Reservoir Sensor Detected Excess Fluid
501
Low-Level Reservoir Sensor Detected Fluid too Soon
504
Low-Level Reservoir Sensor DID Not Detect Fluid
506
Low-Level Reservoir Sensor Failed Timing Test
508
Low-Level Reservoir Sensor Malfunctioned
510
Low-Level Reservoir Sensor Malfunctioned
512
Low-Level Reservoir Sensor Malfunctioned
514
Low-Level Reservoir Sensor Persisted in Detecting Excess Fluid
515
Minus Twelve Volt Power Supply was out of Range
518
NVRAM Safety Test Failed
519
NVRAM Test Failed
520
Open and Close Centrifuge Door
521
Open Inlet Saline Line
522
Open Return Saline Line
523
Open Saline Lines
524
Patient's Fluid Balance May be 10% Higher than Reported
525
Patient's Fluid Balance May be 10% Lower than Reported
527
Patient's Fluid Balance May be 15% Higher than Reported
529
Patient's Fluid Balance May be 15% Lower than Reported
531
Patient's Fluid Balance May be 5% Higher than Reported
533
Patient's Fluid Balance May be 5% Lower than Reported
535
Patient Fluid Balance May be Lower than Reported
537
Patient Height was Invalid
539
Patient Height was Invalid
540
Patient Hematocrit Data was Invalid
541
Patient Hematocrit Data was Invalid
542
Patient Sex was Invalid
543
Patient TBV was Invalid
545
Patient Weight was Invalid
547
Patient Weight was Invalid
548
Pause Button was Touched
549
Plasma Bag Reached Capacity
550
Plasma Pump DID Not Stop When Commanded
551
Plasma Pump Malfunctioned
553
Plasma Pump Software Error Occurred
555
Plasma Recirculation Flow Path was Not Primed
556
Plasma Remove Flow Path was Not Primed
558
Plasma Valve Malfunctioned
560
Plasma Valve Sensor Malfunctioned
561
Plasma Valve Software Error Occurred
562
Plasma Valve was Not Correctly Positioned
563
Predicted Fluid Balance Exceeded Limits
564
Predicted Procedure Time Exceeded 8 Hours
566
Prediction Software Malfunctioned
567
Pressure in Collect Line was too High
569
Pressure Sensor 4 Failed Calibration Test
571
Pressure Sensor 4 Failed Post-Load Test
573
Pressure Sensor 4 Failed Zero Differential Test
575
Pressure Sensor 4 Failed Zero Limit Test
577
Pressure Sensor 4 Failed Zero Range Test
579
Prime Saline Has Been Diverted. Close Return Saline Line
581
Prime Saline was Not Diverted
582
Procedure Configuration Data was Corrupt
583
Procedure Data Error Detected
584
Procedure Time Exceeded 8 Hours
586
Pump 1 Failed Rotation Test
587
Pump 2 Failed Rotation Test
589
Pump 3 Failed Rotation Test
591
Pump 4 Failed Rotation Test
593
Pump 5 Failed Rotation Test
595
Pump DID Not Function Correctly
597
Pump Motion Detected was Improper
599
Pump Power Could Not be Disabled
600
Pump Power Could Not be Enabled
601
Pumps and Centrifuge DID Not Stop During Alarm
602
Pumps Continued to Turn During Alarm
603
Pumps DID Not Stop During Alarm
604
Pumps Have Been Paused for 10 Minutes
605
Pumps Have Been Paused for 3 Minutes
606
Pumps Were Commanded to Turn During Alarm
607
Pumps Were Commanded to Turn Instead of Stop
608
Pumps Were Paused for 3 Minutes
609
Pumps Were Turned During Alarm
611
RBC Detector Calibration Error Occurred
612
RBC Detector DID Not Respond
614
RBC Detector DID Not Transmit Data
616
RBC Detector Software Error Occurred
618
RBC Recirculation Flow Path was Not Primed
619
RBC Remove Flow Path was Not Primed
621
RBC Valve Malfunctioned
623
RBC Valve Malfunctioned
624
RBC Valve Sensor Malfunctioned
625
RBC Valve Software Error Occurred
626
RBC Valve was Not Correctly Positioned
627
Read-Type Communication Error from RBC Detector Occurred
628
Recommending Custom Prime
630
Red Blood Cells Were Detected in Collect Line too Soon
631
Red Blood Cells Were Detected in Plasma Line from Centrifuge
634
Remove Bag Reached Capacity
637
Remove Valve Malfunctioned
638
Remove Valve Sensor Malfunctioned
639
Remove Valve Software Error Occurred
640
Remove Valve was Not Correctly Positioned
641
Replacement Fluid Detector Detected Fluid too Soon
642
Replacement Fluid was Not Detected
644
Replace Pump DID Not Stop When Commanded
646
Replace Pump Malfunctioned
648
Replace Pump Software Error Occurred
650
Reservoir DID Not Contain Enough Fluid
651
Reservoir Sensors Malfunctioned
652
Reservoir was Full During Air Removal
653
Return Line Air Detector Detected Fluid too Soon
655
Return Line Air Detector Failed Fluid Check
657
Return Line Prime Failed
659
Return Line was Not Clamped During Air Removal
661
Return Line was Not Primed
663
Return Pressure Sensor Failed Calibration Test
665
Return Pressure Sensor Failed Post-Load Test
667
Return Pressure Sensor Failed Zero Differential Test
669
Return Pressure Sensor Failed Zero Limit Test
671
Return Pressure Sensor Failed Zero Range Test
673
Return Pressure was too High
675
Return Pressure was too High When System was Diverting Saline
677
Return Pump DID Not Stop
678
Return Pump DID Not Stop When Commanded
679
Return Pump Malfunctioned
681
Return Pump Malfunctioned
683
Return Pump Software Error Occurred
685
Return Pump Speed was too High
686
Return Pump Turned too Fast
688
Return Saline Line Failed Integrity Test
690
Return Saline Line was Not Closed During Air Removal
692
Return Saline Line was Obstructed
694
Return Saline Line was Obstructed During Air Removal
696
Run Target will be Attained before Next Collection Phase
698
Safety System Could Not Confirm Position of Collect Valve
699
Safety System Could Not Confirm Valve Position
700
Safety System Could Not Read Backup Configuration File
702
Safety System Could Not Read Default Configuration File
703
Safety System Could Not Read Primary Configuration File
704
Safety System Detected Air in Return Line
705
Safety System Detected Air in Return Line
706
Safety System Detected Excess AC Infusion
707
Safety System Detected Internal Timing Inconsistency
709
Safety System Detected Software Communication Error
711
Safety System Detected that Patient Hematocrit was Lower than Minimum
713
Safety System Detected too Much Fluid in Collection Bag
714
Safety System Detected too Much Fluid in Plasma Bag
715
Safety System Detected too Much Fluid in Remove Bag
716
Safety System Detected Valve Open Longer than Expected
717
Safety System DID Not Respond to Power Request
719
Safety System DID Not Respond to Request to Turn off Power
720
Safety System DID Not Respond to Request to Turn on Power
721
Safety System Failed Power Test
722
Safety System Failed Start Process
724
Safety System Lost Internal Communication Capability
726
Safety System Stopped Air Removal
728
Saline Lines Were Not Closed
729
Saline Line was Obstructed
730
Sixty-Four Volt Power Supply was out of Range
732
Software Consistency Error Occurred
733
Software Control Data was Not Updated
734
Software CRC Failed
736
Software Memory for AIM System was Not Sufficient
737
Software Memory for Control System was Not Sufficient
738
Software Memory for Safety System was Not Sufficient
739
Software Module was Not Consistent
740
Stop Button was Touched
741
System Cannot Verify that Patient was Disconnected
742
System Could Not Load Correct Software
743
System Could Not Read Backup Configuration File
744
System Could Not Read Default Configuration File
745
System Could Not Read Primary Configuration File
746
System DID Not Correctly Monitor AC Infusion
747
System Malfunctioned When It Raised or Lowered Cassette
749
System Paused: Centrifuge Door was Not Closed
750
System was Reset
752
System was Reset
754
System was Reset
756
TBV Restricted Volume Available to Confirm Volume in Reservoir
757
Test of Negative Inlet Pressure Failed
758
Test of Negative Return Pressure Failed
760
Timing Discrepancy in Low-Level Reservoir Sensor Occurred
762
Too Much AC was Detected During Prime
764
Tubing Set DID Not Match Selected Procedure
765
Tubing Set Failed Dwell Test for Negative Inlet Pressure
767
Tubing Set Failed Dwell Test for Negative Return Pressure
769
Tubing Set Failed Dwell Test for Positive Inlet Pressure
771
Tubing Set Failed Dwell Test for Positive Return Pressure
773
Tubing Set Failed Test for Negative Inlet Pressure
775
Tubing Set Failed Test for Positive Inlet Pressure
777
Tubing Set Failed Test for Positive Inlet Pressure
779
Tubing Set Failed Test for Positive Return Pressure
781
Tubing Set Failed Test of Negative Return Pressure
783
Tubing Set Identification Error Occurred
785
Tubing Set May Have Contained Fluid
788
Twelve Volt Power Supply was out of Range
790
Twenty-Four Volt Power Supply was out of Range
791
Unclamp Return Line
792
Valve Position Error Occurred
794
Vent Bag Contained Fluid During Prime
796
Vent Bag Contained Fluid During Run
798
Verification Test that Patient was Disconnected from Inlet Line Failed
800
Verification Test that Patient was Disconnected from Return Line Failed
801
Voltage of Fluid Leak Detector was above Normal Range
802
Voltage of Fluid Leak Detector was below Normal Range
803
Volume Entered for Custom Prime was too Low
805
Volume in Collection Bag May be Lower than Reported
806
Write-Type Communication Error to Data Logging Subsystem Occurred
808
Write-Type Communication Error to RBC Detector Occurred
809
5 : Maintenance and Calibration
811
Maintenance and Calibration
811
Removing the Side Panels
812
Raising the Pump Panel
815
Removing the Linear Actuator
818
Calibrating the Centrifuge Motor Controller
820
Making a Test Cassette
822
Positioning the Linear Actuator Sensors
824
Connecting a Printer
828
Connecting a Computer
830
6 : Spectra Optia Spare Parts
847
Literature Group
848
Documentation Group
848
Display Head Group
849
Pump Panel Group
850
Centrifuge Basin Group
852
E-Box Group
853
Seal Safe Group
855
Exterior Parts Group
856
Tools Group
857
Other Parts Group
857
Software Group
858
Software Multipack Group
860
Specifications
861
Touch Screen
867