Sign In
Upload
Manuals
Brands
Binder Manuals
Laboratory Equipment
9640-0001
Binder 9640-0001 Manuals
Manuals and User Guides for Binder 9640-0001. We have
1
Binder 9640-0001 manual available for free PDF download: Operating Manual
Binder 9640-0001 Operating Manual (115 pages)
CO2 Incubator with FPI-sensor system and RD4 controller
Brand:
Binder
| Category:
Laboratory Equipment
| Size: 8 MB
Table of Contents
Table of Contents
2
Safety
6
Personnel Qualification
6
Operating Manual
6
Legal Considerations
6
Intellectual Property
7
Structure of the Safety Instructions in the Operating Manual
7
Signal Word Panel
7
Safety Alert Symbol
8
Pictograms
8
Prohibition Signs
9
Word Message Panel Structure
9
Localization / Position of Safety and Information Labels at the Chamber
9
Type Plate
10
UKCA Label
11
General Safety Instructions on Installing and Operating the Chamber
12
Precautions When Working with CO 2 Gas
13
Precautions When Handling Gas Cylinders
14
Intended Use
14
Foreseeable Misuse
16
Residual Risks
17
Operating Instructions
18
Measures to Prevent Accidents
18
Chamber Description
19
Chamber Overview
20
Inner Chamber
21
Connection Panel on the Rear of the Chamber
22
Chamber Doors
23
Instrument Panel
23
Completeness of Delivery, Transportation, Storage, and Installation
23
Unpacking, and Checking Equipment and Completeness of Delivery
23
Guidelines for Safe Lifting and Transportation
24
Storage
24
Location of Installation and Ambient Conditions
25
Installation and Connections
27
Shelves
27
CO 2 Sensor
27
Connecting the CO
27
Sensor
27
General Notes
27
Water Pan
28
Gas Connection
29
Connecting the CO Gas Cylinder
30
Gas Cylinder Connection Kit (Accessory)
31
Electrical Connection
32
Functional Overview of the Rd4 Chamber Controller
33
Menu Structure of the Controller and Access Levels
34
Performance During and after Power Failures and Shut down
35
Start up
35
Turning on the Chamber
35
Preset Factory Parameters
36
Performance after Turning on the Chamber
36
Altitude of the Installation Site above Sea Level
37
Temperature and Co
38
Set-Point Entry
38
Temperature Set-Point Entry
38
CO 2 Set-Point Entry
38
Placing Samples in the Incubator
39
Setting Special Controller Functions
40
Idle Mode
40
Deactivated CO 2 Control
41
Password
41
Password Request
41
Assign and Modify a Password
42
Assign and Modify the User Password
42
Assign and Modify the Admin Password
42
Temperature Safety Devices
43
Over Temperature Protective Device (Class 1)
43
Overtemperature Safety Controller Class 3.1
43
Setting the Safety Controller Mode
44
Setting the Safety Controller Value
44
Message and Measures in the State of Alarm
45
Safety Controller
45
Function Check
45
General Controller Settings
46
Selecting the Controller's Menu Language
46
Selecting the Temperature Unit
46
Setting the Current Date
47
Setting the Current Time
48
Function "Language Selection at Restart
48
Setting the Chamber Address
49
Display Brightness
49
Tolerance Range Settings
50
Setting the Delay Time for Tolerance Range Alarm
50
Setting the Temperature Tolerance Range
50
Setting the CO Tolerance Range
51
Setting the Delay Time for Door Open Alarm
51
Chamber Settings (for Experienced Users Only)
52
Setting the Humidity Control
52
Notification and Alarm Functions
52
Alarm Messages
52
Information Messages
54
Activating / Deactivating the Audible Alarm (Alarm Buzzer)
55
Measures in Case of Alarm
55
Door Open Alarm
55
Safety Controller Temperature Alarm
55
Temperature Tolerance Range Alarm (Overtemperature / too Low Temperature)
56
CO Tolerance Range Alarm (CO Over/Under Concentration)
57
CO 2 Pressure Alarm
57
Power Failure Alarm
58
Alarms Referring to Temperature Sensor Failures
59
Alarms Referring to CO Sensor Failure
60
Alarm on Ineffective Sterilization
60
Zero-Voltage Relay Alarm Output
61
Ethernet Network Settings
62
Showing the Network Settings
62
Showing the Chamber's MAC Address
62
Showing the IP Address
62
Showing the Subnet Mask
63
Showing the Standard Gateway
63
Showing the DNS Server Address
63
Showing the DNS Chamber Name
64
Changing the Configuration of the Network Settings
64
Selecting the Type of IP Address Assignment (Automatic / Manual)
64
Selecting the Type of Assignment of the DNS Server Address (Automatic / Manual)
65
Assigning the IP Address
65
Setting the Subnet Mask
66
Setting the Standard Gateway
66
Assigning the DNS Server Address
67
Data Recorder
67
Recorded Data
67
Storage Capacity
68
Setting the Storage Rate for the "DL1" Recorder Data
68
Deleting the Data Recorder
68
Usb Menu: Data Transfer Via Usb Interface
69
Connecting the USB Stick
69
Import Function
69
Import Configuration
69
Export Functions
70
Export Configuration
70
Ongoing Data Transfer
70
Error During Data Transmission
70
Removing the USB Stick
71
Reference Measurements
71
CO Reference Measuring
71
Measuring the CO
71
Concentration Indirectly Via the Ph of the Cell Medium
71
Measuring CO 2 Directly Via Chemical Indicator Tubes
72
Measuring CO Directly with an Electronic Infrared Measuring Device
73
Temperature Reference Measurement
73
Options and Accessories
74
Silicone Access Ports 30 MM / 1.18 In, Closable with 2 Silicone Plugs (8012-0558 Rear, 8012-0559 Left, 8012-0560 Right) (Option)
74
Base on Castors (Accessory)
75
Flat Stacking Frame (Accessory)
75
APT-COM™ 4 Multi Management Software (Accessory)
75
Analog Outputs for Temperature and CO (Option)
75
Avoiding Microbial Contamination
76
Cells and Media
76
Laboratory Conditions / Equipment Around the CO Incubator
76
Working and Behavior in the Lab
76
Chamber Design and Equipment
77
Handling the CO Incubator
78
Cleaning, Decontamination / Disinfection, and Sterilization
79
Cleaning
79
Decontamination / Chemical Disinfection of the Chamber
81
Disinfection of the CO 2 Sensor
82
Hot-Air Sterilization
83
Overview
83
Preparations for Hot-Air Sterilization
83
Starting and Running the Hot-Air Sterilization Cycle
84
Starting Sterilization
84
Performance During Sterilization
85
Completing the Entire Sterilization Cycle
86
Prematurely Terminating the Sterilization Cycle - Effects
86
Premature Termination after Less than 4 Hours: Ineffective Sterilization
86
Premature Termination after more than 4 Hours, I.e., During the Cooling-Down Phase: Successful Sterilization
87
Prematurely Terminating the Sterilization Cycle - Procedure
87
Cancelling Sterilization Via the Controller Menu
87
Opening the Outer Door
88
Turning off the Chamber
88
Maintenance, and Service, Troubleshooting, Repair, Testing
89
General Information, Personnel Qualification
89
Maintenance Intervals, Service
90
Service Reminder
90
Service Due
90
Gas Inlet Fine Filter
91
Simple Troubleshooting
91
General
91
Temperature
92
Co 2
93
Humidity
94
Controller
94
Sterilization
95
Sending the Chamber Back to BINDER Gmbh
95
Disposal
96
Disposal of the Transport Packing
96
Outer Chamber Packing
96
Packing Inside the Chamber, Equipment
96
Decommissioning
97
Disposal of the Chamber in the Federal Republic of Germany
97
Disposal of the Chamber in the Member States of the EU Except for the Federal Republic of Germany
98
Disposal of the Chamber in Non-Member States of the EU
99
Technical Description
100
Factory Calibration and Adjustment
100
Over Current Protection
100
Definition of Usable Volume
100
CB-S / CB-S-UL Technical Data
101
Important Conversion Data for Non-SI Units
102
Conversion Table for Gas Inlet Pressures, Bar - Psi
103
Equipment and Options (Extract)
103
Options, Accessories, and Spare Parts (Extract)
104
Dimensions
105
Certificates and Declarations of Conformity
107
EU Declaration of Conformity
107
UKCA Declaration of Conformity
109
Contamination Clearance Certificate
110
For Chambers Located Outside the USA and Canada
110
For Chambers in the USA and Canada
113
Advertisement
Advertisement
Related Products
Binder 9640-0009
Binder 9640-0008
Binder 9640-0007
Binder 9640-0006
Binder 9640-0005
Binder 9640-0002
Binder 9640-0003
Binder 9640-0004
Binder 9640-0023
Binder 9640-0015
Binder Categories
Climate chamber
Laboratory Equipment
Accessories
Oven
Farm Equipment
More Binder Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL