Sign In
Upload
Manuals
Brands
BRUEL & KJAER Manuals
Measuring Instruments
2033
BRUEL & KJAER 2033 Manuals
Manuals and User Guides for BRUEL & KJAER 2033. We have
1
BRUEL & KJAER 2033 manual available for free PDF download: Instruction Manual
BRUEL & KJAER 2033 Instruction Manual (107 pages)
High Resolution Signal Analyzer
Brand:
BRUEL & KJAER
| Category:
Measuring Instruments
| Size: 59.03 MB
Table of Contents
Table of Contents
5
Controls Used for Analog Input and General Operation
11
Controls Used to Set the Triggering Conditions
13
Controls Used in Recording and Transformation of Data
14
Controls Used in Averaging of Data
15
Use of the Reference Memory
15
Controls Used in the Display of Data
16
1 Introduction and Specifications (Product Data)
21
2 Controls
21
Front Panel of the High Resolution Signal Analyzer Type 2033
21
Controls Used in the Input/Output of Data
28
The 2033 Display Screen
29
The 2033 Display Screen in Display of a Time Function
29
The 2033 Display Screen in Display of a Spectrum
30
Rear Panel of the High Resolution Signal Analyzer Type 2033
31
3 Installation and Calibration
34
Installation and Preliminary Adjustments
34
Environment
34
Mounting
34
Connection of Mains Supply
35
Grounding Considerations
36
Initial Control Settings
36
Calibration
37
Calibration in Db Using a Sinusoidal Reference
37
Calibration in Db Using an External Noise Source
39
Calibration in Volts
40
Calibration in Engineering Units
40
Calibration in the Analysis of Transient Data
40
General Operational Procedure
41
4 Recording
42
Selection of Trigger Source
43
INFLUENCE of the TRIGGER "Samples after Trig." CONTROL
43
The "Samples after Trig." Control in High Resolution Mode
44
The "Samples after Trig." Control in Baseband Mode
44
The Transformed Record Length in Baseband and High Resolution Mode
45
Control of Recording
45
Baseband Mode
46
High Resolution Mode
46
Use of RECORD "Single
46
Manual Selection of RECORD "Stop
47
Display of Time Domain Data
47
Control of Time Domain Data Display
48
Use of the 2033 LINE SELECTOR to Read Time Domain Data from the 2033 Display Screen
49
5 Analysis and Display of Spectra, Baseband Mode
51
Control of Averaging, Baseband Mode
51
Linear Averaging
52
Exponential Averaging
53
Hold Max
54
Display of Baseband Spectra
54
Display of a Spectrum
54
Display of the Ratio between Spectra
56
Use of an External Sampling Frequency in Baseband Mode
56
Use of the Tracking Frequency Multiplier Type 1901 with the 2033
57
6 Analysis and Display of Spectra, High Resolution Mode
58
Analysis of Spectra, High Resolution Mode
58
Averaging and Display of Spectra in High Resolution Mode
59
Measurement of 4000-Line Spectra
60
Use of an External Sampling Frequency in High Resolution Mode
60
Tracking Zoom
63
7 Analysis of Transient and Non-Stationary Signals
65
Analysis of Transient and Non-Stationary Signals, Baseband Mode
66
Analysis of Single Transients
67
Automatic Transient Averaging
67
Manual Averaging of Transients with Rejection of Bad Data
67
Analysis of Machine Cycles
68
Analysis of Transient and Non-Stationary Signals, High Resolution Mode
69
Measurement of the 4000-Line Spectrum of a Transient
69
Scan Analysis
69
Operation of a Scan Analysis
70
Scan Analysis with Manual Control
71
Scan Averaging
71
8 Output of Data
73
Analog Output from the 2033
73
Analog Output to a Level Recorder Type 2307
73
Analog Output to an X-Y Recorder Type 2308
76
Exchange of the Level Recorder and X-Y Recorder Interfaces
77
Digital Read-Out under Manual Control
79
Read-Out to an Alphanumeric Printer Type 2312
79
Read-Out to and Read-In from a Digital Cassette Recorder Type 7400
79
9 Digital Data Transfer and Remote Control Via the Iec Interface
81
Iec Functions Implemented
82
Selection of Addresses
82
Codes for Addressing 2033 Controls
83
Frequency
84
TRIGGER "Samples after Trig
84
AVERAGING "No. of Spectra
84
Trigger Level
85
INPUT "Att. 0 - 100 Db
85
TIME FUNCTION "Move
86
Spectrum Gain
86
Line Selector
87
Centre Frequency
87
Other Controls, Upper Front Panel of 2033
88
Other Controls, Lower Front Panel of 2033
89
Differences between Remote and Manual Control of the 2033
89
Required Formats for Digital Input and Output over the 2033 Iec Interface
90
Mode # 0, Digital Input/Output of an ASCII Encoded Spectrum
90
Mode # 1, Remote Setting of Pushkeys and Output of Pushkey Settings
91
Mode # 2, Digital Input/Output of a Time Record
92
Mode # 3, Block Transfers MSBY - LSBY to and from the 2033
93
Mode # 4, ASCII Sensing of Pushkeys
94
Mode # 5, Digital Output of 2'S Complement Encoded Spectrum
94
Mode # 6, Block Transfers LSBY to and from the 2033
95
Mode
95
Mode # 8, Carry on Processing
95
Mode # 9, Reset 10 K Time Function Buffer
95
Other Input/Output Modes, Manual Digital Input/Output
95
Other Input/Output Modes, Input of Text to the IEC Text Line
96
Other Input/Output Modes, Output of Text from 2033 Text Line
97
Use of Interrupts in 2033 Data Transfers
97
Read-Out of the Complex Spectrum with Interrupt Control
98
Use of Service Request in Read-Out of Instantaneous and Averaged Spectra
98
Formats Used in Block Transfers
99
Format of a Time Record
99
Format of the Complex Spectrum
99
Format of the Instantaneous Power Spectrum
100
Format of the Averaged Power Spectrum
100
Format of the Reference Memory
101
Format of Display Buffer
102
Speed of Digital Input and Output
102
10 Service and Repair
103
Advertisement
Advertisement
Related Products
BRUEL & KJAER 2031
BRUEL & KJAER 2006
BRUEL & KJAER 2034
BRUEL & KJAER 2004
BRUEL & KJAER 2005
BRUEL & KJAER 2240
BRUEL & KJAER 2221
BRUEL & KJAER 2260
BRUEL & KJAER 2226
BRUEL & KJAER 2237
BRUEL & KJAER Categories
Measuring Instruments
Test Equipment
Amplifier
Microphone
Analytical Instruments
More BRUEL & KJAER Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL