Sign In
Upload
Manuals
Brands
Axetris Manuals
Gas Detectors
LGD F200P2
Axetris LGD F200P2 Manuals
Manuals and User Guides for Axetris LGD F200P2. We have
1
Axetris LGD F200P2 manual available for free PDF download: Operation And Integration Instructions
Axetris LGD F200P2 Operation And Integration Instructions (61 pages)
Laser Gas Detection
Brand:
Axetris
| Category:
Gas Detectors
| Size: 4 MB
Table of Contents
Table of Contents
8
1 General User Information
10
LGD F200P2 Introduction
10
Technical Data
11
Environmental Conditions
11
Mechanical Characteristics
11
Electrical Characteristics
12
Delivery Check
12
Identifying the Unit
12
2 System Set-Up for Evaluation
12
Operation Conditions, Storage & Transport
12
System Layout and Materials
13
Interfacing for Evaluation
14
Setting up for Lab Evaluation
14
Additional Set-Up for Measurements of Hot Gases (H-Version)
15
Gas Conditioning and Filtering Information
17
Calibration / Calibration Verification / Offset and Span
19
Zeroing and Purging
19
If Air Is Used for the Zeroing Make Sure Your Device Is Not Measuring CO
19
Hundreds Ppm of CO that will Give a Wrong Value for the Offset.housing Purge (Optional)
19
Gas Supply
20
Measurement Range and Precision
20
Measurement Software and Interfacing
21
Installing the Measurement Software
21
Starting the Measurement Software
21
Data Acquisition & Saving Measurement Data to a File
22
Status and Error Codes
23
Sensor Parameters
23
Calibration Adjustment
23
Analog Output Adjustment
24
Adjusting Firmware Integration Time (T90)
25
Diagnostic Mode Switch
25
Laboratory Mode Switch
25
Analog_Switch
25
Cursor Function
26
Relay Alarm Definition
27
Data Logger Software
28
Attaching Multiple Devices to a Single Computer
29
3 Instructions for Lgd System Integration
30
Mechanical Mounting of the Unit
30
Thermal Management of the LGD Analyzer Module
31
Thermal Management of the LGD Analyzer Module @220°C
32
Interfacing for Integration
33
Interfacing and Connectors
33
Load Limitation for the Analog Interface
34
Setting the Alarms
34
Data Transmission Protocol
35
RS232 Serial Settings
35
Overall Communication Structure
35
Timing & RS232-Protocol
37
Measurement Data Format
38
Change of User Parameters
39
Commands
39
Version
39
Stop Measurement (Idle)
40
Ping User Data
40
Configure User Data
42
Save to EEPROM
43
Starting Measurements
43
Status, Error and Failure Response
43
4 Maintenance and Trouble Shooting
45
Maintenance
45
Troubleshooting
46
5 Important Disclaimer / Notice
47
6 FCC Statement
47
Annex
48
Status, Warning and Error Code Listing for Evaluation
48
Status, Warning and Error Code Listing for Integrators/Oems
49
Examples for Analog Output Adjustments
50
Mechanical Dimensions
52
LGD F200P2 Mechanical Dimensions, Ambient Version (A)
52
LGD F200P2 Mechanical Dimensions, Heated Version (H)
54
Advertisement
Advertisement
Related Products
Axetris LGD Compact
Axetris Categories
Gas Detectors
Motherboard
Control Unit
More Axetris Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL