Manuals and User Guides for Autonics TK4M: TK4S: TK4W. We have
1
Autonics TK4M: TK4S: TK4W manual available for free PDF download: User Manual
Autonics TK4M: TK4S: TK4W User Manual (124 pages)
high accuracy standard temperature controller
Brand:
Autonics
| Category:
Controller
| Size: 8 MB
Table of Contents
Preface
3
User Manual Guide
4
User Manual Symbols
5
Safety Precautions
6
Table of Contents
9
1 Product Introduction
13
Features
13
Components and Accessories
14
Ordering Information
20
Parts Descriptions
22
2 Specifications
25
3 Dimensions
27
4 Connections
33
Precautions for Wiring
35
Sensor Connection
35
Communication Connection
35
5 Preparation and Startup
37
Initial Display When Power on
37
Basic Controls
38
Parameter Setting Sequence
38
Set Value (SV) Setting
38
MV Monitoring and Manual Control
39
Parameter Group
41
Parameter Groups
44
Parameter 1 Group [PAR1]
44
Parameter 2 Group [PAR2]
45
Parameter 3 Group [PAR3]
47
Parameter 4 Group [PAR4]
49
Parameter 5 Group [PAR5]
52
6 Parameter Settings and Functions
55
Input
55
Input Types and Temperature Ranges
55
Input Type [PAR3 → IN-T]
56
Sensor Temperature Unit [PAR3 → UNIT]
56
Analog Input/Scale Value
57
Input Correction [PAR3 → IN-B]
59
Input Digital Filter [PAR3 → Mavf]
59
High/Low-Limit Value of Setting Value(SV) [PAR3 → H-SV/ L-SV]
60
Control Output
61
Control Output Mode [PAR3 → O-FT]
61
MV High/Low-Limit Value Settings [PAR2 → H-MV / L-MV]
66
Ramp Settings [PAR2 → RAMU/ RAMD/ Runt]
67
Auto/Manual Control Settings
69
Output Settings
72
Temperature Control
73
Temperature Control Mode [PAR3 → C-MD]
73
ON/OFF Control [PAR3 → C-MD → ONOF]
74
PID Control [PAR3 → C-MD → PID]
75
Auto-Tuning
77
Alarm Output
79
Alarm Operation [PAR4 → AL-1/AL-2/AL-3]
79
Alarm Output Options [PAR4 → AL!T/AL@T]
81
Alarm SV Settings [PAR1 → AL!L/AL!H/AL@L/AL@H/AL#L/AL#H]
82
Alarm Output Hysteresis [PAR4 → A!HY/A@HY/A#HY]
82
Alarm N.O./N.C. [PAR4 → A!N/A@N/A#N]
83
Alarm Output Delay Settings [PAR4 → A!ON / A!OF/ A@ON / A@OF/ A#ON / A#OF]
84
Loop Break Alarm(LBA) [PAR4 → AL-1/AL-2/AL-3 → LBA]
85
Sensor Break Alarm [PAR4 → AL-1/AL-2/AL-3 → SBA]
87
Heater Burnout Alarm [PAR4 → AL-1/AL-2/AL-3 → HBA]
88
Alarm Output Deactivation [PAR5 → DI-K→ Alre]
89
Alarm Output Examples
90
Analog Transmission
93
Analog Transmission Output Value Settings [PAR4 → Aom1/ Aom2]
93
Transmission Output High/Low-Limit Value Settings [PAR4 → Fsl1/ Fsh1→ Fsl2/ Fsh2]
93
Communication Settings
95
Unit Address Settings [PAR4 → ADRS]
95
BPS (Bits Per Second) Settings [PAR4 → BPS]
95
Communication Parity Bit [PAR4 → PRTY]
96
Communication Stop Bit Settings [PAR4 → STP]
96
Response Wait Time Settings [PAR4→ Rswt]
96
Enable/Disable Communication Write[Par4→ COMW]
97
USB to Serial Communication Connection
97
Additional Features
98
Monitoring
98
Run/Stop [Par1 → R-S]
99
Multi SV
100
Digital Input
101
Error
103
User Level Setting [PAR5 → USER]
104
Lock Settings
104
Parameter Reset [INIT]
105
Password Settings [PAR5 → PWD]
105
7 Setting Group Parameter Description
107
Setting Group [ SV ]
107
MV Monitoring/Manual Control Setting Group [ MV ]
107
Parameter 1 Setting Group [ PAR1 ]
108
Copyright Reserved Autonics Co., Ltd
108
Parameter 2 Setting Group [PAR2 ]
109
Parameter 3 Setting Group [ PAR3 ]
111
Parameter 4 Setting Group [ PAR4 ]
113
Parameter 5 Setting Group [ PAR5 ]
115
Password Entry Parameter
116
Parameter Change Reset Parameters
116
8 Daqmaster
117
Overview
117
Major Features
118
Special Feature for TK Series
120
Parameter Mask
120
User Parameter Group [PARU]
122
Advertisement
Advertisement
Related Products
Autonics TC4Y
Autonics TZ4SP
Autonics TM2-22RB
Autonics TM2-22CB
Autonics TZN4W
Autonics TZN4H
Autonics TZN Series
Autonics TZ Series
Autonics TNZ Series
Autonics TM Series
Autonics Categories
Accessories
Controller
Temperature Controller
Measuring Instruments
Timer
More Autonics Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL