Uni-Probe LB 490
BERTHOLD TECHNOLOGIES Uni-Probe LB 490 Manuals
Manuals and User Guides for BERTHOLD TECHNOLOGIES Uni-Probe LB 490. We have
1
BERTHOLD TECHNOLOGIES Uni-Probe LB 490 manual available for free PDF download: User Manual
BERTHOLD TECHNOLOGIES Uni-Probe LB 490 User Manual (730 pages)
Process Control, Level Measurement, With All Supplements
Brand:
BERTHOLD TECHNOLOGIES
| Category:
Measuring Instruments
| Size: 33 MB
Table of Contents
Table of Contents
5
About this User's Manual
19
Identification and Warning Messages
19
Further Symbols
20
General Instructions
21
Use and Function
23
Qualification of Personnel
25
Specialized Persons
25
Qualified Persons
26
Authorized Persons
26
Transport and Assembly
27
Electrical Installation
29
Radiation Protection
31
General Information and Guidelines
31
General Radiation Protection Instructions
33
Mounting the Shielding
34
Safety Measures
37
Protection against Theft
37
Accidents, Loss, Damage, Fire, Theft
38
Shielding and Source
40
Leak Test
42
Source Replacement
45
Point Source Replacement
45
Rod Source Replacement
48
Shielding1
49
Radiation Exposure During Source Replacement
55
Source Disposal
57
Functional Safety
61
Scope of Application
61
Use and Function
63
Safety Function
64
Safety Requirement
64
Project Planning
65
Getting Started
67
Behavior During Operation and During Malfunctions
69
Recurrent Performance Test
70
Safety-Technical Data
71
Certificate Functional Safety
73
Safety Instructions for the Types of Protection ATEX / FM / CSA
83
Overview Ex-Versions
85
Type of Protection ATEX
87
Type of Protection FM/CSA
88
Type of Protection CSA
88
Certificates
89
ATEX Certificate
89
FM Certificate
108
CSA Certificate
110
EG Declaration of Conformity
112
Material Safety Data Sheet for Lubricant OKS
113
System Description
119
Measuring System
119
Uni-Probe Hardware
123
Measuring Principle
125
Measuring Arrangements
126
Technical Data
130
Detector Codes
133
Uni-Probe LB 490 Nomenclature
134
LB 490 Super-Sens Nomenclature
135
LB 490 Tower-Sens Nomenclature
136
Installation
139
Transport to the Installation Site
141
Source-Detector Arrangements
143
Detector Protection
145
Detector Installation
147
Mounting the Shielding
160
Electrical Installation
183
Conduits
184
Terminals
187
Switch Setting
189
Connecting the Uni-Probe
192
Uni-Probe with Ex I Current Output
195
Uni-Probe with Signal Output Profibus PA / FOUNDATION
206
Uni-Probe with Intrinsically Safe Signal Output Profibus PA / FOUNDATION
209
Repair, Maintenance and Service
213
General Safety Precautions
213
Visual Inspection of the Uni-Probe
216
Checking the Connection Box
217
Trouble Shooting
218
Replacing the Complete Uni-Probe
220
Replacing the Electronics Module
222
Replacing the Crystal-Multiplier Assembly (for Point Detector)
225
Replacing the Multiplier (for Rod Detector)
227
Fieldbus (Not Intrinsically Safe)
228
Replacing the Plastic Scintillator
229
Replacing the Digital Board
231
Replacing the Power Supply Unit
234
Replacing Fuses
236
Updating the Embedded Software in the Uni-Probe
237
Check Detector
242
Customer Service
245
Returning Repairs
246
Screw Fittings and Accessories
247
ATEX Cable Screw Fittings
247
ATEX-Adapter (Ex D IIC) for Screwed Cable Glands
249
Dummy Plug
249
Technical Drawings
251
Point Detector
251
Rod Detector
254
Super-Sens
264
Tower-Sens
268
Point Source Shielding LB 744X
273
Point Source Shielding for Rod Detectors
281
Rod Source Shielding
282
Pneumatic for Rod and Point Source Shieldings
284
Pneumatic, Design and Electrical Data for Limit Switch
285
Shielding for Rod Source on Dip Tube
286
Flange Adapter for Rod Source Shieldings
287
Cooling Water Curves
289
Point Detectors
289
Rod Detector
289
Super-Sens
291
Tower-Sens
291
Volume 3
296
Hart
297
General Information on the HART ® Communicator
297
Connection, Power on and Power off of the HART Communicator
297
HART ® Communicator
297
Working with the HART Communicator
298
Menu Structure
299
Information on the Menu Structure
299
Menu Overview
300
Start Menu
302
Live Display
303
Probe Raw Data
304
View Parameter
305
Process Variables
305
Show Cal . Curve
306
Status Control
307
Show Error Log
308
Review
309
Access to Setup
311
Enter Password
312
Setup
313
Configuration
313
General Data
314
System Parameter
315
Measure Parameter
316
Damping Data
317
Rad . Interference
319
Pulse Rate Limits
320
Calibration
321
Save
321
Calibration I/O
321
Ave Load Urve
321
Point Curve
323
Multi Point Curve
324
Cal . Point
325
Input / Output
325
Current / Output
326
Digital out Co Nfig
327
Service
328
Test Calculation
329
I/O Test
329
Dig . Output Test
330
Status Dig . Input
330
Current Output
331
Probe Settings
332
Hv Settings
334
Plateau
335
Hart Interface
336
Getting Started Via the HART ® Communicator
337
Steps for Getting Started
337
Setup Protocol
338
Calibration
341
Preparing Calibration
341
Operation Modes for Calibration
348
Two-Point Calibration
350
One-Point Calibration
357
Multi-Point Calibration
360
Functional Processes
367
Plateau Measurement
367
Changing the Uni-Probe Password
369
Set Multi-Detector Mode
371
Explanations
373
Background
373
Conditions for Empty Calibration
375
Linear and Exponential
377
Multi-Point Calibration
380
Radiation Interference Detection
383
Reading-In Pulse Rates
386
Software Versions
388
Error Handling
393
Device Response to Errors
393
Error Handling Modes
394
Corrective Action
395
Reset
397
Operation Modes During Measurement
397
Error Reset
398
Fault Current
399
Setup Protocol
401
Parameter List
401
Calibration Values
402
PC Connection to the Uni-Probe
407
Installing and Working with DTM
409
Requirements
409
FDT Container
409
DTM Communication Software
411
Volume 4
413
SIMATIC PDM User Interface HART
419
Hardware Configuration
421
General Information on SIMATIC PDM
423
Hardware Requirements
424
Fifo Buffer
424
Getting Started with SIMATIC PDM
427
How to Get Started
427
Installing SIMATIC PDM
427
Installing the Uni-Probe LB 490 Device Description
432
Project Setup
434
Start SIMATIC PDM
438
Menu Overview
439
FILE Menu
440
DEVICE Menu
448
VIEW Menu
480
OPTIONS Menu
485
HELP Menu
489
Calibration with SIMATIC PDM
491
Preparing Calibration
491
Operation Modes for Calibration
496
Two-Point Calibration
498
One-Point Calibration
504
Multi-Point Calibration
506
Functional Processes
513
Plateau Measurement
513
Changing the Uni-Probe Password
516
Set Multi-Detector Mode
519
Working with SIMATIC PDM
521
Start SIMATIC PDM
521
The SIMATIC PDM Main Window
522
Device Icons in SIMATIC PDM
525
Explanations
527
Background
527
Conditions for Empty Calibration
529
Linear and Exponential
531
Multi-Point Calibration
534
Radiation Interference Detection
537
Reading-In Pulse Rates
540
Error Handling
543
Device Response to Errors
543
Error Handling Modes
544
Corrective Action
545
Reset
546
Operation Modes During Measurement
547
Error Reset
547
Fault Current
548
1 Process Operation
555
Important Information on the Profibus PA Operation
555
Alternative Operation Via HART
555
System Overview
556
Installation / Program Start
559
Installing the Device Description (DD)
559
Starting SIMATIC PDM
560
Device-Specific Menus
561
DEVICE Tab
562
VIEW Menu
592
Calibration with SIMATIC PDM
601
Preparing Calibration
601
Operation Modes for Calibration
606
Two-Point Calibration
608
One-Point Calibration
615
Multi-Point Calibration
618
Functional Processes
625
Plateau Measurement
625
Set Multi-Detector Mode
630
Explanations
633
Background
633
Conditions for Empty Calibration
635
Linear and Exponential
637
Multi-Point Calibration
640
Radiation Interference Detection
643
Reading-In Pulse Rates
646
Error Handling
649
Device Response to Errors
649
Error Handling Modes
650
Corrective Action
651
Reset
653
Operation Modes During Measurement
653
Foundation
657
Process Operation
659
Important Information on the Operation
659
System Overview
660
Installation / Program Start
663
Installing the Device Description
663
Addressing the Uni-Probe LB 490 Level System
663
Parameter Overview
665
Parameters for the Function Block Transducer
666
Parameters for the Function Blocks Analog Input
671
Calibration with FOUNDATION
673
Preparing Calibration
673
Operation Modes for Calibration
676
Two-Point Calibration
678
One-Point Calibration
682
Multi-Point Calibration
684
Functional Processes
689
Plateau Measurement
689
Multi-Detector Mode
691
Test Calculation (Test Signal Output)
693
Damping
694
Radiation Interference Detection
696
Input Configuration
696
Relay Configuration
697
Defining the Upper/Lower Pulse Rate Limit
698
Protecting Parameters against Modification
699
Reading out the Error Log
699
Explanations
701
Background
701
Conditions for Empty Calibration
703
Linear and Exponential
705
Multi-Point Calibration
708
Error Handling
715
Device Response in Case of Error
715
Error Handling Modes
716
Operation Modes During Measurement
716
Corrective Action
717
Reset
719
Advertisement
Advertisement
Related Products
BERTHOLD TECHNOLOGIES LB 480
BERTHOLD TECHNOLOGIES LB 444
BERTHOLD TECHNOLOGIES LB 124 Scint Series
BERTHOLD TECHNOLOGIES LB 124 Scint SW
BERTHOLD TECHNOLOGIES LB 379
BERTHOLD TECHNOLOGIES LB 3602
BERTHOLD TECHNOLOGIES LB 3603
BERTHOLD TECHNOLOGIES LB 567
BERTHOLD TECHNOLOGIES Junior LB 9509
BERTHOLD TECHNOLOGIES LB4710-050
BERTHOLD TECHNOLOGIES Categories
Measuring Instruments
All in One Printer
Industrial Equipment
Switch
Security Sensors
More BERTHOLD TECHNOLOGIES Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL