Manuals and User Guides for Brooks firetracker FT1020G3 FDCIE. We have
2
Brooks firetracker FT1020G3 FDCIE manuals available for free PDF download: Operation Manual, Quick Operation Manual
Brooks firetracker FT1020G3 FDCIE Operation Manual (162 pages)
Brand:
Brooks
| Category:
Smoke Alarm
| Size: 3.5 MB
Table of Contents
Table of Contents
3
1 Introduction
8
Overview
8
Definitions / Explanations
8
Table 1 Definitions and Explanations
8
TLON Network
10
2 General Description
11
The FT1020G3 FDCIE
11
Technical Address
11
Presentation Number
11
Com Loop Units
11
Figure 1 Connection Diagram of FT1020G3
11
Address and Mode
12
Software (S/W) Versions
12
Applications
12
3 Fire Detection Control & Indicating Equipment (FDCIE)
13
FT1020G3 Specifications
13
Table 2 Control Unit Specifications
13
FT1020G3 Limitations
14
Table 3 Control Unit Limitations
14
FT1020G3 FDCIE Layout
15
Figure 2 FT1020G3 Control Unit with Printer and Options
15
Front Display
16
Figure 3 FT1020G3 Front Display
16
Fire Brigade Panel Display and Control
17
Table 4 LED Indicators and Push Buttons on Fire Brigade Panel (FBP)
17
FT1020G3 Display CP Indicators
18
Table 5 LED Indicators on Control Panel (CP)
18
Areas in the Display
19
Table 6 Push Buttons / Keypad on Control Panel (CP)
19
Information Area Priority Order
20
Symbol Area
20
Table 7 Symbol Indications
20
Table 8: Priority Order
20
System Information in the LCD
21
4 Control Unit Options
22
I/O Matrix 4582
22
AS1668 Fan Control Module
22
Figure 4 AS1668 Fire Fan Control Display
22
Zone Control & Indication Module
23
Table 9 Indicators and Buttons in AS1668 Module
23
NZ Fire Brigade (LED) MIMIC Board
24
Figure 5 Zone Disable and Indications
24
Table 10 Zone Control Leds and Buttons
24
Occupant Warning System (OWS)
25
Figure 6 NZ Fire Brigade MIMIC Sample Drawing
25
Figure 7 Occupant Warning System Display
25
Gaseous Extinguishing Control Module
26
Figure 8 Gas Extinguishing Display Layout
26
Table 11 OWS Controls and Indications
26
Table 12 Gas Front Status LED Indication and Flash Pattern
27
5 New 19" Rack Cabinet & New Loop Modules
28
Cabinet Overview
28
Figure 9 FT1020G3 Mounted in Large 19" Rack Enclosure
28
Enclosure Components
29
Addressable COM Loop Display Modules
29
Figure 10 3U Ancillary Modules Face Plate (CB681)
29
Figure 11: 1204 Power Monitor Module
30
Figure 12: 1205 Zone Control Module
30
Figure 13: 1206 Fan Control Module
30
Figure 14: 1211 Damper Control Module
30
Figure 15: 1207- 8 Key/ 8 LED Control & Display Module
30
Figure 16: 1208 - 4 Key/ 8 LED Control and Display Module
30
Figure 17: 1209 - 8 LED Display Module
30
Figure 18: 1210 - 6 LED Pump Status Module
30
I/O Field Modules
31
Figure 19 SUB997 Single Supervised Input / Single Relay Output
33
Figure 20 SUB983 4 Supervised Input / 4 Supervised 24V Output
33
Figure 21 SUB994 Four Supervised Inputs / Four Latching Relay Outputs
33
Figure 22 SUB991 8 Non-Supervised Input / 8 Relay Output
33
Figure 23 Field Module Enclosure BAFMES
33
6 User Data & Access Levels
34
User Data
34
Access Levels
35
User Level
36
Table 13 Levels of Access
36
Table 14: Access Levels and User Names
36
Passwords / Change of Password
39
7 Technical Address / Presentation Number
40
Technical Address for COM Loop Units
40
Presentation Number
40
8 Silence Alarm Devices
41
SILENCE ALARM (Inside Switch)
41
NZ FB "Silence Alarms" Bulgin Key (Outside Switch)
42
Isolated Alarm
43
9 Disable / Re-Enable Alarm Devices
44
10 "Silence Buzzer
45
Silence Buzzer by Open Door
45
Silence Buzzer by the "FB Bulgin Key
45
Buzzer
45
11 Disable or Re-Enable Output
46
12 Disable/Re-Enable Control Outputs
47
13 "DISABLE" Button
48
14 Open Door
49
Disable Routing Equipment with Door Switch
49
Silence Buzzer by Door Switch
49
15 Alarm Types
50
Pre-Warning
50
Fire Alarm
51
Heavy Smoke Alarm / Heavy Heat Alarm
54
Alert Annunciation Alarm (AA Alarm)
54
Co-Incidence Alarm (2-Address / -Zone Dependence)
55
Delayed Alarm
56
Alarm Acknowledgement Facility (AAF)
57
Quiet Alarm
58
Acknowledged and Isolated Alarm
59
16 Alarm Reset
60
Pre-Warning Reset
60
Fire Alarm Reset
60
Test Mode Alarm Reset
61
Acknowledged and Isolated Alarm (for Only NZ) Reset
61
Heavy Smoke / Heat Alarm Reset
61
Alert Annunciation Alarm Reset
61
Co-Incidence Alarm
61
Delayed Alarm
61
Local Alarm Acknowledgement (LAA) Reset
62
Quiet Alarm Reset
62
17 Fault
63
Fault Messages
64
Fault Acknowledge
75
18 Commissioning an FT1020G3
77
General
77
Single Control Unit
77
Control Units in a TLON Network
78
Upgrade Number of Alarm Points
80
19 Software Download
82
Eblwin Software Installation
82
Download SSD
83
Figure 24 Installing Haspusersetup in Compatibility Mode
83
Download Software (System Firmware)
86
Software Versions
89
Table 15 Latest Software Versions for FT1020G3
89
20 Restart
90
Safe Shut down
90
Restart Table
90
Table 16 Data Affected by Restart
90
During Restart
91
21 Perform Monthly Test (H1)
93
22 Disable or Re-Enable (H2)
95
Zone or Zone Address (H2/B1)
96
Output (H2/B2)
98
Output Type (H2/B3)
100
Alarm Devices (H2/B4)
102
Routing Equipment (H2/B5)
104
Alert Annunciation (H2/B6)
106
23 Set Calendar and Clock (H3)
108
Daylight Saving Time
108
24 Present System Status (H4)
109
Disablement (H4/U1)
109
Disablement by Time Channel (H4/U2)
110
Open Doors (H4/U3)
111
Sensor Values (H4/U4)
112
Table 17 Algorithms and Abbreviations in Normal Mode
113
Table 18 Algorithms for 4400 in Advanced Mode
114
Table 19 Algorithms for 4401 in Advanced Mode
114
Sensors Activating SERVICE Signal (H4/U5)
115
Technical Warning (H4/U6)
116
Event Log (H4/U7)
117
Information (H4/U8)
118
25 Service (H5)
119
Calibration of Supervised Outputs (H5/A1)
120
Sensitive Fault Detection Mode (H5/A2)
121
Service Mode for COM-Loop (H5/A3)
122
Display Current Consumption in Unit (H5/A4)
123
Display Current Consumption COM-Loop (H5/A5)
124
Display Statistics for Communication (H5/A6)
125
Activate Address Setting Mode for du (H5/A7)
126
Setup Wireless Detectors (H5/A8)
127
SSD Information (H5/A9)
129
26 FAULT Acknowledge (H6)
130
27 Perform Zone Test (Test Mode) (H7)
131
28 Maintenance (H8)
133
Disconnect / Reconnect Loop / Zone Line Input (H8/S1)
133
Acknowledge SERVICE Signal (H8/S2)
135
Clear Weekly Average (H8/S3)
136
Test of Alarm Devices (H8/S4)
137
Safe Shut down of Control Unit (H8/S5)
138
Activate Address in Alarm Mode (H8/S6)
140
Synchronise the Control Units (H8/S7)
141
Activate / Reset Outputs (H8/S8)
143
29 Interlocking Outputs and Inputs (H9)
145
Activated Interlocking Outputs / Inputs (H9/C1)
145
Activate / Deactivate Interlocking Output (H9/C2)
146
Disable / Re-Enable Interlocking Output (H9/C3)
147
30 Change Password (H10)
148
31 FDCIE Maintenance
149
Replacing Printer Paper
149
Replacing a TLON Connection Board And/Or the Main Board
150
Battery Maintenance
150
32 How to Avoid Nuisance Fire Alarms
151
33 Block Wiring Diagram
153
Table 20 Other Drawing Lists
153
Figure 25 Standard FT1020G3 General Arrangement
154
Figure 26 19" Rack FT1020G3 General Arrangement
155
Figure 27 FT1020G3 Block Wiring Overview
156
Figure 28 FT1020G3 Standard Block Wiring Diagram
157
34 Guarantee
158
35 Revision History
159
Operation Manual Revisions Table
159
Software Revision 2.4.4
159
Advertisement
Brooks firetracker FT1020G3 FDCIE Quick Operation Manual (6 pages)
Brand:
Brooks
| Category:
Control Panel
| Size: 0.31 MB
Advertisement
Related Products
Brooks Firetracker FT1-SB
Brooks Firetracker FT420
Brooks Firetracker FT128 CIE
Brooks FireTracker FT2GAS
Brooks FPD 400
Brooks FPD 700
Brooks FAC20
Brooks FluidX Scope USB
Brooks FluidX Aperio Series
Brooks FluidX Aperio 8
Brooks Categories
Measuring Instruments
Controller
Laboratory Equipment
Security System
Smoke Alarm
More Brooks Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL