Manuals and User Guides for Binder MKT E5 Series. We have
1
Binder MKT E5 Series manual available for free PDF download: Operating Manual
Binder MKT E5 Series Operating Manual (159 pages)
Alternating climate chambers with program control; Alternating climate chambers with deep temperature and program control
Brand:
Binder
| Category:
Climate chamber
| Size: 10 MB
Table of Contents
Table of Contents
2
1 Safety
6
Legal Considerations
6
Structure of the Safety Instructions
6
Signal Word Panel
6
Safety Alert Symbol
7
Pictograms
7
Word Message Panel Structure
8
Localization / Position of Safety Labels on the Chamber
8
Type Plate
9
General Safety Instructions on Installing and Operating the Chamber
10
Intended Use
12
Operating Instructions
13
Measures to Prevent Accidents
13
2 Chamber Description
14
Chamber Overview
15
Instrument Panel
15
Lateral Control Panel
16
Main Power Switch (MK 56)
17
Rear Power Switch (MK / MKT 115, 240, 720)
17
Rear Chamber View
18
3 Completeness of Delivery, Transportation, Storage, and Installation
20
Unpacking, and Checking Equipment and Completeness of Delivery
20
Guidelines for Safe Lifting and Transportation
21
Storage
21
Location of Installation and Ambient Conditions
21
4 Installation and Connections
23
Connection of Cooling Water Outlet for Water Cooling (Option for MK 56)
23
Connection of Cooling Water Inlet for Water Cooling (Option for MK 56)
23
Installation of the Voltage and Frequency Changer (Chambers with Voltage and Frequency Changer)
24
Electrical Connection
26
Information on Connecting the Alternating Climate Chamber
26
Connecting the Voltage and Frequency Changer (for Chambers Equipped with a Voltage and Frequency Changer)
27
5 Functional Overview of the Mb2 Chamber Controller
28
Operating Functions in Normal Display
29
Display Views: Normal Display, Program Display, Chart-Recorder Display
30
Controller Icons Overview
31
Operating Modes
33
Controller Menu Structure
34
Main Menu
35
Settings" Submenu
36
Service" Submenu
36
Principle of Controller Entries
37
Performance During and after Power Failures
37
Performance When Opening the Door
38
6 Start up
38
Turning on the Chamber
38
Controller Settings Upon Start up
39
7 Set-Point Entry in "Fixed Value" Operating Mode
40
Set-Point Entry through the "Setpoints" Menu
40
Direct Setpoint Entry Via Normal Display
41
Special Controller Functions Via Operation Lines
41
8 Timer Program: Stopwatch Function
43
Starting a Timer Program
43
Performance During Program Delay Time
43
Stopping a Running Timer Program
44
Pausing a Running Timer Program
44
Cancelling a Running Timer Program
44
Performance after the End of the Program
44
9 Time Programs
45
Starting an Existing Time Program
45
Performance During Program Delay Time
46
Stopping a Running Time Program
46
Pausing a Running Time Program
46
Cancelling a Running Time Program
46
Performance after the End of the Program
46
Creating a New Time Program
47
Program Editor: Program Management
47
Deleting a Time Program
48
Section Editor: Section Management
49
Add a New Program Section
50
Copy and Insert or Replace a Program Section
50
Deleting a Program Section
51
Value Entry for a Program Section
52
Section Duration
52
Set-Point Ramp and Set-Point Step
53
Special Controller Functions Via Operation Lines
54
Setpoint Entry
55
Tolerance Range
56
Repeating One or Several Sections Within a Time Program
57
Saving the Time Program
57
10 Week Programs
58
Starting an Existing Week Program
58
Cancelling a Running Week Program
58
Creating a New Week Program
59
Program Editor: Program Management
60
Deleting a Week Program
61
Section Editor: Section Management
62
Add a New Program Section
63
Copy and Insert or Replace a Program Section
63
Deleting a Program Section
64
Value Entry for a Program Section
64
Set-Point Ramp and Set-Point Step Modes
64
Weekday
65
Start Time
65
Setpoint Entry
66
Special Controller Functions Via Operation Lines
66
11 Notification and Alarm Functions
67
Notification and Alarm Messages Overview
67
Notifications
67
Alarm Messages
68
State of Alarm
68
Resetting an Alarm, List of Active Alarms
69
Activating / Deactivating the Audible Alarm (Alarm Buzzer)
69
12 Temperature Safety Devices
70
Over Temperature Protective Device (Class 1)
70
Overtemperature Safety Controller Class 2
70
Safety Controller Modes
70
Setting the Safety Controller
71
Message and Measures in the State of Alarm
72
Function Check
72
Over/Under Temperature Safety Device Class 2 (Option)
73
13 User Management
74
Authorization Levels and Password Protection
74
Log in
77
Log out
78
User Change
78
Password Assignment and Password Change
79
Password Change
79
Deleting the Password for an Individual Authorization Level
81
New Password Assignment for "Service" or "Admin" Authorization Level When the Password Function was Deactivated
82
Activation Code
83
14 General Controller Settings
84
Selecting the Controller's Menu Language
84
Setting Date and Time
84
Selecting the Temperature Unit
86
Display Configuration
86
Adapting the Display Parameters
86
Touchscreen Calibration
87
Network and Communication
88
Serial Interfaces
88
Ethernet
89
Configuration
89
Display of MAC Address
90
Web Server
90
E-Mail
91
USB Menu: Data Transfer Via USB Interface
92
Turning off the Interior Lighting Automatically
93
15 General Information
93
Service Contact Page
93
Current Operating Parameters
94
Event List
95
Technical Chamber Information
95
Self-Test Function (MK 56)
96
16 Chart Recorder Display
98
Views
98
Show and Hide Legend
98
Switch between Legend
98
Show and Hide Specific Indications
99
History Display
99
Setting the Parameters
102
17 Notes on Refrigerating Operation
103
18 Anti-Condensation Protection Via Operation Line
104
19 Zero-Voltage Switching Outputs Via Operation Lines
105
20 Options
106
APT-COM™ 4 Multi Management Software (Option)
106
RS485 Interface (Option)
106
Data Logger Kit (Option)
106
Analog Outputs for Temperature (Option)
106
Compressed Air Connection (Option)
107
Compressed Air Dryer (Option)
107
Water Cooling (Option)
109
Object Temperature Display with Flexible Pt 100 Temperature Sensor (Option)
109
21 Maintenance, Cleaning, and Service
110
Maintenance Intervals, Service
110
Cleaning and Decontamination
111
Cleaning
111
Decontamination
113
Sending the Chamber Back to BINDER Gmbh
114
22 Disposal
114
Disposal of the Transport Packing
114
Decommissioning
115
Disposal of the Chamber in the Federal Republic of Germany
115
Disposal of the Chamber in the Member States of the EU Except for the Federal Republic of Germany
116
Disposal of the Chamber in Non-Member States of the EU
117
23 Troubleshooting
118
24 Technical Description
121
Factory Calibration and Adjustment
121
Over-Current Protection
121
Definition of Usable Volume
121
MK (E4) Technical Data
122
MKT (E4) Technical Data
124
Equipment and Options (Extract)
126
Accessories and Spare Parts (Extract)
127
MK Heating-Up and Cooling-Down Graphs
128
MKT Heating-Up and Cooling-Down Graphs
132
MK Heat Compensation
135
MKT Heat Compensation
136
Dimensions
138
25 Certificates and Declarations of Conformity
143
EU Declaration of Conformity for MK
143
EU Declaration of Conformity for MKT
146
Certificate for the GS Mark of Conformity of the "Deutsche Gesetzliche Unfallversicherung E.V." (German Social Accident Insurance) DGUV
149
26 Product Registration
151
Registering a BINDER Chamber
151
Multi Management Software APT-COM™ 4 BASIC-Edition
152
27 Contamination Clearance Certificate
153
For Chambers Located Outside the USA and Canada
153
For Chambers Located in the USA and Canada
156
Advertisement
Advertisement
Related Products
Binder MKT Series
Binder MK Series
Binder MKF
Binder MKF056-230V
Binder MKF115-400V-C
Binder MKF720-400V
Binder MKF720-400V-C
Binder MKFT115-400V-C
Binder MK 400
Binder MK 1020
Binder Categories
Laboratory Equipment
Climate chamber
Accessories
Oven
Media Converter
More Binder Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL