BioSpec 117 AVANCE III
Bruker BioSpec 117 AVANCE III Manuals
Manuals and User Guides for Bruker BioSpec 117 AVANCE III. We have
1
Bruker BioSpec 117 AVANCE III manual available for free PDF download: Manual
Bruker BioSpec 117 AVANCE III Manual (102 pages)
MRI
Brand:
Bruker
| Category:
Medical Equipment
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Intended Use
7
Using the Documentation
7
Additional Documents
8
Responsibilities
8
Validity
8
2 Safety
9
Warning Notices
9
Safety Instructions for the Planning Stage
10
Magnetic Fields
10
Figure 2.1: Fig. 2.1: Hazardous Zones
10
Control Area
11
Exposed Area
11
Exhaust System
11
Safe Handling of Cryogen Liquids
11
O2 Supervision
12
Emergency Plan
12
Fire Prevention
13
Biological Safety
13
Seismic Safety
13
Safety at Work
13
Central Monitoring of the MR System
14
3 Standards and Certification
15
Standards
15
Environmental Conditions
15
National Standards for Operating MR Systems
16
4 Installation Schedule
17
Installation Planning Overview
17
Figure 4.1: Fig. 4.1: Installation Planning Overview
17
Planning Aids
19
Installation Schedule
19
Prerequisites for Delivery
19
Giving Notice of Readiness for Shipment
19
Prerequisites for Operation
20
5 Laboratory Infrastructure and Interactions
21
Operational Procedures
21
Structures
21
Interactions
22
Magnetic Interactions
22
Ferromagnetic Mass
22
Mobile Sources of Magnetic Disturbance
23
Figure 5.1: Mobile Sources of Magnetic Interference
23
Effect of MR System to Other Equipment
24
Remote Magnetic Effects
24
Table 5.1: Limit Values of Magnetic Disturbances
24
Table 5.2: Interference Fields of Equipment
24
Electromagnetic Interactions
25
DC and LF Interference
25
Table 5.3: Disturbance in the Magnet Room
25
Table 5.4: Disturbance in the Technical Room
25
RF Interference
26
Table 5.5: Disturbance in the Vicinity
26
Table 5.6: Frequency Ranges for Commonly Used NMR Nuclei
26
Figure 5.2: Installation in an RF Shielded Cabin (Faraday Cage)
27
Table 5.7: Maximum Disturbance Level
27
Table 5.8: Biospec RF Shielding Measure
27
Mechanical Interactions
28
Ground and Building Vibrations
28
Figure 5.3: Installation with an Autopac™ RF Shield
28
Figure 5.4: Limit Values of the Floor Vibrations
29
Table 5.9: Max. Acceptable Accelerations Within Different Frequency Ranges
29
Impact Noise
30
Acoustic
30
6 Planning Details
31
Measurements and Room Dimensions
31
Overview
31
Figure 6.1: Diagram of the Manufacturer's Room Constraints
31
Operating Area
32
Magnet Area
32
Figure 6.2: Magnet Area and Dimensions. no Fire-Prevention Facilities Requiring Regular Maintenance Work May be Incorporated in the Areas Shaded Red above the Magnet
32
Table 6.1: Minimum Space Required for Magnets
32
Figure 6.3: Stray Field
33
Technical Area
34
Figure 6.4: Minimum Space Required in the Technical Area
34
HF Shielded Room
35
Table 6.2: Measurements of Objects in the Technical Area
35
Table 6.3: Measurements of the MRI Cryoprobe™ Units in the Technical Area
35
Table 6.4: Measurements of the MRI Parallel Transmit™ Units in the Technical Area
35
Filter Plates
36
Table 6.5: Verwendung von Filterplatten nach Ausstattung
37
Figure 6.5: Assembly of Filter Plates with an Installation Frame (Right) and Directly Screwed to the Cage
38
Figure 6.6: Dimension Diagram of Filter Plates
39
Electronic Filter Plate
40
Magnet Filter Plate
40
Filter Plate for Anesthetic Gas Exhaust
40
Table 6.6: Measurements of the Individual Filter Plates
40
Filter Plate for Magnet Exhaust System
41
MRI Cryoprobe™ Filter Plate
41
In-Vivo Filter Plate
41
Filter Plate for Faraday Cage Ventilation
41
Exhaust System
42
Figure 6.7: Measurements of Faraday Cage Ventilation Filter Plate
42
Figure 6.8: Exhaust Vent System
43
Design Criteria of the Exhaust System
44
Figure 6.9: Schematic Diagram of the Exhaust Vent Supplied. the Distance Q Is Measured from the Center of the Dewar Vessel of the Magnet
44
Calculating the Exhaust System
45
Table 6.7: Effects of Force
45
Table 6.8: Pressure Drop in USR Magnet Cable Elements: 47/40, 70/30, 94/20, 117/16
45
Floor Construction
46
Figure 6.10: Section of the Exhaust Vent
46
Surface Loads and Weights
47
Table 6.9: Surface Loads and Weights
47
Magnet Foundation
48
Figure 6.11: Construction of the Magnet Foundation, if the Original Floor Construction at the Magnet Installation Site Is Based on a Floating Floor
48
Figure 6.12: Position of the Magnet on the Foundation; Position of the Vibration Absorber (1) and of the
49
Electrostatic Discharge
50
Seismic Safety Standards
50
Table 6.10: Maximum Underground Acceleration with Seismic Protection
50
Table 6.11: Floor Construction and Anchorage for Seismic Safety
51
Figure 6.13: Seismic Protection System in an HF Shielding Box with "Faraday Cage Connection Kit
52
Electrical Installations
53
Overview
53
Figure 6.14: Seismic Protection System on the Magnet
53
Main Connection
54
Figure 6.15: TN-S Connection Diagram of the MR System (60Hz)
54
Figure 6.16: TN-S Connection Diagram of the MR System (50 Hz)
55
Table 6.12: Connection Values in the Technical Room
55
Central Potential Compensation
56
Electrical Connections in the Magnet Room
56
Electrical Connections in the Operating Room
56
Table 6.13: Equipotential Bonding Terminal Characteristics in the Technical Room
56
Table 6.14: AC Sockets in the Operating Room
56
Connection and Assembly of Electrical Distributor
57
Supervision Signals
57
Figure 6.17: Schematic Diagram of the Electrical Distributor
57
Cable Lengths and Routing
58
Figure 6.18: Overview of the External Line Set
59
Table 6.15: Available Cable Lengths of the Electrical Connections
59
Figure 6.19: Cable Routing between Technical Room and Magnet Room
60
Figure 6.20: Construction of Cable Carrying System
61
Line Lengths for the MRI Cryoprobe
62
Lighting System
63
Ventilation and Air Conditioning
63
Overview
63
Table 6.16: Overview of the Types of Cooling System
63
Air Conditioning Systems
64
Table 6.17: Cooling Performance of the Air-Conditioning System in the Magnet Room
64
Table 6.18: Performance of the Space Cooling in the Technical Room
64
Anesthetic Gas Extraction
65
Figure 6.21: Anesthetic Gas Extraction
65
Table 6.19: Further Requirements for the Space Cooling in the Technical Room
65
Cold Water Supply
66
Table 6.20: Heat Dissipated to the Cold Water System
66
Connections and Installation
67
Table 6.21: Specifications for the Water Quality
67
Figure 6.22: Water Supply Installation in the Technical Room
68
Cryogen Liquids
70
Compressed Air and Gas Supply
70
MRI Cryoprobe
70
Table 6.22: Fill Quantity Cryogen Liquids
70
Laboratory Furnishings
71
Laboratory Furniture
71
7 Delivery and Transport
73
Maximum Transport Time
74
Packaging
74
Figure 7.1: Shock Indicators
74
Magnet Transport
75
Transport Method and Limit Value
75
Figure 7.2: Transport Pallets for Air Freight
75
Figure 7.3: Transportation Using Heavy Duty Rollers
76
Table 7.1: Transport Limitations
76
Transporting Electronic Cabinets
77
Transport Method and Limits
77
Moving into the Building
78
Table 7.2: Transport Limitations
78
Figure 7.4: Transport Dimension of the Magnet. (1) in the Standard Transport Situation and (2) for the Case, When the U-Rails Are Removed
79
Figure 7.5: Unloading Situation of Transport by Lorry
80
Moving under Special Circumstances
81
Figure 7.6: Separatable Transport Container
81
8 Moving or Dismantling the MR System
83
9 Checklist for Preparing to Install the System
85
Customer Information
85
Magnet Installation
86
Laboratory Rooms Features
88
Declaration
90
Figures Figures
91
Index
95
Advertisement
Advertisement
Related Products
Bruker BioSpec 16 AVANCE III
Bruker SkyScan 1272
Bruker SMART X2S
Bruker Categories
Laboratory Equipment
Measuring Instruments
Industrial Equipment
Security Sensors
Amplifier
More Bruker Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL