Sign In
Upload
Manuals
Brands
Binder Manuals
Accessories
9120-0112
Binder 9120-0112 Manuals
Manuals and User Guides for Binder 9120-0112. We have
2
Binder 9120-0112 manuals available for free PDF download: Operating Manual
Binder 9120-0112 Operating Manual (105 pages)
Cooling Incubators with compressor technology and program control
Brand:
Binder
| Category:
Laboratory Equipment
| Size: 11 MB
Table of Contents
Table of Contents
2
Safety
5
Legal Considerations
5
Structure of the Safety Instructions
5
Signal Word Panel
5
Safety Alert Symbol
6
Pictograms
6
Word Message Panel Structure
7
Localization / Position of Safety Labels on the Unit
7
Type Plate
8
General Safety Instructions on Installing and Operating the Cooling Incubator
9
Intended Use
11
Operating Instructions
12
Measures to Prevent Accidents
12
Unit Description
13
Unit Overview
14
Control Panel
15
KB (E5.1) 240 / 400 / 720: Lateral Control Panel at the Right Side (Option)
16
KB (E5.1) 240 / 400 / 720: Lateral Control Panel at the Left Side (Option)
17
Unit Rear
18
Completeness of Delivery, Transportation, Storage, and Installation
18
Unpacking, and Checking Equipment and Completeness of Delivery
18
Guidelines for Safe Lifting and Transportation
19
Storage
19
Location of Installation and Ambient Conditions
20
Installation of the Equipment
21
Spacers for Wall Distance (KB 240, 400, 720)
21
Mounting the Flexible Tilt Protection Kit (KB 400)
22
Electrical Connection
23
Start up
24
Settings at the RD3 Program Controller
24
General Indications
25
Fixed Value Entry Mode
26
Week Program Editor
28
Channel Function
28
Program Table Template for Week Program Editor
30
Program Editor
31
Selecting between Set-Point Ramp and Set-Point Step
31
Programming with Setting "Ramp" (Default Setting)
31
Programming with Setting "Step
33
General Notes on Programming of Temperature Transitions
34
Set-Point Entry for Program Operation
34
Program Table Template for Program Editor
38
Deleting a Program Section
39
Program Start Level
40
User Level
43
Programming Example of the Week Program Editor
50
Desired Time Function
50
Proceeding Overview
50
Proceeding in Detail
51
Programming Example of the Program Editor
57
Desired Time Function
57
Proceeding Overview
57
Proceeding in Detail
58
Performance in Case of Failures
64
Performance after a Power Failure
64
Alarm Messages
64
Temperature Safety Devices
64
Over Temperature Protective Device (Class 1)
64
Safety Controller (Temperature Safety Device Class 3.1)
64
Temperature Safety Device Class 3.3 (Option from Size 53 On)
65
Temperature Safety Device Class 3.1
67
Temperature Safety Device Class 3.2
68
Defrosting During Refrigerating Operation
69
Options
70
Communication Software APT-COM™ 3 Datacontrolsystem (Option)
70
Ethernet Interface (Option for KB 240, 400, 720)
70
Data Logger Kit (Option)
70
Analog Output for Temperature (Option)
71
Water Protected Internal Socket (Option from Size 53 on - Not for KB-UL)
71
Zero-Voltage Relay Outputs Via Operation Lines (Option from Size 53 On)
72
Additional Flexible Pt 100 Temperature Sensor (Option for KB 53, 115)
73
Additional Flexible Pt 100 Temperature Sensor (Option for KB 240, 400, 720)
73
Maintenance, Cleaning, and Service
74
Maintenance Intervals, Service
74
Cleaning and Decontamination
75
Cleaning
75
Decontamination
76
Sending the Unit Back to BINDER Gmbh
77
Disposal
78
Disposal of the Transport Packing
78
Decommissioning
78
Disposal of the Unit in the Federal Republic of Germany
78
Disposal of the Unit in the Member States of the EC Except for the Federal Republic of Germany
79
Disposal of the Unit in Non-Member States of the EC
81
Troubleshooting
82
Technical Description
84
Factory Calibration and Adjustment
84
Over Current Protection
84
Definition of Usable Volume
84
KB (E3.1) Technical Data
85
KB (E5.1) Technical Data
86
Equipment and Options
88
Spare Parts and Accessories
89
Dimensions KB 23
90
Dimensions KB 53
91
Dimensions KB 115
91
Dimensions KB 240
92
Dimensions KB 400
93
Dimensions KB 720
94
Certificates
95
EC Declaration of Conformity
95
Certificate for the GS Mark of Conformity of the "Deutsche Gesetzliche Unfallversicherung E.V." (German Social Accident Insurance) DGUV
97
Product Registration
99
Contamination Clearance Certificate
100
For Units Located Outside North America and Central America
100
For Units in North America and Central America
103
Advertisement
Binder 9120-0112 Operating Manual (85 pages)
Refrigerated incubators with microprocessor program controller RD3, class E3.1
Brand:
Binder
| Category:
Accessories
| Size: 3 MB
Table of Contents
EC - Declaration of Conformity
2
Product Registration
5
Table of Contents
6
1 Safety
8
Legal Considerations
8
Structure of the Safety Instructions
8
Signal Word Panel
8
Safety Alert Symbol
9
Pictograms
9
Word Message Panel Structure
10
Localization / Position of Safety Labels on the Unit
10
Type Plate
11
General Safety Instructions on Installing and Operating the Refrigerated Incubator
12
Intended Use
13
2 Unit Description
14
Unit Overview
15
Instrument Panel
15
3 Completeness of Delivery, Transportation, Storage, and Installation
16
Unpacking, and Checking Equipment and Completeness of Delivery
16
Guidelines for Safe Lifting and Transportation
16
Storage
17
Location of Installation and Ambient Conditions
17
4 Installation of the Equipment
18
Electrical Connection
18
5 Start up
19
Settings at the RD3 Program Controller
19
General Indications
20
6 Fixed Value Entry Mode
21
7 Week Program Editor
23
Program Table Template for Week Program Editor
25
8 Program Editor
26
Selecting between Set-Point Ramp and Set-Point Step
26
Programming with Setting "Ramp" (Default Setting)
26
Programming with Setting "Step
28
General Notes on Programming Temperature Transitions
29
Set-Point Entry for Program Operation
29
Program Table Template for Program Editor
33
Deleting a Program Section
34
9 Program Start Level
35
10 User Level
37
11 Programming Example of the Week Program Editor
45
Desired Time Function
45
Proceeding Overview
45
Proceeding in Detail
45
12 Example Programming for the Program Editor
52
Desired Time Function
52
Proceeding Overview
52
Proceeding in Detail
53
13 Behavior in Case of Failures
59
Behavior after Power Failure
59
Alarm Messages
59
14 Temperature Safety Devices
59
Over Temperature Protective Device (Class 1)
59
Safety Controller (Temperature Safety Device Class 3.1)
59
Temperature Safety Device Class 3.3 (Option from Size 53 On)
59
15 Notes on Refrigerating Operation
62
16 Options
62
Communication Software APT-COM™ 3 Datacontrolsystem (Option)
62
Ethernet Interface (Option)
62
Protocol Printer (Option from Size 53 On)
63
Data Logger Kit
63
Additional Pt100 Temperature Sensor (Option from Size 53 On)
64
Analog Output for Temperature (Option from Size 53 On)
64
Zero-Voltage Relay Outputs Via Operation Lines (Option from Size 53 On)
64
Water Protected Internal Socket (Option from Size 53 On)
65
17 Maintenance, Cleaning, and Service
66
Maintenance Intervals, Service
66
Cleaning and Decontamination
67
Cleaning
67
Decontamination
68
Sending the Unit Back to BINDER Gmbh
69
18 Disposal
70
Disposal of the Transport Packing
70
Decommissioning
70
Disposal of the Unit in the Federal Republic of Germany
70
Disposal of the Unit in the Member States of the EC Except for the Federal Republic of Germany
72
Disposal of the Unit in Non-Member States of the EC
73
19 Troubleshooting
73
20 Technical Description
75
Factory Calibration and Adjustment
75
Over Current Protection
75
Definition of Usable Volume
75
KB Technical Data
76
Equipment and Options
77
Spare Parts and Accessories
78
21 Contamination Clearance Certificate
79
For Units Located Outside North America and Central America
79
For Units in North America and Central America
82
Advertisement
Related Products
Binder 9120-0113
Binder 9120-0114
Binder 9120-0115
Binder 9120-0116
Binder 9120-0117
Binder 9120-0199
Binder 9120-0242
Binder 9120-0302
Binder 9120-0304
Binder 9120-0111
Binder Categories
Climate chamber
Laboratory Equipment
Accessories
Oven
Farm Equipment
More Binder Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL