Sign In
Upload
Manuals
Brands
Campbell Manuals
Accessories
C477
Campbell C477 Water Level Sensor Manuals
Manuals and User Guides for Campbell C477 Water Level Sensor. We have
1
Campbell C477 Water Level Sensor manual available for free PDF download: Instruction Manual
Campbell C477 Instruction Manual (40 pages)
Radar Water Level Sensor
Brand:
Campbell
| Category:
Accessories
| Size: 0.84 MB
Table of Contents
Table of Contents
3
1 Overview
5
2 Specifications
6
CS475, CS476, and CS477
6
3 Installation
8
General Safety Instructions
8
Unpacking Equipment
8
Components and Hardware
8
Components and Hardware
9
Description of Components and Hardware Labels
9
Installation Recommendations
10
Site Selection
10
Sensor Mounting
11
Vertical Alignment
11
Azimuth Alignment
11
Radiation Beam Spread for CS475 (10° Beam Angle)
11
Radiation Beam Spread for CS476/CS477 (8° Beam Angle)
11
Instrument Housing Adjustment
12
Description of Polarization Markings Labels
12
4 Wiring
13
Datalogger Connection
13
Multiple Sensors Connection
13
Built-In Self Test (BIST)
13
Wiring Diagram
13
5 Configuration
14
Default Settings
14
Startup Procedure
14
Start False Echo Learn
14
Set Water Stage
15
Example of a Start False Echo Learn Command
15
6 Programming
16
Crbasic
16
Example for Setting Water Stage
16
Example Program
17
SDI-12 Command Codes
17
Edlog
18
Example Program
19
7 Diagnostics, Repair, and Maintenance
20
Testing Procedure
20
Start Measurement Command
20
Check Unit Response
21
Check for Valid Data
21
Example of Start Measurement Command
21
Acknowledge Active Command
21
Cyclic Redundancy Check (CRC)
22
Check CRC for Valid Data
22
Send Identification Command
22
Get Units
23
Get Water Conditions
23
Get Power Operation Mode
23
Checking CRC Example
23
Diagnostics and Repair
24
No Measured Value Available - Error E013
24
No Measured Value Available - Error E041, E042, E043
24
Exchange Electronics Module
24
Description of Changing the Electronics Labels
26
Maintenance
27
A-1. Description of Instrument Housing Labels
30
B-1. SDI-12 Commands
32
Changing Settings
33
Query/Set the Address
33
Set Units
33
B-2. SDI-12 Command for Querying the Address
33
B-3. Example of Setting Address
33
Set Water Conditions
34
Set Power Operation Mode
34
B-5. Example for Setting Water Conditions
34
B-6. Example for Setting Power Operation Mode
35
Advertisement
Advertisement
Related Products
Campbell CS105
Campbell cs215
Campbell CS476
Campbell CS210
Campbell CS140
Campbell CS440
Campbell CS11
Campbell CS240
Campbell CS475A
Campbell CS725
Campbell Categories
Measuring Instruments
Accessories
Modem
Weather Station
Recording Equipment
More Campbell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL