Aesculap Ennovate SZ387R
B. Braun Aesculap Ennovate SZ387R Manuals
Manuals and User Guides for B. Braun Aesculap Ennovate SZ387R. We have
1
B. Braun Aesculap Ennovate SZ387R manual available for free PDF download: Instructions For Use Manual
B. Braun Aesculap Ennovate SZ387R Instructions For Use Manual (67 pages)
Instruments for MIS access
Brand:
B. Braun
| Category:
Medical Equipment
| Size: 13 MB
Table of Contents
Table of Contents
4
About this Document
5
Scope
5
Warnings
5
Clinical Application
6
Areas of Application and Restrictions on Use
6
Intended Purpose
6
Indications
6
Absolute Contraindications
6
Relative Contraindications
6
Safety Instructions
6
Clinical User
6
Product
6
Sterility
6
Safe Operation
7
Place K-Wire
7
Place K-Wire with Bone Access Needle SZ364SU
7
Place K-Wire with K-Wire Targeting Device (SZ365R and SZ366R)
8
Perform Skin Incision with Skin Incision Guide SZ371R
8
Perform Dilation with Dilator SZ372T to SZ374T and Dilator
8
Handle SZ375T
8
Enlarge Pedicle Canal with Pedicle Probe SZ376R
9
Cut Thread with Screw Tap SZ254R to SZ260R (Optional)
9
Determine Screw Length with Screw Length Measuring Device
10
Sz377R
10
Couple Downtube SZ378R/SZ405R to Pedicle Screw
10
Screw in Pedicle Screw
10
Screw in Pedicle Screw with Screwdriver SZ381R
10
Screw in Fenestrated Pedicle Screw with Injection Cannula SR138SU and Cannula Sleeve SR139R and Fix with Bone Cement
11
Determine Rod Length with Rod Length Caliper SZ382R
13
Adjust Rod Length with Rod Cutter FW206R
13
Bend Rod with French Rod Bender SZ270R
13
Insert Rod with Rod Inserter SZ384R/SZ385R
14
Verify Rod with Rod Indicator SZ387R
15
Push Rod into Screw Head
15
Push Rod into Screw Head with Quick Rod Pusher SZ397R (Option 1)
15
Push Rod into Screw Head with Rod Pusher SZ389R (Option 2)
15
Insert and Tighten Set Screw with the Insertion Instrument for the Set Screw SZ391R
16
Take up Set Screw
16
Insert and Tighten Set Screw with MIS Quick Rod Pusher SZ397R
17
(Option 1)
17
Insert and Tighten Set Screw with Rod Pusher SZ389R (Option 2)
17
Remove Downtube SZ378R/SZ405R with Removal Key SZ380R
17
Carry out Corrective Measure (Optional)
18
Prepare Distraction/Compression
18
Perform Parallel Distraction/Compression with Parallel Distractor Forceps SZ231R and Parallel Compressor Forceps
18
SZ232R (Option 1)
18
Perform Distraction with Compression/Distraction Device
19
SZ394T (Option 2)
19
Interbody Fusion Management: Distraction/Compression with Alignment Tool SZ399R and Cage Sleeve SZ396R (Optional)
20
Remove Downtube SZ378R/SZ405R
20
Perform Distraction/Compression
21
Recouple Downtube after Cage Implantation
21
Insert Alignment Working Port SZ398P
21
Recouple Downtube SZ378R/SZ405R with Alignment Tool
22
Sz380R
22
Recouple Downtube SZ378R/SZ405R after Accidental Decoupling
23
Couple Alignment Tool SZ399R
23
Recouple Downtube SZ378R/SZ405R
23
Validated Reprocessing Procedure
24
General Safety Instructions
24
General Information
24
Single-Use Products
24
Reusable Products
24
Preparations at the Place of Use
24
Preparation before Cleaning
24
Disassembling
25
Parallel Distractor Forceps SZ231R and Parallel Compressor Forceps SZ232R
25
K-Wire Trocar SZ365R and K-Wire Sleeve SZ366R
25
Skin Incision Guide SZ371R
25
Downtube SZ378R/SZ405R
25
Screwdriver SZ381R
25
Rod Length Measuring Instrument for Short Construction
26
Sz382R
26
Rod Inserter for Short Construction SZ384R
26
Rod Inserter for Long Construction SZ385R
26
Alignment Working Port SZ398P
26
Alignment Tool SZ399R
26
Injection Cannula SR138SU and Cannula Sleeve SR139R
26
Cleaning/Disinfection
27
Product-Specific Safety Notes on the Reprocessing Procedure
27
Validated Cleaning and Disinfection Procedure
27
Manual Cleaning/Disinfection
29
Manual Cleaning with Immersion Disinfection
29
Manual Cleaning with Ultrasound and Immersion Disinfection
30
Mechanical Cleaning/Disinfecting
31
Mechanical Alkaline Cleaning and Thermal Disinfecting
31
Mechanical Cleaning/Disinfection with Manual Pre-Cleaning
32
Manual Pre-Cleaning with a Brush
32
Manual Pre-Cleaning with Ultrasound and Brush
33
Mechanical Alkaline Cleaning and Thermal Disinfecting
33
Inspection
34
Visual Inspection
34
Function Test
34
Assembling
34
Downtube SZ378R/SZ405R
34
Screwdriver SZ381R
34
Rod Length Measuring Instrument for Short Construction
34
Sz382R
34
Rod Inserter for Short Construction SZ384R
34
Rod Inserter for Long Construction SZ385R
35
Alignment Working Port SZ398P
35
Alignment Tool SZ399R
35
Packaging
35
Steam Sterilization
35
Storage
35
Maintenance and Service
35
Technical Service
35
Accessories/Spare Parts
35
Disposal
35
Advertisement
Advertisement
Related Products
B. Braun Aesculap Ennovate SZ380R
B. Braun Aesculap Ennovate SZ381R
B. Braun Aesculap Ennovate SZ382R
B. Braun Aesculap Ennovate SZ384R
B. Braun Aesculap Ennovate SZ385R
B. Braun Aesculap Ennovate SZ388R
B. Braun Aesculap Ennovate SZ389R
B. Braun Aesculap Ennovate SZ370
B. Braun Aesculap Ennovate SZ375T
B. Braun Aesculap Ennovate SZ391R