Table of Contents
Table of Contents
3
About this Document
8
Manufacturer
8
Symbols Used
8
Terms and Abbreviations
9
Safety Instructions
9
Intended Use
9
Safety
9
Product
11
Product Overview
11
Product Digital Output
11
Type Label
12
Technical Data
13
Conditions of Use
13
Standards and Directives
13
Conformity to the Pressure Equipment Directive
13
UL Certification
14
Materials
15
Dimensions
16
Fluid Data
16
Electrical Data
18
Ph Probe, Redox Probe
19
Modify Cover Orientation and Install Probe
19
Safety Instructions
19
Unscrewing the Cover on the Connection Box
20
Fitting the Cover to the Connection Box
20
Fitting the Probe into the Holder (Without Fluid)
21
Installation and Wiring
22
Safety Instructions
22
Installation on the Pipe
22
Fitting the Electronic Module to the Holder
24
Electrical Installation
25
Io-Link Communication
26
Safety Instructions
26
Communication Table
27
Iodd
27
Connection to the IO-Link Master
28
Setting and Operation in IO-Link
28
Home Page
28
Identification
29
Parameter
29
Observation
33
Diagnostic
34
Setting and Operation in Büs
35
Safety Instructions
35
Setting Tools and Setting Software
36
Description of the User Interface
36
Available Login User Levels
36
Product Functions and Menus
37
Sensor - Parameter
37
Setting Sensor Parameters
38
Sensor
38
Measurement Type
38
Mains Frequency
39
Setting Parameter for each Measured Values
39
Set the Filter Response Time of a Measured Value
39
Activating the Monitoring of Measured Values
40
Deactivating the Monitoring of Measured Values
43
Changing the Error Limits, the Warning Limits and the Hysteresis of the Measured Values
43
Activate Display of Reference Impedance and Glass Impedance
43
Deactivate Display of Reference Impedance and Glass Impedance
44
Configure Reaction of the Device to Specific Events
44
Activating the Monitoring of an Event
44
Deactivating the Monitoring of an Event
44
Resetting to Factory Default Parameter Data
45
Sensor - Diagnostics
45
Sensor - Maintenance
46
Checking the Output Behaviour
47
Calibration of the Ph Sensor
47
Calibration Temperature
47
Calibration PH Sensor
47
Calibration Redox („ORP") Sensor
51
Offset / Slope
52
Setting Temperature Offset
52
Configure Calibration Schedule
52
Resetting Calibration Data to Factory Default Value
52
General Settings - Parameter
53
Changing the Operating Mode of the Device Status Indicator or Switching off the Device Status Indicator
53
Changing the Operating Mode of the Device Status Indicator
53
Switching off the Device Status Indicator
54
Setting the Basic Parameters for Identifying the Device on Büs
54
Entering a Name for the Device
54
Entering the Location of the Device
54
Entering a Description for the Device
54
Setting the Advanced Parameters for Identifying the Device Connected to Büs or to a Canopen Bus
55
Entering a Unique Name for the Device
55
Changing the Transmission Speed on the Device
55
Changing the Address of the Device Connected to a Canopen Bus
56
Setting the Digital Communication for Büs or for a Canopen Bus
56
Stop Sending the Measured Process Data (Pdos) to Büs or to the Canopen Fieldbus
57
Monitoring the Supply Voltage or the Device Temperature
57
Reading out the 2 Error Limit Values
57
Changing the 2 Warning Limit Values
58
Reading out the Hysteresis Value
58
Activating the Diagnostics Function
58
Disabling All the Diagnostics
59
Pdos Configuration
59
Set the Transmission Time between 2 Val
59
Ues of a PDO
59
Restore All Pdos to Their Default Values
59
General Settings - Diagnostics
60
Reading out Device Status Information
60
Reading out Büs Status Information
61
Resetting Errors Counter
61
Read the Generated Events
61
General Settings Maintenance
63
Restart the Product
63
Reset the Product to Its Factory Settings
63
Process Data Objects
64
Transmitted Pdos
64
Structure of the PDO4
64
Maintenance
66
Safety Instructions
66
Cleaning the Device
66
Replacing the Probe
67
Replacing the Seal in the Probe Holder
68
Troubleshooting with Messages
69
Messages : Failure, Error or Malfunction
69
Message Büs Is Not Operational
69
Message Factory Data Failure
69
Message Temperature Failure
69
Message Sensor Connection Lost
69
Message Measurement Saturation Error
70
Message Error: too Low Ph
70
Message Error: too High Ph
70
Message Error: too Low ORP
70
Message Error: too High ORP
71
Message Error: too Low Temperature
71
Error: too High Temperature
71
Error: too Low Voltage
71
Error: too High Voltage
72
Error: too Low Reference IM
72
Pedance
72
Error: too High Reference
72
Impedance
72
Error: too Low Glass Impedance
72
Error: too High Glass Impedance
73
Function Check
73
Message Simulation Mode Active
73
Out of Specification
74
Message Warning: too Low Ph
74
Message Warning: too High Ph
74
Message Warning: too Low ORP
74
Message Warning: too High ORP
74
Message Warning: too Low Temperature
75
Message Warning: too High Temperature
75
Message Warning: too Low Voltage
75
Message Warning: too High Voltage
75
Message Warning: too Low Reference
76
Impedance
76
Message Warning: too High Reference
76
Message Warning: too Low Glass Impedance
76
Message Warning: too High Glass Impedance
76
Messages : Maintenance Required
77
Message Calibration Date Has Expired
77
Spare Parts and Accessories
77
Packaging, Transport
78
Storage
78
Disposal
78
Advertisement
Burkert ELEMENT neutrino 8202 Operating Instructions Manual (44 pages)
pH or redox meter
Brand:
Burkert
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
The Operating Instructions
5
Symbols Used
5
Definition Of The Term Device
5
Intended Use
6
Basic Safety Information
6
Validity Of The Operating Instructions
6
Description
8
General Information
8
Manufacturer's Address And International Contacts
8
Warranty Conditions
8
Information On The Internet
8
Construction
8
Type Label
9
Technical Data
10
Conditions Of Use
10
Conformity To Standards And Directives
10
Conformity to the Pressure Equipment Directive
10
UL Certification
11
Materials
12
Dimensions
13
Fluid Data
13
Electrical Data
15
Ph Probe, Redox Probe
15
Assembly
16
Safety Instructions
16
Unscrewing The Cover On The Connection Box
16
Fitting The Cover To The Connection Box
17
Installation
18
Safety Instructions
18
Fitting The Probe Into The Holder (Without Fluid)
18
Installation On The Pipe
19
Fitting The Electronic Module To The Holder
21
Electrical Wiring
22
Electrical Connections
22
Wiring a Device Variant with Cable Gland
23
Assembling and Wiring the Female Connector, Article Number 917116
24
Nector
25
Adjustment And Start-Up
26
Safety Instructions
26
Description Of The Connection Box
27
Selecting The Measurement Mode: Ph Or Redox
27
Choosing the Ph, Redox Potential or Temperature Range Associated with the 4
28
Calibrating The Ph Or Redox Probes
29
1-Point Calibration: Zero Adjustment
30
Calibration Thresholds of the Probe
31
2-Point Calibration (Ph Only): Zero and Slope Adjustments
32
Maintenance And Troubleshooting
34
10.1. Safety Instructions
34
10.2. Cleaning the Device
34
10.3. Replacing the Probe
35
Replacing The Seal In The Probe Holder
36
Replacing The Cover Seal On The Connection Box
37
10.6. in Case of Problems, Excluding Calibration
39
Spare Parts And Accessories
40
Storage
41
Disposal Of The Device
41
Packaging, Transport
41
Advertisement
Related Products
Burkert AirLINE Ex 8650
Burkert ELEMENT
Burkert IECEx EPS 16.0030X
Burkert E504714
Burkert ELEMENT Series
Burkert EVA Series
Burkert 285877
Burkert 285880
Burkert 286100
Burkert 286212
Burkert Categories
Control Unit
Controller
Measuring Instruments
Transmitter
Accessories
More Burkert Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL