Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
Brand:
Bender
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
3
1 General Instructions
7
How to Use this Manual
7
Technical Support: Service and Support
7
Training Courses
8
Delivery Conditions, Warranty and Liability
9
Inspection, Transport and Storage
9
Warranty and Liability
9
Disposal
10
2 Safety Instructions
11
General Safety Instructions
11
Work Activities on Electrical Installations
11
Device-Specific Instructions
12
Intended Use
12
3 Functional Description
13
Measurement Functions
13
Monitoring of Different System Types: 1AC, 3AC, 3NAC
13
Continuous Monitoring of the Phase Voltage and Line-To-Line Voltage
13
Disconnection
14
Re)Connection and Special Reconnections
14
Re)Connection and Monitoring of the Conditions
14
Exceptions of Automatic (Re-)Connection
14
Special Reconnections
14
Protective and Monitoring Functions
15
Voltage Protection Functions U<, U<<, U>> and U
15
Frequency Protection Functions F<, F<<, F>> and F
16
Islanding Detection Df/Dt (ROCOF), Vector Shift Detection
17
Unbalance Detection
18
Monitoring of the Tripping Circuits and Interface Switches by Means of Contact Feedback
18
Remote Trip: Remote Disconnection Via Ripple-Control Receiver
19
Test Function for Checking the Tripping Circuit, the Interface Switch and for Determining the Connection Times
19
Automatic Self Test
20
Other Functions
20
Password Protection
20
Protection against Unauthorised Access - Sealable Enclosure
21
Reset Device to Factory Settings
21
History Memory of the Last 300 Faults with Time Stamp (Real-Time Clock)
21
4 Installation, Connection and Commissioning
23
Unpacking
23
Fuses
23
Installation Instructions
24
Schematic Diagram
24
Dimension Diagram VMD460-NA
25
DIN Rail Mounting
25
Screw Mounting
25
Wiring Diagrams
26
VDE-AR-N 4105:2018 - Basic Program 4105_2
26
Generating Units
28
VDE-AR-N 4110:2018-11 - Basic Program 4110
30
Erec G99, G98, C10/11, Din V Vde V 0126-1-1
32
Basic Programs G98, G99, C10/11, 0126
32
Cei 0-21
34
Details Regarding the Digital Inputs (D1
36
Further Standards
37
Commissioning
39
Tripping Circuit Test by the System Installer
39
5 Operation and Settings
40
User Interface
40
Display Indications
41
Standard Display
41
Info Display
41
Alarm Display
41
Menu Display
42
Toggling between the Individual Displays
42
INFO Button
43
MENU Button
43
Alarm/ Meas. Values
44
History
45
Settings
46
System
46
Info
48
6 Basic Programs
49
Vde-Ar-N 4105:2018-09
51
Vde-Ar-N 4105:2011-08
53
Vde-Ar-N 4110:2018-11
55
BDEW Guideline 2008
57
Din V Vde V 0126-1-1:2006-02/A1:2012-02
59
Cei 0-21(:2012-06, :V1:2012-12, :V2:2013-12, :2014-09, :V1:2014-12; 2016-07, V1:2017-07)
61
G99/1-4:2019
70
G59/2:2010, -1/2011
72
7 Maintenance, Troubleshooting, Messages
74
Recurrent Test of the Tripping Circuit by the System Operator
74
Manual Self Test
74
Messages and Malfunctions
76
Leds
77
8 Technical Data VMD460-NA
78
Standards, Approvals and Certifications
81
Ordering Details
81
Index
83
Advertisement
Bender VMD460-NA Manual (64 pages)
Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
Brand:
Bender
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
1 How to Use this Documentation Effectively
7
How to Use this Manual
7
Technical Support: Service and Support
8
Workshops
9
Delivery Conditions, Guarantee, Warranty and Liability
10
2 Safety
11
Intended Use
11
Electrically Skilled Person
11
General Safety Instructions
12
3 Function
13
Device Features
13
Description of Function
14
Calculating the Average Value of Overvoltage (VDE-AR-N 4105, CEI 0-21, C10/11)
14
Self Test, Automatic
14
Manual Self Test
15
Remote-Trip (RTG / RT1)
15
Malfunction and Messages
16
Delay Times Ton and Toff
17
Password Protection
17
Factory Setting
17
Erasable History Memory
17
Passive Islanding Detection (Df/Dt)
18
4 Installation, Connection and Commissioning
19
Unpacking
19
Back-Up Fuses
19
Notes on Mounting
20
Block Diagram
20
Dimension Diagram VMD460-NA
21
DIN Rail Mounting
21
Screw Mounting
21
Wiring Diagram
22
Vde-Ar-N 4105, Bdew, C10/11
22
Cei 0-21
24
Details Regarding the Digital Inputs (D1
27
Standards, Selectable
27
Commissioning
27
Trigger Circuit Test by the System Erector
28
5 Operation and Configuration
29
Getting to Know the User Interface
29
Various Displays
30
Standard Display
30
Info Display
31
Alarm Display
31
Menu Display
31
Toggling between the Displays
32
INFO Button
33
Menu Button
33
Alarm/Meas. Values
34
History
35
Settings
37
System
38
Info
40
6 Maintenance
41
7 Selectable Default Settings
43
Vde-Ar-N 4105
44
Cei 0-21
46
BDEW-Guideline
49
8 Technical Data VMD460-NA
55
Standards, Approvals and Certifications
59
Ordering Information
59
Index
61
Bender VMD460-NA Quick Start Manual (9 pages)
Network and system protection (NS protection) for monitoringthe network feed-in from generating plants
Brand:
Bender
| Category:
Protection Device
| Size: 1 MB
Table of Contents
Intended Use
2
Installation
2
Safety Instruction
2
Screw Mounting
2
Scope of Delivery
2
Dimensions
2
Application Standards
3
Connections
3
Wiring Diagram VDE-AR-N 4110:2018-11 – Basic Program 4110 (Suggestion)
4
Wiring Diagram EREC G99, G98, C10/11, DIN V VDE V 0126-1-1
4
Operating Elements
5
Navigation
5
Commissioning Steps
6
Menu Structure (MENU)
6
Alarm/Meas. Values
6
History
6
Settings
6
System
6
Info
6
Technical Data
7
Ordering Details
7
Advertisement
Bender VMD460-NA Quick Start Manual (9 pages)
Network and system protection (NS protection) for monitoring the network feed-in from generating plants
Brand:
Bender
| Category:
Protection Device
| Size: 0 MB
Table of Contents
Installation
2
Intended Use
2
Screw Mounting
2
Safety Instruction
2
Application Standards
3
Operating Elements
5
Commissioning Steps
6
Technical Data
7
Measuring Circuit
7
EU Declaration of Conformity
8
Advertisement
Related Products
bender LINETRAXX VMD461
Bender VMD420
Bender VMD420-DM
Bender VMD420-DM-1
Bender VMD420-DM-2
Bender VMD423H
Bender VMD423H-D-3
Bender VMD423
Bender VMD423-D-1
Bender VMD423-D-2
Bender Categories
Measuring Instruments
Monitor
Control Unit
Control Panel
Relays
More Bender Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL