Sign In
Upload
Manuals
Brands
Berthold Manuals
Measuring Instruments
Universal Monitor II
Berthold Universal Monitor II Dose Rate Manuals
Manuals and User Guides for Berthold Universal Monitor II Dose Rate. We have
1
Berthold Universal Monitor II Dose Rate manual available for free PDF download: User Manual
Berthold Universal Monitor II User Manual (157 pages)
Brand:
Berthold
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
Working with the User's Manual
7
Safety Instructions
9
1 Design and Mode of Operation of the LB134
11
Overview
11
LB 134 Probes
13
Nuclides and Measurement Types
14
Measurement Results as Raw Data and Calculated Units
15
Background Measurement
19
Various Averaging Methods
19
Important Measuring Parameters at a Glance
20
2 System Description
24
Enclosure with Electronics Module
24
Operating and Display Elements
27
Design of the Display
27
Function Keys and Their Meaning
28
Warning Signals
28
Power Supply
29
Working with Batteries
30
Working with Rechargeable Batteries and PSU
30
Power Supply for External Probes
30
Power Supply and Program Memory
30
Data Interface
31
Scope of Delivery
32
Wall Bracket (Optional Accessories)
33
3 Commissioning
35
Connecting the Device
35
The First Control Measurement
36
Basic Parameter Setup
37
Installation of Wall Bracket for Stationary Operation
38
Possible Problems During Commissioning
39
4 Software Design and Operation
40
Software Design
40
Measurement Menu Display
41
Key Functions
44
Labeled Push Buttons and Their Function
44
Softkeys
44
Operation
45
Selecting Menus and Options
45
Editing: Entering Numbers and Letters
45
Selecting Items from a List
46
How to Access the System Menu
46
LED Indicators
47
5 Contamination Measurements
48
Requirements for Contamination Measurements
49
Function Check
49
Measuring and Saving the Background
49
Creating the Small Nuclide Table
52
Importance and Editing the Other Nuclide Parameters
54
Measurement of Contaminations
55
CPS Measurement
56
Measurement of Area Activities
56
Explanations on Raw Data and Calculated Units
58
Measured Result as a Function of the Contaminated Surface
59
Exceeding of Limit Values
60
6 Software Functions
61
Measurement of Contamination, Activity or Doserate
61
Description of the Individual System Menu Items
64
Use Internal DR Detector
65
Background
65
Measurement Mode
69
Measurement Parameters
69
Ratemeter
69
Counter/Timer
71
Search
72
Nuclides/Measurement Types
72
Integral Reset
77
Display Mode
78
Upload and Download Memory and Parameters
79
Parameters
82
Date/Time
82
Language
83
Device Address
83
Calibration Type
83
Light off [Min]
83
Backlight
83
Headphones/Relay
83
Power Supply
84
Hardware
85
Factory Setting
88
Alarm Type
88
Ticks
89
Enable Menus
90
7 Probes for the Lb 134
91
Internal Dose Rate Probe
91
Scintillator Probes with Zns for Contamination Measurements
91
Cleaning the Detector Window of Contamination Probes with Scintillator
93
Changing the Window Foil of Contamination Probes with Scintillator
94
Contamination Probes LB 1231 and LB 1233
96
LB 1233 with Alpha-Beta P10 Counter Tube LB 6359 and Refill Station
98
LB 1231 with Beta-Gamma Counter Tube LB 6357
103
Counter Tube Change
103
Dose Rate Probe LB 1236-H10
104
Neutron Dose Rate Probe LB 6411
106
Neutron Survey Meter LB 6414
107
Nal Scintillation Counter Probe LB 1234
108
Activity Probe for Solid Samples LB 1238
109
Tritium Surface Contamination Monitor
111
Device Configuration
111
Application
112
Probe Assembly
112
Counting Gas Supply
113
Tritium Probe with Trolley
115
Commissioning of Tritium Probe
116
Practical Hints for Operation and Measurement
119
Performance Check
119
Efficiency and Detection Limits
120
Working with the Β-Γ-Probe
122
8 Maintenance
124
Battery Replacement
124
Charging Rechargeable Batteries
125
9 Basis of Calculation
126
Calculating the Count Rate
126
Ratemeter Function
127
Search Mode
128
Counter/Timer Function
129
Determination of Calibration Factors in the Event of Contamination
130
10 Decision Thresholds and Detection Limits
133
11 Appendix
134
Calibration Factors for LB 1342 Scint-Contamination Probe (170 CM²)
134
Calibration Factors for LB 1231 and LB 1233
138
Calibration Factors for LB 1341 (Xenon Detector)
139
Calibration Factors for LB 1343, Scintillation Detector (345 CM²)
141
F²C Communication Protocol and Commands
143
Status Definition in LB 134
143
Transmission Protocol
145
Command Overview
146
Parameter Locking with Jumper J3
152
Pin Assignment of the Fischer Sockets
152
Example of RS485 Network with Multiple LB 134 as Dose Rate Monitor
154
12 Technical Data Lb 134 Umo II
155
13 Index
156
Advertisement
Advertisement
Related Products
Berthold BTwave LB 571-02
Berthold castxpert LB 452
Berthold Duo Series
Berthold DUO XPERT LB 470RID
Berthold Duo Xpert LB 478 MPLM
Berthold DuoXpert LB 476 Level+
Berthold InlineSENS Duo Series
Berthold LB 134
Berthold LB 442
Berthold Categories
Measuring Instruments
Laboratory Equipment
Industrial Equipment
Control Unit
Security Sensors
More Berthold Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL