Sign In
Upload
Manuals
Brands
Binder Manuals
Farm Equipment
CB UL Series
Binder CB UL Series Manuals
Manuals and User Guides for Binder CB UL Series. We have
1
Binder CB UL Series manual available for free PDF download: Operating Manual
Binder CB UL Series Operating Manual (175 pages)
CB (E7), CO2 Incubators, CO2 Incubators with O2 Control, CO2 Incubators with Active Humidification. With sterilizable NDIR sensor system for CO2 and microprocessor program controller MB2
Brand:
Binder
| Category:
Accessories
| Size: 8 MB
Table of Contents
Table of Contents
2
Safety
7
Legal Considerations
7
Structure of the Safety Instructions
7
Signal Word Panel
7
Safety Alert Symbol
8
Pictograms
8
Word Message Panel Structure
9
Localization / Position of Safety Labels on the Chamber
10
Type Plate
11
General Safety Instructions on Installing and Operating the CO Incubator
12
Precautions When Working with Gases
13
Precautions When Handling Gas Cylinders
15
Intended Use
16
Measures to Prevent Accidents
17
Resistance of the Humidity Sensor against Harmful Substances
18
Chamber Description
19
Chamber Overview
20
Inner Chamber
21
Control Panel on the Rear of the Chamber
22
3 Completeness of Delivery, Transportation, Storage, and
23
Instrument Panel
23
Installation
23
Unpacking, and Checking Equipment and Completeness of Delivery
23
Guidelines for Safe Lifting and Transportation
24
Storage
24
Location of Installation and Ambient Conditions
25
Installation and Connections
28
Shelves
28
Permadry™ Water Pan
28
Connecting the O
29
Control)
29
Gas Connections
30
Connection of the CO Gas Cylinder
31
Connection of the O Gas Cylinder (Chamber with O Control with Optional Alternative Control Range 10 up to 95 Vol.-% O )
32
Connection of the N
33
Control)
33
Connecting the Gas Hose to the Chamber Rear (for CO )
34
Gas Cylinder Connection Kits (Option)
35
Water Supply for the Chamber with Active Humidification
36
Types of Suitable Water Quality
36
Water Supply Installation
37
BINDER Pure Aqua Service (Option)
37
Electrical Connection
38
Handling and Aligning the Divided Inner Door, Gas Proof (Optional Equipment)
39
Functional Overview of the Mb2 Chamber Controller
40
Operating Functions in Normal Display
41
Display Views: Normal Display, Program Display, Chart-Recorder Display
42
Controller Icons Overview
43
Operating Modes
45
Controller Menu Structure
46
Main Menu
47
Settings" Submenu
48
Service" Submenu
48
Principle of Controller Entries
49
Performance During and after Power Failures
49
Performance When Opening the Door
50
Start up
50
Turning on the Chamber
50
Controller Settings Upon Start up
51
Entering the Altitude of the Installation Site
52
Factory Settings
52
Equilibration Time
53
Operating the Duodoor™ Door Lock
53
Required Gas Supply for the Chamber with O
54
Alternative Control Range 10 Vol.-% up to 95 Vol.-% (Option)
54
Hypoxic Control Range 0.2 Vol.-% up to 20 Vol.- % O (Regular)
54
Control
54
Operation Without O Control
54
Activating / Deactivating CO and Humidity Control
55
Humidity Control of the Permadry™ System
56
Set-Point Entry in "Fixed Value" Operating Mode
57
Set-Point Entry through the "Setpoints" Menu
58
Direct Setpoint Entry Via Normal Display
59
Special Controller Functions Via Operation Lines
60
Safety Instructions for Setting High Gas Concentrations
61
Timer Program: Stopwatch Function
62
Starting a Timer Program
62
Performance During Program Delay Time
62
Stopping a Running Timer Program
63
Pausing a Running Timer Program
63
Cancelling a Running Timer Program
63
Performance after the End of the Program
63
Time Programs
64
Starting an Existing Time Program
64
Performance During Program Delay Time
65
Stopping a Running Time Program
65
Pausing a Running Time Program
65
Cancelling a Running Time Program
65
Performance after the End of the Program
65
Creating a New Time Program
66
Program Editor: Program Management
66
Deleting a Time Program
67
Section Editor: Section Management
68
Add a New Program Section
69
Copy and Insert or Replace a Program Section
69
Deleting a Program Section
70
Value Entry for a Program Section
71
Section Duration
71
Set-Point Ramp and Set-Point Step
72
Special Controller Functions Via Operation Lines
74
Setpoint Entry
75
Tolerance Range
75
Repeating One or Several Sections Within a Time Program
76
Saving the Time Program
77
Week Programs
78
Starting an Existing Week Program
78
Cancelling a Running Week Program
78
Creating a New Week Program
79
Program Editor: Program Management
80
Deleting a Week Program
81
Section Editor: Section Management
82
Add a New Program Section
83
Copy and Insert or Replace a Program Section
83
Deleting a Program Section
84
Value Entry for a Program Section
84
Set-Point Ramp and Set-Point Step Modes
84
Weekday
85
Start Time
85
Setpoint Entry
86
Special Controller Functions Via Operation Lines
86
Notification and Alarm Functions
87
Notification and Alarm Messages Overview
87
Notifications
87
Alarm Messages
88
State of Alarm
90
Resetting an Alarm, List of Active Alarms
90
Activating / Deactivating the Audible Alarm (Alarm Buzzer)
91
Tolerance Range Settings and Alarm Delay Times
91
Zero-Voltage Relay Alarm Output
93
Temperature Safety Devices
94
Over Temperature Protective Device (Class 1)
94
Overtemperature Safety Controller Class 3.1
94
Safety Controller Modes
95
Setting the Safety Controller
95
Message and Measures in the State of Alarm
96
Function Check
96
User Management
97
Authorization Levels and Password Protection
97
Log in
100
Log out
101
User Change
101
Password Assignment and Password Change
102
Password Change
102
Deleting the Password for an Individual Authorization Level
104
New Password Assignment for "Service" or "Admin" Authorization Level When the Password Function was Deactivated
105
Activation Code
106
General Controller Settings
107
Selecting the Controller's Menu Language
107
Setting Date and Time
107
Selecting the Temperature Unit
109
Display Configuration
109
Adapting the Display Parameters
109
Touchscreen Calibration
110
Network and Communication
111
Serial RS485 Interface (Available Via BINDER INDIVIDUAL Customized Solutions)
111
Ethernet
112
Configuration
112
Display of MAC Address
113
Web Server
113
E-Mail
114
USB Menu: Data Transfer Via USB Interface
115
General Information
116
Service Contact Page
116
Current Operating Parameters
116
Event List
117
Technical Chamber Information
117
Chart Recorder Display
118
Views
118
Show and Hide Legend
118
Switch between Legend
118
Show and Hide Specific Indications
119
History Display
119
Setting the Parameters
122
Humidification System (Chamber with Active Humidification)
123
Function of the Humidifying System
123
Options
124
Communication Software APT-COM™ 3 Datacontrolsystem (Option)
124
Silicone Access Ports 30 MM / 1.18 In, Closable from both Sides with Silicon Plugs (Option)
124
Interior Socket 230V (Option, Available Via BINDER INDIVIDUAL Customized Solutions)
125
Analog Outputs for Temperature and CO
127
Data Logger Kits (Option)
127
Access Port for Extra-Low Voltage (Option)
128
BINDER Gas Supply Service - External Bottle Changer for CO
129
Stands
129
Stacking Stand (Option)
129
Stacking Adapter for Direct Thermal Decoupled Stacking (Option)
129
Base on Castors (Option)
130
Reference Measurements
130
CO Reference Measuring
130
Measuring CO
130
Concentration Indirectly Via the Ph of the Cell Medium
130
Measuring CO
131
Directly Via Chemical Indicator Tubes
131
Directly with an Electronic Infrared Measuring Device
131
Temperature Reference Measurement
131
Avoiding Microbial Contamination
132
Cells and Media
132
Laboratory Conditions / Equipment Around the Incubator
132
Working and Behavior in the Lab
132
Chamber Design and Equipment of the CO
133
Incubator
133
Handling the CO Incubator
134
Cleaning, Decontamination / Disinfection, and Sterilization
135
Cleaning
135
Decontamination / Chemical Disinfection of the Chamber
137
Hot-Air Sterilization at 180 °C / 356 °F
138
Overview
138
Preparation for a Hot-Air Sterilization
139
Starting the Sterilization Cycle and Running the Hot-Air Sterilization
140
Prematurely Terminating the Sterilization Cycle
141
Prematurely Terminating the Sterilization Cycle after Less than 4 Hours: Ineffective Sterilization
142
Prematurely Terminating the Sterilization Cycle after more than 4 Hours, I.e., During the Cooling-Down Phase: Successful Sterilization
142
Completing the Entire Sterilization Cycle
143
Maintenance and Service
144
Maintenance Intervals, Service
144
Checking the Humidity System Fan
145
Gas Inlet Fine Filter
145
Replacing the CO
145
Sensor
145
Sending the Chamber Back to BINDER Gmbh
146
Disposal
147
Disposal of the Transport Packing
147
Outer Chamber Packing
147
Packing Inside the Chamber and Equipment
147
Decommissioning
148
Disposal of the Chamber in the Federal Republic of Germany
148
Disposal of the Chamber in the Member States of the EU Except for the Federal Republic of Germany
149
Disposal of the Chamber in Non-Member States of the EU
150
Troubleshooting
151
General
151
Heating
151
Gas Cylinder Pressure too Low
152
Gas Concentration
154
Sterilization
156
Humidity (Chamber Without Active Humidification)
156
Humidity (Chamber with Active Humidification)
156
Controller
157
Open Door
157
Technical Description
158
Factory Calibration and Adjustment
158
Over Current Protection
158
Definition of Usable Volume
159
CB Technical Data
159
Equipment and Options (Extract)
161
Accessories and Spare Parts (Extract)
163
Important Conversion Data for Non-SI Units
164
Conversion Table for Gas Inlet Pressures, Bar - Psi
164
Dimensions
165
Certificates and Declarations of Conformity
166
EU Declaration of Conformity
166
Product Registration
168
Contamination Clearance Certificate
169
For Chambers Located Outside the USA and Canada
169
For Chambers in the USA and Canada
172
Advertisement
Advertisement
Related Products
Binder CB-UL Series
Binder CB 160
Binder CB 160-UL
Binder CB 170
Binder CB56-230V-O
Binder CB56-120V-O
Binder CBF170-120V-O
Binder CBF 260
Binder CBF260-120V-O 9640-0024
Binder CBF-UL Series
Binder Categories
Climate chamber
Laboratory Equipment
Accessories
Oven
Farm Equipment
More Binder Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL