Sign In
Upload
Manuals
Brands
Awite Manuals
Measuring Instruments
AwiECO
Awite AwiECO Manuals
Manuals and User Guides for Awite AwiECO. We have
2
Awite AwiECO manuals available for free PDF download: Original Instruction Manual
Awite AwiECO Original Instruction Manual (75 pages)
GAS ANALYSIS SYSTEM
Brand:
Awite
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
1 Table of Contents
3
2 Preface
6
3 Identification
7
4 Safety Instructions
8
5 Product Description
13
Intended Usage
13
Device Category According to ATEX Classification
14
Device Category Not Intended for Installation in an Ex-Zone
14
Device Category Intended for Installation in an Ex-Zone 2
14
Safety Device for the Monitoring of the Interior Space
15
Description of the Gas Analysis System and Dimensions
15
Ambient Conditions and Limits for Operation and Storage
23
Ambient Temperature
23
Ambient Humidity
23
Installation Height
23
Humidity and Dust
24
Measuring Gas Pressure
24
Measuring Gas, Fresh Air and Exhaust Air Requirements
24
Calibration Gas Connection
25
Hazards from Gas
25
Zone Division
26
Flame or Explosion Propagation over Gas Bearing Lines
26
Leakage in the Measuring Gas Supply Line
26
Gas Volume
26
Leaks in the Gas Analysis System
27
Release of Potentially Toxic and Harmful Gases
28
6 Preparing the Gas Analysis System for Use
29
Transport and Storage
29
Installation
29
Main Switch Mains Disconnection Facility
30
Terminal Boxes for Electrical Connections
31
Terminal Box Awiflex Cool+ and Awiflex Cool+ XL
32
Terminal Box Awieco
33
Connection Cable 100-240 V for Power Supply
34
Connection Cable for DI (Digital Inputs) and DO (Digital Outputs)
34
Connection Cable AI (Analogue Inputs) and AO (Analogue Outputs)
34
Potential Equalization
34
Data Transmission Signals
35
Profibus
35
Analogue Outputs
36
Information on Cable and Lines Routing
36
Connection of Analysis Gas Lines
36
Gas Inlets Awiflex Cool
37
Gas Inlets Awiflex Cool+ XL
38
Gas Inlets Awieco
39
Awisamplex - Measuring Point Switch-Over
40
Extraction Points for Analysis Gas
42
Laying of Analysis Gas Lines
44
Exhaust Air - Discharge of the Measuring Gas
44
Installation of Humidity and Flow Sensor Awiflow
46
Initial Operation
49
7 Operation of the Gas Analysis System
50
Maintenance
50
Cleaning
51
Calibration
52
Hydrogen Sulphide Filter (Optional)
52
Detonation Flame Arrester
52
Connecting Tubes
52
Condensate Traps
53
Replacing a Fuse
53
Specification Fuse F1 (Input Voltage 100-240 VAC)
53
Specification Fuse F2 (Power Supply Unit Output Voltage 24 VDC)
53
Spare Parts List
54
Disposal
54
Product Liability
54
8 Technical Data and Sensor Accuracy
55
Technical Data
55
Accuracy, Service Life and Calibration of the Sensors
55
9 Awidesulf Combined Package for Microbiological Desulphurization
57
Intended Usage
61
Assumptions for Interpreting
61
Required Space
62
Mechanical Connection
64
Electrical Connection
64
Maintenance
66
10 Awilab Gas Analysis
67
Required Space
68
Mechanical Connection
69
Electrical Connection
69
11 Document and Change History
70
12 Appendix
72
CE Declarations of Conformity
72
CE Declaration of Conformity for Devices Not Intended to be Installed in an Ex-Zone
72
CE Declaration of Conformity for Devices Intended to be Installed in an Ex
73
Zone
73
IEC Declaration of Conformity
74
Certificate TÜV SÜD (UL / CSA 61010-1:2012)
75
Advertisement
Awite AwiECO Original Instruction Manual (44 pages)
Brand:
Awite
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Table of Contents
3
1 Preface
5
2 Identification
6
3 Safety Instructions Part a
7
4 Product Description
10
Intended Usage
10
Device Category According to ATEX Classification
11
Device Category Not Intended for Installation in an Ex-Zone
11
Device Category Intended for Installation in an Ex-Zone 2
11
Safety Device for Monitoring the Interior Space
12
Description of the Gas Analysis System and Dimensions
13
Ambient Conditions and Limits for Operation and Storage
16
Ambient Temperature
16
Ambient Humidity
16
Installation Height
16
Humidity and Dust
16
Measuring Gas Pressure
16
Measuring Gas, Fresh Air and Exhaust Air Requirements
17
Hazards from Gas
17
Zone Division
18
Flame or Explosion Propagation over Gas Bearing Lines
18
Leakage in the Measuring Gas Supply Line
18
Gas Volume
18
Leaks in the Gas Analysis System
18
Release of Potentially Toxic and Harmful Gases
19
5 Preparing the Gas Analysis System for Use
20
Transport and Storage
20
Installation
20
Main Switch Mains Disconnection Facility
21
Terminal Boxes for Electrical Connections
21
Terminal Box Awieco
22
Connection Cable 100-240 V for Power Supply
22
Connection Cable for DI (Digital Inputs) and DO (Digital Outputs)
22
Connection Cable for AI (Analogue Inputs) and AO (Analogue Outputs)
23
Potential Equalization
23
Data Transmission of Signals
24
Profibus
24
Analogue Outputs
25
Information on Cable and Lines Routing
25
Connection of Analysis Gas Lines
26
Gas Inlets Awieco
26
Extraction Points for Analysis Gas
27
Laying of Analysis Gas Lines
28
Exhaust Air - Discharge of the Measuring Gas
28
Installation of Humidity and Flow Sensor Awiflow
30
Initial Operation
32
6 Handling of the Gas Analysis System
33
Maintenance
33
Cleaning
33
Calibration
34
Hydrogen Sulphide Filter
34
Detonation Flame Arrester
34
Connecting Tubes
34
Condensate Traps
35
Replacing a Fuse
35
Specification Fuse F1 (Input Voltage 100-240 VAC)
35
Specification Fuse F2 (Power Supply Unit Output Voltage 24 VDC)
35
Spare Parts List
35
Disposal
36
Product Liability
36
7 Technical Data and Sensor Accuracy
37
Technical Data
37
Accuracy, Service Life and Calibration of the Sensors
37
8 Annex
40
CE Declarations of Conformity
40
Zone
42
CE Declaration of Conformity for Devices Intended to be Installed in an Ex
42
IEC - Conformity Declaration
43
Certificat TÜV SÜD UL - CSA 61010-1-2012
44
Advertisement
Related Products
Awite AwiFLEX Cool+
Awite AwiFLEX Cool+ XL
Awite AwiFLEX XL
Awite AWIFLEX
Awite 10 Series
Awite Categories
Measuring Instruments
Analytical Instruments
More Awite Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL